Development of Quantitative Norms for Normal Lung Uptake Based on Three-Dimensional Gallium-67 Single Photon Emission Computed Tomography/Computed Tomography

被引:0
|
作者
Chuang, Tzyy-Ling [1 ,2 ]
Li, Wei-Lin [3 ]
Hs, Yu-Ching [1 ]
Chen, Jyh-Cheng [3 ,4 ,5 ]
Wang, Yuh-Feng [3 ,6 ,7 ]
机构
[1] Dalin Tzu Chi Hosp, Buddhist Tzu Chi Med Fdn, Dept Nucl Med, Chiayi, Taiwan
[2] Tzu Chi Univ, Sch Med, Hualien, Taiwan
[3] Natl Yang Ming Chiao Tung Univ, Sch Biomed Sci & Engn, Dept Biomed Imaging & Radiol Sci, Taipei, Taiwan
[4] China Med Univ, Dept Med Imaging & Radiol Sci, Taichung, Taiwan
[5] Xuzhou Med Univ, Sch Med Imaging, Xuzhou, Jiangsu, Peoples R China
[6] Taipei Vet Gen Hosp, Dept Nucl Med, Taipei, Taiwan
[7] Yuanpei Univ Med Technol, Dept Med Imaging & Radiol Technol, Hsinchu, Taiwan
关键词
Ga-67; Alveolitis; Interstitial lung disease; SPECT/CT; DISEASE-ACTIVITY; PULMONARY; SARCOIDOSIS; SCINTIGRAPHY; ALVEOLITIS; INDEX; SCANS;
D O I
10.1007/s40846-024-00905-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeGallium-67 (Ga-67) lung scans assess alveolitis and interstitial lung disease, with Ga-67 accumulation correlating with inflammation intensity as seen in lung biopsy sections. Both semi-quantitative and quantitative methods have been used, with the latter providing an inflammatory activity index linked to lung lavage and histopathological scores. However, differing reference points result in varying outcomes. This study aimed to establish standard Ga-67 index parameters using semi-quantitative analysis and a linear regression model based on planar and SPECT/CT images.MethodsTwenty subjects without lung disease received a 5-6 mCi Ga-67 injection via the ankle. Both planar and SPECT/CT images were analyzed, with semi-quantitative values assessed using GraphPad Prism 9.5.1.ResultsCompared to planar images, SPECT/CT acquisitions for the lung-to-arm uptake ratio proved the most reliable indicator for assessing lung inflammation. Increased lung Ga-67 uptake was defined as greater than 2 standard deviations from the average Ga-67 uptake for healthy subjects. The normal range was 0.065 +/- 0.049 for the right side and 0.076 +/- 0.070 for the left side.ConclusionLung-to-arm ratios in SPECT/CT images are more accurate than those in planar images. This method should be adopted as a standard clinical practice, providing more reliable diagnostic information and improving patient management. Future studies should compare patients without lung disease to those with lung disease to determine the diagnostic benefit of these norms.
引用
收藏
页码:696 / 703
页数:8
相关论文
共 50 条
  • [1] Semiquantitative measurement of pulmonary hilar gallium-67 uptake using single photon emission computed tomography/computed tomography for the diagnosis of autoimmune pancreatitis
    Momose, Mitsuhiro
    Kadoya, Masumi
    Yano, Kesato
    Miyasaka, Tadashi
    Fujinaga, Yasunari
    Matsushita, Tsuyoshi
    Yanagisawa, Shin
    Hamano, Hideaki
    Kawa, Shigeyuki
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (10) : 733 - 739
  • [2] Semiquantitative measurement of pulmonary hilar gallium-67 uptake using single photon emission computed tomography/computed tomography for the diagnosis of autoimmune pancreatitis
    Mitsuhiro Momose
    Masumi Kadoya
    Kesato Yano
    Tadashi Miyasaka
    Yasunari Fujinaga
    Tsuyoshi Matsushita
    Shin Yanagisawa
    Hideaki Hamano
    Shigeyuki Kawa
    Japanese Journal of Radiology, 2010, 28 : 733 - 739
  • [3] Examination of cross-calibration and concentration linearity with quantitative gallium-67 single-photon emission computed tomography: phantom experiment
    Takahashi, Yoshiyuki
    Tsuchitani, Tatsuya
    Shibayama, Mitsuhiro
    Ikeda, Takashi
    Kotoura, Noriko
    Kitajima, Kazuhiro
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (04) : 385 - 391
  • [4] Gallium-67 Single-Photon Emission Computed Tomography Affects Management of Infections of Left Ventricular Assist Devices
    Puius, Yoram A.
    Parkar, Fauziya
    Tlamsa, Aileen P.
    Nistico, Justin A.
    Muggia, Victoria A.
    Minamoto, Grace Y.
    Jorde, Ulrich P.
    Goldstein, Daniel J.
    Moadel, Renee M.
    ASAIO JOURNAL, 2021, 67 (07) : 746 - 751
  • [5] Diagnosis of Prosthetic Aortic Valve Endocarditis With Gallium-67 Citrate Single-Photon Emission Computed Tomography/Computed Tomography Hybrid Imaging Using Software Registration
    Yavari, Arash
    Ayoub, Tariq
    Livieratos, Lefteris
    Raman, Vivek
    McWilliams, Eric T.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2009, 2 (06) : E41 - U105
  • [6] Applying standardized uptake values in gallium-67-citrate single-photon emission computed tomography/computed tomography studies and their correlation with blood test results in representative organs
    Toriihara, Akira
    Daisaki, Hiromitsu
    Yamaguchi, Akihiro
    Yoshida, Katsuya
    Isogai, Jun
    Tateishi, Ukihide
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (08) : 720 - 724
  • [7] Technetium-99m depreotide imaging by single photon emission tomography/low resolution computed tomography in malignant lymphomas: comparison with gallium-67 citrate
    Apostolopoulos, Dimitris J.
    Papandrianos, Nikolaos I.
    Symeonidis, Argiris
    Spyridonidis, Tryfon
    Alexiou, Sotiria
    Zampakis, Petros
    Savvopoulos, Christos
    Vassilakos, Pavlos J.
    Matsouka, Panagiota
    ANNALS OF NUCLEAR MEDICINE, 2010, 24 (09) : 639 - 647
  • [8] Technetium-99m depreotide imaging by single photon emission tomography/low resolution computed tomography in malignant lymphomas: comparison with gallium-67 citrate
    Dimitris J. Apostolopoulos
    Nikolaos I. Papandrianos
    Argiris Symeonidis
    Tryfon Spyridonidis
    Sotiria Alexiou
    Petros Zampakis
    Christos Savvopoulos
    Pavlos J. Vassilakos
    Panagiota Matsouka
    Annals of Nuclear Medicine, 2010, 24 : 639 - 647
  • [9] Automated classification of increased uptake regions in bone single-photon emission computed tomography/computed tomography images using three-dimensional deep convolutional neural network
    Tsujimoto, Masakazu
    Teramoto, Atsushi
    Dosho, Masakazu
    Tanahashi, Shingo
    Fukushima, Ayami
    Ota, Seiichiro
    Inui, Yoshitaka
    Matsukiyo, Ryo
    Obama, Yuuki
    Toyama, Hiroshi
    NUCLEAR MEDICINE COMMUNICATIONS, 2021, 42 (08) : 877 - 883
  • [10] Clinical Applications of Technetium-99m Quantitative Single-Photon Emission Computed Tomography/Computed Tomography
    Lee, Won Woo
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 53 (03) : 172 - 181