Development of Quantitative Norms for Normal Lung Uptake Based on Three-Dimensional Gallium-67 Single Photon Emission Computed Tomography/Computed Tomography

被引:0
|
作者
Chuang, Tzyy-Ling [1 ,2 ]
Li, Wei-Lin [3 ]
Hs, Yu-Ching [1 ]
Chen, Jyh-Cheng [3 ,4 ,5 ]
Wang, Yuh-Feng [3 ,6 ,7 ]
机构
[1] Dalin Tzu Chi Hosp, Buddhist Tzu Chi Med Fdn, Dept Nucl Med, Chiayi, Taiwan
[2] Tzu Chi Univ, Sch Med, Hualien, Taiwan
[3] Natl Yang Ming Chiao Tung Univ, Sch Biomed Sci & Engn, Dept Biomed Imaging & Radiol Sci, Taipei, Taiwan
[4] China Med Univ, Dept Med Imaging & Radiol Sci, Taichung, Taiwan
[5] Xuzhou Med Univ, Sch Med Imaging, Xuzhou, Jiangsu, Peoples R China
[6] Taipei Vet Gen Hosp, Dept Nucl Med, Taipei, Taiwan
[7] Yuanpei Univ Med Technol, Dept Med Imaging & Radiol Technol, Hsinchu, Taiwan
关键词
Ga-67; Alveolitis; Interstitial lung disease; SPECT/CT; DISEASE-ACTIVITY; PULMONARY; SARCOIDOSIS; SCINTIGRAPHY; ALVEOLITIS; INDEX; SCANS;
D O I
10.1007/s40846-024-00905-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeGallium-67 (Ga-67) lung scans assess alveolitis and interstitial lung disease, with Ga-67 accumulation correlating with inflammation intensity as seen in lung biopsy sections. Both semi-quantitative and quantitative methods have been used, with the latter providing an inflammatory activity index linked to lung lavage and histopathological scores. However, differing reference points result in varying outcomes. This study aimed to establish standard Ga-67 index parameters using semi-quantitative analysis and a linear regression model based on planar and SPECT/CT images.MethodsTwenty subjects without lung disease received a 5-6 mCi Ga-67 injection via the ankle. Both planar and SPECT/CT images were analyzed, with semi-quantitative values assessed using GraphPad Prism 9.5.1.ResultsCompared to planar images, SPECT/CT acquisitions for the lung-to-arm uptake ratio proved the most reliable indicator for assessing lung inflammation. Increased lung Ga-67 uptake was defined as greater than 2 standard deviations from the average Ga-67 uptake for healthy subjects. The normal range was 0.065 +/- 0.049 for the right side and 0.076 +/- 0.070 for the left side.ConclusionLung-to-arm ratios in SPECT/CT images are more accurate than those in planar images. This method should be adopted as a standard clinical practice, providing more reliable diagnostic information and improving patient management. Future studies should compare patients without lung disease to those with lung disease to determine the diagnostic benefit of these norms.
引用
收藏
页码:696 / 703
页数:8
相关论文
共 50 条
  • [31] Assessment of Myocardial Infarct Size by Three-Dimensional and Two-Dimensional Speckle Tracking Echocardiography: A Comparative Study to Single Photon Emission Computed Tomography
    Wang, Qiushuang
    Huang, Dangsheng
    Zhang, Liwei
    Shen, Dong
    Ouyang, Qiaohong
    Duan, Zhongxiang
    An, Xiuzhi
    Zhang, Meiqing
    Zhang, Chunhong
    Yang, Feifei
    Zhi, Guang
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (10): : 1539 - 1546
  • [32] Single-photon emission computed tomography/computed tomography for evaluation of salivary gland dysfunction: preliminary study on diagnostic ability of maximum standardized uptake value
    Kazunori Ninomiya
    Shuji Toya
    Ichiro Ogura
    Oral Radiology, 2020, 36 : 163 - 167
  • [33] Physiological Uptake of Radioactive Iodine Around an Artificial Eyeball Observed with Single-Photon Emission Computed Tomography/Computed Tomography After Radioactive Iodine Treatment
    Lee, Ji Young
    Song, Hee-Sung
    Kang, Myoungsihn
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 54 (04) : 204 - 206
  • [34] Maximum standardized uptake value from quantitative bone single-photon emission computed tomography/computed tomography in differentiating metastatic and degenerative joint disease of the spine in prostate cancer patients
    Rohani, Mohd Fazrin Mohd
    Nawi, Norazlina Mat
    Shamim, Syed Ejaz
    Sohaimi, Wan Fatihah Wan
    Zainon, Wan Mohd Nazlee Wan
    Musarudin, Marianie
    Said, Mohamad Aminudin
    Hashim, Hazlin
    ANNALS OF NUCLEAR MEDICINE, 2020, 34 (01) : 39 - 48
  • [35] Effect of phantom-making error in the calculation of quantitative values of single-photon emission computed tomography/computed tomography using system planar sensitivity
    Nojima, Yuta
    Yamazaki, Yoshihiro
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2025, 11 (01):
  • [36] Coronal Deformity is Associated With Uptake on Single Photon Emission Computed Tomography in Patients With Low Back Pain
    Dharia, Anand A.
    Guillotte, Andrew R.
    De Stefano, Frank A.
    Birney, Mia J.
    Rouse, Adam G.
    Ohiorhenuan, Ifije E.
    GLOBAL SPINE JOURNAL, 2024,
  • [37] Physiological Uptake of Radioactive Iodine Around an Artificial Eyeball Observed with Single-Photon Emission Computed Tomography/Computed Tomography After Radioactive Iodine Treatment
    Ji Young Lee
    Hee-Sung Song
    Myoungsihn Kang
    Nuclear Medicine and Molecular Imaging, 2020, 54 : 204 - 206
  • [38] The conclusions drawn from ventilation/perfusion single-photon emission computed tomography compared with lung perfusion single-photon emission computed tomography and chest radiography in patients with suspected pulmonary thromboembolism
    Abubakar, Sofiullah
    Jacobs, Donovan
    Kotze, Tessa
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (10) : 908 - 914
  • [39] Quantitative Iodine-123 single-photon emission computed tomography/computed tomography for Iodine-131 therapy of an autonomously functioning thyroid nodule
    Won Woo Lee
    Yoo Sung Song
    Young So
    European Journal of Hybrid Imaging, 7
  • [40] Quantitative Scintigraphy Imaging of Lingual Raynaud's Phenomenon Using 3-Dimensional-Ring Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography/Computed Tomography
    Yoo, Ik Dong
    Jo, In Young
    Jeong, Geum Cheol
    Won, Yong Kyun
    Jeong, Du Shin
    Lee, Sang Mi
    TOMOGRAPHY, 2022, 8 (04) : 2042 - 2048