Development of Quantitative Norms for Normal Lung Uptake Based on Three-Dimensional Gallium-67 Single Photon Emission Computed Tomography/Computed Tomography

被引:0
|
作者
Chuang, Tzyy-Ling [1 ,2 ]
Li, Wei-Lin [3 ]
Hs, Yu-Ching [1 ]
Chen, Jyh-Cheng [3 ,4 ,5 ]
Wang, Yuh-Feng [3 ,6 ,7 ]
机构
[1] Dalin Tzu Chi Hosp, Buddhist Tzu Chi Med Fdn, Dept Nucl Med, Chiayi, Taiwan
[2] Tzu Chi Univ, Sch Med, Hualien, Taiwan
[3] Natl Yang Ming Chiao Tung Univ, Sch Biomed Sci & Engn, Dept Biomed Imaging & Radiol Sci, Taipei, Taiwan
[4] China Med Univ, Dept Med Imaging & Radiol Sci, Taichung, Taiwan
[5] Xuzhou Med Univ, Sch Med Imaging, Xuzhou, Jiangsu, Peoples R China
[6] Taipei Vet Gen Hosp, Dept Nucl Med, Taipei, Taiwan
[7] Yuanpei Univ Med Technol, Dept Med Imaging & Radiol Technol, Hsinchu, Taiwan
关键词
Ga-67; Alveolitis; Interstitial lung disease; SPECT/CT; DISEASE-ACTIVITY; PULMONARY; SARCOIDOSIS; SCINTIGRAPHY; ALVEOLITIS; INDEX; SCANS;
D O I
10.1007/s40846-024-00905-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeGallium-67 (Ga-67) lung scans assess alveolitis and interstitial lung disease, with Ga-67 accumulation correlating with inflammation intensity as seen in lung biopsy sections. Both semi-quantitative and quantitative methods have been used, with the latter providing an inflammatory activity index linked to lung lavage and histopathological scores. However, differing reference points result in varying outcomes. This study aimed to establish standard Ga-67 index parameters using semi-quantitative analysis and a linear regression model based on planar and SPECT/CT images.MethodsTwenty subjects without lung disease received a 5-6 mCi Ga-67 injection via the ankle. Both planar and SPECT/CT images were analyzed, with semi-quantitative values assessed using GraphPad Prism 9.5.1.ResultsCompared to planar images, SPECT/CT acquisitions for the lung-to-arm uptake ratio proved the most reliable indicator for assessing lung inflammation. Increased lung Ga-67 uptake was defined as greater than 2 standard deviations from the average Ga-67 uptake for healthy subjects. The normal range was 0.065 +/- 0.049 for the right side and 0.076 +/- 0.070 for the left side.ConclusionLung-to-arm ratios in SPECT/CT images are more accurate than those in planar images. This method should be adopted as a standard clinical practice, providing more reliable diagnostic information and improving patient management. Future studies should compare patients without lung disease to those with lung disease to determine the diagnostic benefit of these norms.
引用
收藏
页码:696 / 703
页数:8
相关论文
共 50 条
  • [41] The Usefulness of Maximum Standardized Uptake Value at the Delayed Phase of Tc-99m sestamibi single-photon emission computed tomography/computed tomography for Identification of Parathyroid Adenoma and Hyperplasia
    Suh, Hoon Young
    Na, Hee Young
    Park, So Yeon
    Choi, June Young
    So, Young
    Lee, Won Woo
    MEDICINE, 2020, 99 (28) : E21176
  • [42] Comparison between lung perfusion scan and single-photon emission computed tomography/computed tomography for predicting postoperative lung function after pulmonary resection in patients with borderline lung function
    Na, Kwon Joong
    Park, Samina
    Lee, Hyun Joo
    Park, In Kyu
    Kang, Chang Hyun
    Kim, Young Tae
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (06) : 1228 - 1235
  • [43] Asynchronous changes of normal lung lobes during respiration based on quantitative computed tomography (CT)
    Wu, Feihong
    Lin, Congping
    Chen, Leqing
    Huang, Jia
    Fan, Wenliang
    Nie, Zhuang
    Zhang, Yiwei
    Li, Wanting
    Wang, Jiazheng
    Yang, Fan
    Zheng, Chuansheng
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (03) : 2018 - 2034
  • [44] Pilot study for comparative assessment of dual-energy computed tomography and single-photon emission computed tomography V/Q scanning for lung perfusion evaluation in infants
    Ramirez-Suarez, Karen, I
    Barrera, Christian A.
    Otero, Hansel J.
    Biko, David M.
    States, Lisa J.
    Servaes, Sabah
    Zhu, Xiaowei
    Davis, James C.
    Piccione, Joseph
    Rapp, Jordan B.
    PEDIATRIC PULMONOLOGY, 2022, 57 (03) : 702 - 710
  • [45] Correlation between the maximum standard uptake value and mean Hounsfield unit on single-photon emission computed tomography-computed tomography to discriminate benign and metastatic lesions among patients with breast cancer
    Saminathan, S. Thadchaiani
    Ahmed, Wan Aireene Wan
    Nawi, Norazlina Mat
    Tagiling, Nashrulhaq
    Aziz, Ilyana
    Udin, Yusri
    Rohani, Mohd Fazrin Mohd
    Zainon, Wan Mohd Nazlee Wan
    Razab, Mohammad Khairul Azhar Abdul
    ASIAN SPINE JOURNAL, 2024, 18 (03) : 398 - 406
  • [46] Impacts of different reconstruction methods on the image quality of cadmium-zinc-telluride-based single photon emission computed tomography/computed tomography pulmonary perfusion imaging
    Wu, Weiming
    Zhang, Ruyi
    Zhou, Yaqian
    Wang, Shen
    Shen, Yiming
    Li, Ning
    Tan, Jian
    Zheng, Wei
    Jia, Qiang
    Meng, Zhaowei
    NUCLEAR MEDICINE COMMUNICATIONS, 2023, 44 (08) : 673 - 681
  • [47] Evaluation of iodine-123-labeled metaiodobenzylguanidine single- photon emission computed tomography/computed tomography based on the International Society of Pediatric Oncology Europe Neuroblastoma score in children with neuroblastoma
    Zhou, Ziang
    Wang, Guanyun
    Qian, Luodan
    Liu, Jun
    Yang, Xu
    Zhang, Shuxin
    Zhang, Mingyu
    Kan, Ying
    Wang, Wei
    Yang, Jigang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (06) : 3841 - 3851
  • [48] Deep-learning-based attenuation map generation in kidney single photon emission computed tomography
    Kwon, Kyounghyoun
    Oh, Dongkyu
    Kim, Ji Hye
    Yoo, Jihyung
    Lee, Won Woo
    EJNMMI PHYSICS, 2024, 11 (01):
  • [49] Usefulness of F-18-Fluorodeoxyglucose-position emission tomography with computed tomography and gallium-67 scintigraphy for detection of Kaposi sarcoma lesions in a 40-year-old Japanese man with AIDS
    Suzuki, Jun
    Sasahara, Teppei
    Toshima, Masaki
    Norizuki, Masataro
    Onishi, Tsubasa
    Okabe, Taro
    Minami, Kensuke
    Morisawa, Yuji
    IDCASES, 2015, 2 (03): : 68 - 69
  • [50] The application of extraocular muscle maximum standardized uptake value of 99mTc-diethylenetriamine pentaacetic acid orbital single photon emission computed tomography/computed tomography in the assessment of Graves' orbitopathy
    Lu, Chao
    Yu, Yang
    Wang, Shen
    Yin, Xue
    Zheng, Hongyuan
    Li, Xiangxiang
    Jia, Qiang
    Zheng, Wei
    NUCLEAR MEDICINE COMMUNICATIONS, 2025, 46 (02) : 120 - 127