Ultrasound-Compatible Electrode for Functional Electrical Stimulation

被引:0
作者
Moon, Sunho [1 ]
Xue, Xiangming [2 ,3 ]
Ganesh, Vidisha [2 ,3 ]
Shukla, Darpan [1 ]
Kreager, Benjamin C. [1 ]
Cai, Qianqian [1 ]
Wu, Huaiyu [1 ]
Zhu, Yong [1 ]
Sharma, Nitin [2 ,3 ]
Jiang, Xiaoning [1 ]
机构
[1] North Carolina State Univ, Dept Mech & Aerosp Engn, Raleigh, NC 27606 USA
[2] North Carolina State Univ, Joint Dept Biomed Engn, Raleigh, NC 27695 USA
[3] Univ North Carolina Chapel Hill, Joint Dept Biomed Engn, Chapel Hill, NC 27599 USA
关键词
body-conforming ultrasound-compatible electrode; functional electrical stimulation (FES); silver nanowire (AgNW) electrode; ultrasound (US); wearable ultrasound; SPINAL-CORD-INJURY; MUSCLE; ULTRASONOGRAPHY;
D O I
10.3390/biomedicines12081741
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Functional electrical stimulation (FES) is a vital method in neurorehabilitation used to reanimate paralyzed muscles, enhance the size and strength of atrophied muscles, and reduce spasticity. FES often leads to increased muscle fatigue, necessitating careful monitoring of the patient's response. Ultrasound (US) imaging has been utilized to provide valuable insights into FES-induced fatigue by assessing changes in muscle thickness, stiffness, and strain. Current commercial FES electrodes lack sufficient US transparency, hindering the observation of muscle activity beneath the skin where the electrodes are placed. US-compatible electrodes are essential for accurate imaging and optimal FES performance, especially given the spatial constraints of conventional US probes and the need to monitor muscle areas directly beneath the electrodes. This study introduces specially designed body-conforming US-compatible FES (US-FES) electrodes constructed with a silver nanowire/polydimethylsiloxane (AgNW/PDMS) composite. We compared the performance of our body-conforming US-FES electrode with a commercial hydrogel electrode. The findings revealed that our US-FES electrode exhibited comparable conductivity and performance to the commercial one. Furthermore, US compatibility was investigated through phantom and in vivo tests, showing significant compatibility even during FES, unlike the commercial electrode. The results indicated that US-FES electrodes hold significant promise for the real-time monitoring of muscle activity during FES in clinical rehabilitative applications.
引用
收藏
页数:19
相关论文
共 31 条
  • [1] Consensus Statement on the Classification of Tremors. From the Task Force on Tremor of the International Parkinson and Movement Disorder Society
    Bhatia, Kailash P.
    Bain, Peter
    Bajaj, Nin
    Elble, Rodger J.
    Hallett, Mark
    Louis, Elan D.
    Raethjen, Jan
    Stamelou, Maria
    Testa, Claudia M.
    Deuschl, Guenther
    [J]. MOVEMENT DISORDERS, 2018, 33 (01) : 75 - 87
  • [2] Flexible Ultrasound Transducer With Embedded Optical Shape Sensing Fiber for Biomedical Imaging Applications
    Chen, Weicen
    Liu, Jiamei
    Lei, Shuang
    Yang, Zidong
    Zhang, Qi
    Li, Yongchuan
    Huang, Jiqing
    Dong, Yuming
    Zheng, Hairong
    Wu, Dawei
    Ma, Teng
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (10) : 2841 - 2851
  • [3] The Need for Standardized Assessment of Muscle Quality in Skeletal Muscle Function Deficit and Other Aging-Related Muscle Dysfunctions: A Symposium Report
    Correa-de-Araujo, Rosaly
    Harris-Love, Michael O.
    Miljkovic, Iva
    Fragala, Maren S.
    Anthony, Brian W.
    Manini, Todd M.
    [J]. FRONTIERS IN PHYSIOLOGY, 2017, 8
  • [4] Multi-Sensing Techniques with Ultrasound for Musculoskeletal Assessment: A Review
    de Oliveira, Jonathan
    de Souza, Mauren Abreu
    Assef, Amauri Amorin
    Maia, Joaquim Miguel
    [J]. SENSORS, 2022, 22 (23)
  • [5] Real-Time Visual Biofeedback via Wearable Ultrasound Imaging Can Enhance the Muscle Contraction Training Outcome of Young Adults
    Huang, Zi-Hao
    Ma, Christina Z-H
    Wang, Li-Ke
    Wang, Xiao-Yun
    Fu, Siu-Ngor
    Zheng, Yong-Ping
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2022, 36 (04) : 941 - 947
  • [6] The Muscle Thickness Assessment Using Ultrasonography is a Useful Alternative to Skeletal Muscle Mass by Bioelectrical Impedance Analysis
    Isaka, Masaaki
    Sugimoto, Ken
    Akasaka, Hiroshi
    Yasunobe, Yukiko
    Takahashi, Toshimasa
    Xie, Keyu
    Onishi, Yuri
    Yoshida, Shino
    Minami, Tomohiro
    Yamamoto, Koichi
    Kamide, Kei
    Rakugi, Hiromi
    [J]. CLINICAL INTERVENTIONS IN AGING, 2022, 17 : 1851 - 1861
  • [7] Traumatic Spinal Cord Injury in the United States, 1993-2012
    Jain, Nitin B.
    Ayers, Gregory D.
    Peterson, Emily N.
    Harris, Mitchel B.
    Morse, Leslie
    O'Connor, Kevin C.
    Garshick, Eric
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2015, 313 (22): : 2236 - 2243
  • [8] Flexible 1-3 Composite Ultrasound Transducers With Silver-Nanowire-Based Stretchable Electrodes
    Kim, Taeyang
    Cui, Zheng
    Chang, Wei-Yi
    Kim, Howuk
    Zhu, Yong
    Jiang, Xiaoning
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (08) : 6955 - 6962
  • [9] A MODEL FOR ESTIMATING SPINAL-CORD INJURY PREVALENCE IN THE UNITED-STATES
    LASFARGUES, JE
    CUSTIS, D
    MORRONE, F
    CARSWELL, J
    NGUYEN, T
    [J]. PARAPLEGIA, 1995, 33 (02): : 62 - 68
  • [10] A Method for Suppressing Electrical Stimulation Artifacts from Electromyography
    Li, Yurong
    Chen, Jun
    Yang, Yuan
    [J]. INTERNATIONAL JOURNAL OF NEURAL SYSTEMS, 2019, 29 (06)