Development of Quantitative Norms for Normal Lung Uptake Based on Three-Dimensional Gallium-67 Single Photon Emission Computed Tomography/Computed Tomography

被引:0
|
作者
Chuang, Tzyy-Ling [1 ,2 ]
Li, Wei-Lin [3 ]
Hs, Yu-Ching [1 ]
Chen, Jyh-Cheng [3 ,4 ,5 ]
Wang, Yuh-Feng [3 ,6 ,7 ]
机构
[1] Dalin Tzu Chi Hosp, Buddhist Tzu Chi Med Fdn, Dept Nucl Med, Chiayi, Taiwan
[2] Tzu Chi Univ, Sch Med, Hualien, Taiwan
[3] Natl Yang Ming Chiao Tung Univ, Sch Biomed Sci & Engn, Dept Biomed Imaging & Radiol Sci, Taipei, Taiwan
[4] China Med Univ, Dept Med Imaging & Radiol Sci, Taichung, Taiwan
[5] Xuzhou Med Univ, Sch Med Imaging, Xuzhou, Jiangsu, Peoples R China
[6] Taipei Vet Gen Hosp, Dept Nucl Med, Taipei, Taiwan
[7] Yuanpei Univ Med Technol, Dept Med Imaging & Radiol Technol, Hsinchu, Taiwan
关键词
Ga-67; Alveolitis; Interstitial lung disease; SPECT/CT; DISEASE-ACTIVITY; PULMONARY; SARCOIDOSIS; SCINTIGRAPHY; ALVEOLITIS; INDEX; SCANS;
D O I
10.1007/s40846-024-00905-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeGallium-67 (Ga-67) lung scans assess alveolitis and interstitial lung disease, with Ga-67 accumulation correlating with inflammation intensity as seen in lung biopsy sections. Both semi-quantitative and quantitative methods have been used, with the latter providing an inflammatory activity index linked to lung lavage and histopathological scores. However, differing reference points result in varying outcomes. This study aimed to establish standard Ga-67 index parameters using semi-quantitative analysis and a linear regression model based on planar and SPECT/CT images.MethodsTwenty subjects without lung disease received a 5-6 mCi Ga-67 injection via the ankle. Both planar and SPECT/CT images were analyzed, with semi-quantitative values assessed using GraphPad Prism 9.5.1.ResultsCompared to planar images, SPECT/CT acquisitions for the lung-to-arm uptake ratio proved the most reliable indicator for assessing lung inflammation. Increased lung Ga-67 uptake was defined as greater than 2 standard deviations from the average Ga-67 uptake for healthy subjects. The normal range was 0.065 +/- 0.049 for the right side and 0.076 +/- 0.070 for the left side.ConclusionLung-to-arm ratios in SPECT/CT images are more accurate than those in planar images. This method should be adopted as a standard clinical practice, providing more reliable diagnostic information and improving patient management. Future studies should compare patients without lung disease to those with lung disease to determine the diagnostic benefit of these norms.
引用
收藏
页码:696 / 703
页数:8
相关论文
共 50 条
  • [21] Single-photon emission computed tomography/computed tomography iodine-131 uptake of bronchiectasis masquerading as metastatic thryroid disease
    Mack, Takman
    Miller, Jessica
    Silverman, Eugene
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2015, 30 (03): : 292 - 293
  • [22] Discrepancy between Dual-Energy Computed Tomography Lung Perfusion Blood Volume and Lung Perfusion Single-Photon Emission Computed Tomography/Computed Tomography Images in Pulmonary Embolism
    Koike, Hirofumi
    Sueyoshi, Eijun
    Nagayama, Hiroki
    Ashizawa, Kazuto
    Sakamoto, Ichiro
    Uetani, Masataka
    Kudo, Takashi
    Ikeda, Satoshi
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189 (12) : E71 - E72
  • [23] Single-photon emission computed tomography/computed tomography for evaluation of salivary gland dysfunction: preliminary study on diagnostic ability of maximum standardized uptake value
    Ninomiya, Kazunori
    Toya, Shuji
    Ogura, Ichiro
    ORAL RADIOLOGY, 2020, 36 (02) : 163 - 167
  • [24] Quantitative Bone Single Photon Emission Computed Tomography/Computed Tomography for Evaluating Response to Bisphosphonate Treatment in Patients with Paget's Disease of Bone
    Kitajima, Kazuhiro
    Futani, Hiroyuki
    Tsuchitani, Tatsuya
    Takahashi, Yoshiyuki
    Yamakado, Koichiro
    CASE REPORTS IN ONCOLOGY, 2020, 13 (02): : 829 - 834
  • [25] Bone and Gallium Single-Photon Emission Computed Tomography-Computed Tomography is Equivalent to Magnetic Resonance Imaging in the Diagnosis of Infectious Spondylodiscitis: A Retrospective Study
    Tamm, Alexander S.
    Abele, Jonathan T.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2017, 68 (01): : 41 - 46
  • [26] 131I Uptake in Bronchiectasis Detected by Single Photon Emission Computed Tomography/Computed Tomography during Follow-up of Thyroid Cancer
    Calabria, Ferdinando
    Lanzillotta, Antonio
    Leporace, Mario
    Guadagnino, Giuliana
    Schillaci, Orazio
    Bagnato, Antonio
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 34 (03): : 235 - 236
  • [27] Minimum Standardized Uptake Value from Quantitative Bone Single-Photon Emission Computed Tomography/Computed Tomography for Evaluation of Femoral Head Viability in Patients with Femoral Neck Fracture
    Ryoo, Hyun Gee
    Lee, Won Woo
    Kim, Ji Young
    Kong, Eunjung
    Choi, Woo Hee
    Yoon, Joon-Kee
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 53 (04) : 287 - 295
  • [28] Image findings of a false positive radioactive iodine-131 uptake mimicking metastasis in pulmonary aspergillosis identified on single photon emission computed tomography-computed tomography
    Karuppusamy, Kamaleshwaran Koramadai
    Antony, Joppy
    Radhakrishnan, E. R.
    Shinto, Ajit Sugunan
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2015, 11 (03) : 656
  • [29] Standardization of quantitative single photon emission computed tomography in control individuals and in patients with condylar hyperplasia
    AlSharif, Abedallatif A.
    Tarawneh, Emad S.
    AlKawaleet, Yazan I.
    Abukaraky, Ashraf E.
    AlAhmad, Hazem T.
    Malkawi, Ziad A.
    Juweid, Malik E.
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (12) : 1268 - 1276
  • [30] Diagnostic value of ventilation/perfusion single-photon emission computed tomography/computed tomography for bronchiolitis obliterans syndrome in patients after lung transplantation
    Nakashima, Masahiro
    Shinya, Takayoshi
    Oto, Takahiro
    Okawa, Tomoyo
    Takeda, Yoshihiro
    NUCLEAR MEDICINE COMMUNICATIONS, 2019, 40 (07) : 703 - 710