Evaluation of the performance of digital x-ray systems in pelvis radiography

被引:0
作者
Jreije, Antonio [1 ,2 ]
Krynke, Leonid [1 ]
Griciene, Birute [1 ,3 ]
Rimkus, Bernardas [1 ]
Dementaviciene, Jurate [1 ,3 ]
Skovorodko, Kirill [1 ]
机构
[1] Vilnius Univ Hosp Santaros Klin, Vilnius, Lithuania
[2] Kaunas Univ Technol, Dept Phys, Kaunas, Lithuania
[3] Vilnius Univ, Fac Med, Dept Radiol Nucl Med & Med Phys, Vilnius, Lithuania
关键词
digital radiography; pelvis radiography; dose optimization; image quality; anthropomorphic phantom; IMAGE QUALITY ASSESSMENT; CHEST RADIOGRAPHY; OPTIMIZATION; KVP;
D O I
10.1088/1361-6498/ad5d79
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this study was to investigate the performance of eight digital radiography systems and to optimise the dose-image quality relationship for digital pelvis radiography. The study involved eight digital radiography systems used for general examinations at Vilnius University Hospital Santaros Klinikos. An anthropomorphic pelvic phantom (CIRS, US) was used to simulate a patient undergoing clinical pelvis radiography. Dose quantities entrance surface dose, dose area product (DAP) and exposure parameters (kVp, mA, mAs) were measured and the effects on the images were evaluated, considering physical contrast to noise ratio (CNR) and observer-based evaluations as image quality metrics. Increasing the tube voltage by 5 kVp from standard protocol led to a reduction in radiation dose (DAP) by 12%-20% with a slight impact on image quality (CNR decreases by 2%-10%). There was an inter-observer variability in image rating across different equipment (kappa value between 0 and 0.3); however, both observers agreed that increasing kVp up to 85-90 kV had no effect on perceived image quality. The results indicate that optimisation strategies should be tailored specifically for each x-ray system since significant performance differences and wide variations in radiation dose exist across various digital radiography systems used in clinical settings. The use of high kVp can be used for dose optimisation in digital pelvis radiography without compromising image diagnostic accuracy.
引用
收藏
页数:10
相关论文
共 28 条
[1]   Impact of acquisition parameters on dose and image quality optimisation in paediatric pelvis radiography-A phantom study [J].
Ali, Ali Mohammed ;
Hogg, Peter ;
Abuzaid, Mohamed ;
England, Andrew .
EUROPEAN JOURNAL OF RADIOLOGY, 2019, 118 :130-137
[2]   Towards patient dose optimization in digital radiography [J].
Andria, G. ;
Attivissimo, F. ;
Guglielmi, G. ;
Lanzolla, A. M. L. ;
Maiorana, A. ;
Mangiantini, M. .
MEASUREMENT, 2016, 79 :331-338
[3]  
[Anonymous], 1996, ANN ICRP, V26, P1, DOI DOI 10.1016/S0146-6453(00)89195-2
[4]  
[Anonymous], Lithuanian Hygiene Standard HN 78:2009 2009 Quality control requirements and evaluation criteria in medical X-ray diagnostics adopted by the Order No. V-922 by the Minister of Health Care
[5]  
Barba James, 2015, Radiol Technol, V86, P603
[6]   Copper filtration in pediatric digital X-ray imaging: Its impact on image quality and dose [J].
Brosi P. ;
Stuessi A. ;
Verdun F.R. ;
Vock P. ;
Wolf R. .
Radiological Physics and Technology, 2011, 4 (2) :148-155
[7]   Do CEC guidelines under-utilise the full potential of increasing kVp as a dose-reducing tool? [J].
Doherty, P ;
O'Leary, D ;
Brennan, PC .
EUROPEAN RADIOLOGY, 2003, 13 (08) :1992-1999
[8]   Image quality of bedside chest radiographs in intensive care beds with integrated detector tray: A phantom study [J].
Enevoldsen, S. ;
Kusk, M. W. .
RADIOGRAPHY, 2021, 27 (02) :453-458
[9]  
European Commission. European Commission, 1996, Report EUR 16260. L-2985
[10]   Exposure Creep in Computed Radiography: A Longitudinal Study [J].
Gibson, Dale J. ;
Davidson, Robert A. .
ACADEMIC RADIOLOGY, 2012, 19 (04) :458-462