Multi-institutional dose audit in radiotherapy facilities using in-house developed optically stimulated luminescence disc dosimeters

被引:0
|
作者
Kumar, Pradip [1 ,2 ]
Sharma, Sunil Dutt [3 ,4 ]
Dhabekar, Bhushan [3 ,4 ]
Rawat, Narender Singh [3 ,4 ]
Mishra, Devesh Ramdhar [3 ,4 ]
Chaudhari, Suresh [5 ]
Chandola, Rakesh Mohan [6 ]
Routh, Tapan [2 ]
Agrawal, Sadhana [1 ]
机构
[1] Natl Inst Technol, Dept Phys, GE Rd, Raipur 492010, Chhattisgarh, India
[2] Atom Energy Regulatory Board, Directorate Regulatory Inspect, Mumbai, Maharashtra, India
[3] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Mumbai, Maharashtra, India
[4] Homi Bhabha Natl Inst, Mumbai, Maharashtra, India
[5] Apollo Hosp, Dept Radiat Oncol, Navi Mumbai, Maharashtra, India
[6] Pt JNM Med Coll & Hosp, Dept Radiotherapy, Raipur, Chhattisgarh, India
关键词
dose audit; dosimetry; optically stimulated luminescence; radiotherapy; QUALITY-ASSURANCE MEASUREMENTS; SYSTEMS;
D O I
10.4103/jcrt.jcrt_753_21
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim:The aim of this study was to carried out the audit of radiotherapy centers practicing conformal radiotherapy techniques and demonstrate the suitability of this indigenous optically stimulated luminescence (OSL) disc dosimeters in beam quality audit and verification of patient-specific dosimetry in conventional and conformal treatments in radiotherapy.Materials and Methods:Dose audit in conventional and conformal (intensity-modulated radiotherapy and volumetric-modulated arc therapy) radiotherapy techniques was conducted using in-house developed Al2O3:C-based OSL disc dosimeter and commercially available Gafchromic EBT3 film in 6 MV (flat and unflat) photon and 6 and 15 MeV electron beams. OSL disc dosimeter and Gafchromic EBT3 film measured dose values were verified using the ionization chamber measurements.Results:Percentage variations of doses measured by OSL disc dosimeters and EBT3 Gafchromic film for conventional radiotherapy technique were in the range of 0.15%-4.6% and 0.40%-5.45%, respectively, with respect to the treatment planning system calculated dose values. For conformal radiotherapy techniques, the percentage variations of OSL disc and EBT3 film measured doses were in the range of 0.1%-4.9% and 0.3%-5.0%, respectively.Conclusion:The results of this study supported by statistical evidence provided the confidence that indigenously developed Al2O3:C-based OSL disc dosimeters are suitable for dose audit in conventional and advanced radiotherapy techniques.
引用
收藏
页码:S361 / S367
页数:7
相关论文
共 11 条
  • [1] Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters
    Lye, Jessica
    Dunn, Leon
    Kenny, John
    Lehmann, Joerg
    Kron, Tomas
    Oliver, Chris
    Butler, Duncan
    Alves, Andrew
    Johnston, Peter
    Franich, Rick
    Williams, Ivan
    MEDICAL PHYSICS, 2014, 41 (03)
  • [2] Measurement of radiation dose with BeO dosimeters using optically stimulated luminescence technique in radiotherapy
    Sahin, Serdar
    Tanir, A. Gunes
    Meric, Niyazi
    Aydinkarahaliloglu, Ercan
    APPLIED RADIATION AND ISOTOPES, 2015, 103 : 31 - 36
  • [3] In vivo monitoring of total skin electron dose using optically stimulated luminescence dosimeters
    Kairn, Tanya
    Wilks, Rachael
    Yu, Liting
    Lancaster, Craig
    Crowe, Scott B.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (01) : 35 - 40
  • [4] Dosimetry audit in advanced radiotherapy using in-house developed anthropomorphic head & neck phantom
    Kakade, Nitin R.
    Kumar, Rajesh
    Sharma, S. D.
    Sapra, B. K.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (02)
  • [5] Radiation dose measurements of an on-board imager X-ray unit using optically-stimulated luminescence dosimeters
    Leon Smith
    Mamoon Haque
    Johnny Morales
    Robin Hill
    Australasian Physical & Engineering Sciences in Medicine, 2015, 38 : 665 - 669
  • [6] Radiation dose measurements of an on-board imager X-ray unit using optically-stimulated luminescence dosimeters
    Smith, Leon
    Haque, Mamoon
    Morales, Johnny
    Hill, Robin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (04) : 665 - 669
  • [7] Precision In-Vivo Dosimetry Using Optically Stimulated Luminescence Dosimeters and a Pulsed-Stimulating Dose Reader
    Chen, Q.
    Herrick, A.
    Hoke, S.
    Burns, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 498 - 499
  • [8] Multi-channel fibre optic dosimeter based on Optically Stimulated Luminescence for dose verification during radiotherapy treatments
    magne, Sylvain
    Auger, Laureline
    Isambert, Aurelie
    Bridier, Andre
    Ferdinand, Pierre
    Barthe, Jean
    THIRD EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2007, 6619
  • [9] Surface and near-surface dose measurements at beam entry and exit in a 1.5 T MR-Linac using optically stimulated luminescence dosimeters
    Kim, Anthony
    Lim-Reinders, Stephanie
    Ahmad, Syed Bilal
    Sahgal, Arjun
    Keller, Brian M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (04)
  • [10] A multi-institutional study of secondary check of treatment planning using Clarkson-based dose calculation for three-dimensional radiotherapy
    Takahashi, Ryo
    Kamima, Tatsuya
    Itano, Masanobu
    Yamazaki, Takeshi
    Ishibashi, Satoru
    Higuchi, Yoshihiro
    Shimizu, Hiroyuki
    Yamamoto, Toshijiro
    Yamashita, Mikiko
    Baba, Hiromi
    Sugawara, Yasuharu
    Sato, Aya
    Nishiyama, Shiro
    Kawai, Daisuke
    Miyaoka, Satoshi
    Tachibana, Hidenobu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 49 : 19 - 27