Material properties and finite element analysis of adhesive cements used for zirconia crowns on dental implants

被引:0
作者
Satpathy, Megha [1 ]
Pham, Hai [1 ]
Shah, Shreya [1 ]
机构
[1] Glidewell Labs, Res & Dev, Irvine, CA 92612 USA
关键词
Dental cements; dental implants; finite element analysis (FEA); computer-aided design (CAD); failure analysis; SHEAR-BOND STRENGTH; SELF-ADHESIVE; RESIN CEMENTS; ONE-PIECE; STRESS-CONCENTRATION; RESTORATIONS; THICKNESS;
D O I
10.1080/10255842.2024.2404152
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This study aimed to evaluate the material properties of four dental cements, analyze the stress distribution on the cement layer under various loading conditions, and perform failure analysis on the fractured specimens retrieved from mechanical tests. Microhardness indentation testing is used to measure material hardness microscopically with a diamond indenter. The hardness and elastic moduli of three self-adhesive resin cements (SARC), namely, DEN CEM (DENTEX, Changchun, China), Denali (Glidewell Laboratories, CA, USA), and Glidewell Experimental SARC (GES-Glidewell Laboratories, CA, USA), and a resin-modified glass ionomer (RMGI-Glidewell Laboratories, CA, USA) cement, were measured using microhardness indentation. These values were used in the subsequent Finite Element Analysis (FEA) to analyze the von Mises stress distribution on the cement layer of a 3D implant model constructed in SOLIDWORKS under different mechanical forces. Failure analysis was performed on the fractured specimens retrieved from prior mechanical tests. All the cements, except Denali, had elastic moduli comparable to dentin (8-15 GPa). RMGI with primer and GES cements exhibited the lowest von Mises stresses under tensile and compressive loads. Stress distribution under tensile and compressive loads correlated well with experimental tests, unlike oblique loads. Failure analysis revealed that damages on the abutment and screw vary significantly with loading direction. GES and RMGI cement with primer (Glidewell Laboratories, CA, USA) may be suitable options for cement-retained zirconia crowns on titanium abutments. Adding fillets to the screw thread crests can potentially reduce the extent of the damage under load.
引用
收藏
页数:21
相关论文
共 91 条
  • [1] Convergence of Finite Element Model for Crushing of a Conical Thin-walled Tube
    Ahmad, M.
    Ismail, K. A.
    Mat, F.
    [J]. MALAYSIAN TECHNICAL UNIVERSITIES CONFERENCE ON ENGINEERING & TECHNOLOGY 2012 (MUCET 2012), 2013, 53 : 586 - 593
  • [2] [Anonymous], 2015, 11405 ISOTS
  • [3] [Anonymous], 2016, DentistryImplantsDynamic Loading Test for Endosseous Dental Implants
  • [4] ASM, 2024, Titanium Ti-6Al-4V
  • [5] Influence of Resin Cement Thickness and Elastic Modulus on the Stress Distribution of Zirconium Dioxide Inlay-Bridge: 3D Finite Element Analysis
    Assaf, Joseph
    Hardan, Louis
    Kassis, Cynthia
    Bourgi, Rim
    Devoto, Walter
    Amm, Elie
    Moussa, Carol
    Sawicki, Jacek
    Lukomska-Szymanska, Monika
    [J]. POLYMERS, 2021, 13 (22)
  • [6] The Mechanical Behaviors of Various Dental Implant Materials under Fatigue
    Bayata, Fatma
    Yildiz, Cengiz
    [J]. ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2018, 2018
  • [7] One-piece versus two-piece ceramic dental implants
    Bollen, Curd
    Hakobayan, Gagik
    Jorgens, Martin
    [J]. BRITISH DENTAL JOURNAL, 2024, 236 (05) : 383 - 387
  • [8] Boyer R.R., 1994, Materials Properties Handbook: Titanium Alloys
  • [9] Brandes EA., 2004, Smithells metals reference book, P21, DOI [10.1016/B978-075067509-3/50024-5, DOI 10.1016/B978-075067509-3/50024-5]
  • [10] Effectiveness of Self-Adhesive Resin Luting Cement in CAD-CAM Blocks-A Systematic Review and Meta-Analysis
    Calheiros-Lobo, Maria Joao
    Vieira, Tatiana
    Carbas, Ricardo
    da Silva, Lucas F. M.
    Pinho, Teresa
    [J]. MATERIALS, 2023, 16 (08)