Impact of AI for Digital Breast Tomosynthesis on Breast Cancer Detection and Interpretation Time

被引:4
|
作者
Park, Eun Kyung [1 ]
Kwak, SooYoung [1 ]
Lee, Weonsuk [1 ]
Choi, Joon Suk [1 ]
Kooi, Thijs [1 ]
Kim, Eun-Kyung [2 ]
机构
[1] Lunit, 374 Gangnam Daero, Seoul 06241, South Korea
[2] Yonsei Univ, Yongin Severance Hosp, Dept Radiol, Coll Med, Yongin, South Korea
关键词
COMPUTER-AIDED DETECTION; ARTIFICIAL-INTELLIGENCE; SCREENING MAMMOGRAPHY; OUTCOMES; PERFORMANCE; ACCURACY; EUROPE;
D O I
10.1148/ryai.230318
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Purpose: To develop an artificial intelligence (AI) model for the diagnosis of breast cancer on digital breast tomosynthesis (DBT) images and to investigate whether it could improve diagnostic accuracy and reduce radiologist reading time. Materials and Methods: A deep learning AI algorithm was developed and validated for DBT with retrospectively collected examinations (January 2010 to December 2021) from 14 institutions in the United States and South Korea. A multicenter reader study was performed to compare the performance of 15 radiologists (seven breast specialists, eight general radiologists) in interpreting DBT examinations in 258 women (mean age, 56 years +/- 13.41 [SD]), including 65 cancer cases, with and without the use of AI. Area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and reading time were evaluated. Results: The AUC for stand-alone AI performance was 0.93 (95% CI: 0.92, 0.94). With AI, radiologists' AUC improved from 0.90 (95% CI: 0.86, 0.93) to 0.92 (95% CI: 0.88, 0.96) (P = .003) in the reader study. AI showed higher specificity (89.64% [95% CI: 85.34%, 93.94%]) than radiologists (77.34% [95% CI: 75.82%, 78.87%]) (P < .001). When reading with AI, radiologists' sensitivity increased from 85.44% (95% CI: 83.22%, 87.65%) to 87.69% (95% CI: 85.63%, 89.75%) (P = .04), with no evidence of a difference in specificity. Reading time decreased from 54.41 seconds (95% CI: 52.56, 56.27) without AI to 48.52 seconds (95% CI: 46.79, 50.25) with AI (P < .001). Interreader agreement measured by Fleiss kappa increased from 0.59 to 0.62. Conclusion: The AI model showed better diagnostic accuracy than radiologists in breast cancer detection, as well as reduced reading times. The concurrent use of AI in DBT interpretation could improve both accuracy and efficiency.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] The Adjunctive Digital Breast Tomosynthesis in Diagnosis of Breast Cancer
    Yang, Tsung-Lung
    Liang, Huei-Lung
    Chou, Chen-Pin
    Huang, Jer-Shyung
    Pan, Huay-Ben
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [22] The added benefit of digital breast tomosynthesis in second breast cancer detection among treated breast cancer patients
    Osman, Noha Mohamed
    Ghany, Enas Abdel
    Chalabi, Nivine
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2018, 49 (04): : 1182 - 1186
  • [23] Artificial intelligence for breast cancer detection in mammography and digital breast tomosynthesis: State of the art
    Sechopoulos, Ioannis
    Teuwen, Jonas
    Mann, Ritse
    SEMINARS IN CANCER BIOLOGY, 2021, 72 : 214 - 225
  • [24] Applying deep learning in digital breast tomosynthesis for automatic breast cancer detection: A review
    Bai, Jun
    Posner, Russell
    Wang, Tianyu
    Yang, Clifford
    Nabavi, Sheida
    MEDICAL IMAGE ANALYSIS, 2021, 71
  • [25] Digital Breast Tomosynthesis Screening Improves Early Breast Cancer Detection and Survival in Taiwan
    Wu, Pei-Shan
    Hong, Yu-Ting
    Shen, Chiao-Hsuan
    Lee, Chao-Hsien
    Chou, Chen-Pin
    JOURNAL OF BREAST IMAGING, 2024, 6 (06) : 601 - 609
  • [26] Effect of radiologists’ experience on breast cancer detection and localization using digital breast tomosynthesis
    Maram M. Alakhras
    Patrick C. Brennan
    Mary Rickard
    Roger Bourne
    Claudia Mello-Thoms
    European Radiology, 2015, 25 : 402 - 409
  • [27] Budget impact analysis of introducing digital breast tomosynthesis in breast cancer screening in Italy
    Djuric, Olivera
    Deandrea, Silvia
    Mantellini, Paola
    Sardanelli, Francesco
    Venturelli, Francesco
    Montemezzi, Stefania
    Vecchio, Riccardo
    Bucchi, Lauro
    Senore, Carlo
    Giordano, Livia
    Paci, Eugenio
    Bonifacino, Adriana
    Calabrese, Massimo
    Caumo, Francesca
    Degrassi, Flori
    de' Bianchi, Priscilla Sassoli
    Battisti, Francesca
    Zappa, Marco
    Pattacini, Pierpaolo
    Campari, Cinzia
    Nitrosi, Andrea
    Di Leo, Giovanni
    Frigerio, Alfonso
    Magni, Veronica
    Fornasa, Francesca
    Romanucci, Giovanna
    Falini, Patrizia
    Auzzi, Noemi
    Armaroli, Paola
    Giorgi Rossi, Paolo
    RADIOLOGIA MEDICA, 2024, 129 (09): : 1288 - 1302
  • [28] Three-dimensional digital breast tomosynthesis in the early diagnosis and detection of breast cancer
    Varjonen, Mari
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2006, 4046 : 152 - 159
  • [29] The impact of breast structure on lesion detection in breast tomosynthesis
    Kiarashi, Nooshin
    Nolte, Loren W.
    Lo, Joseph Y.
    Segars, William P.
    Ghate, Sujata V.
    Samei, Ehsan
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [30] Effect of radiologists' experience on breast cancer detection and localization using digital breast tomosynthesis
    Alakhras, Maram M.
    Brennan, Patrick C.
    Rickard, Mary
    Bourne, Roger
    Mello-Thoms, Claudia
    EUROPEAN RADIOLOGY, 2015, 25 (02) : 402 - 409