Comparison of Glaucoma Detection Performance of Binocular Perimetry Screening Program Using imo Perimetry With Frequency Doubling Technology

被引:0
|
作者
Nishijima, Euido [1 ]
Hosaka, Daisuke [1 ,2 ]
Ogawa, Shumpei [1 ,3 ]
Itoh, Yoshinori [1 ]
Noro, Takahiko [1 ]
Okude, Sachiyo [1 ]
Sano, Kei [1 ]
Yoshikawa, Keiji [1 ,4 ]
Tatemichi, Masayuki [5 ]
Nakano, Tadashi [1 ]
机构
[1] Jikei Univ, Dept Ophthalmol, Sch Med, 3-25-8 Nishi Shimbashi,Minato Ku, Tokyo 1058461, Japan
[2] Machida Municipal Hosp, Dept Ophthalmol, Tokyo, Japan
[3] Atsugi City Hosp, Dept Ophthalmol, Atsugi, Kanagawa, Japan
[4] Yoshikawa Eye Clin, Tokyo, Japan
[5] Tokai Univ, Dept Prevent Med, Sch Med, Isehara, Japan
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2024年 / 13卷 / 08期
基金
日本学术振兴会;
关键词
screening; visual field; imo perimetry; glaucoma; RISK-FACTORS; PREVALENCE; BURDEN;
D O I
10.1167/tvst.13.8.9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We aimed to preliminarily compare the glaucoma detection accuracy of a head-mounted binocular visual perimeter "imo" screening program (ISP) with that of frequency doubling technology (FDT). Methods: This multicenter, diagnostic accuracy study based on prospectively collected data included 76 non-glaucoma (including pre-perimetric glaucoma) eyes and 92 glaucomatous eyes from patients visiting two hospitals. Patients underwent ISP and FDT (C-20-1 screening program) on the same day. Diagnostic efficacy was evaluated using receiver operating characteristic curves and areas under the curve (AUCs). In addition, we compared the ISP and FDT testing times. Results: AUC values for ISP versus FDT were as follows: (1) mild-stage glaucoma (mean deviation [MD] > -6 dB), 0.82 (95% confidence interval [CI], 0.75-0.88) versus 0.76 (95% CI, 0.68-0.83); moderate-stage glaucoma (-6 dB >= MD >= -12 dB), 0.98 (95% CI, 0.95- 1.00) versus 0.96(95% CI, 0.93-1.00); and advanced-stage glaucoma (-12 dB > MD), 1.00 (95% CI, 1.00-1.00) versus 0.99(95% CI, 0.98-1.00). In addition, mild-stage glaucoma was classified into two stages (MD > -3 D) and (-3 D >= MD > -6 D). AUC values were 0.81 (95% CI, 0.73-0.88) versus 0.76 (95% CI, 0.68-0.84) for MD > -3 D and 0.86 (95% CI, 0.77- 0.94) versus 0.73 (95% CI, 0.61-0.86) for -3 D >= MD > -6 D. The testing time for the ISP was significantly shorter than that of FDT for all glaucoma stages (P < 0.001). Conclusions: The ISP demonstrates non-inferiority in detecting glaucoma and has a shorter testing time compared with FDT. These findings provide evidence for applied further studies on large-scale population-based glaucoma screening. Translational Relevance: Our study provides a non-inferior and quicker glaucoma screening than existing tools.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Structure-Function Relationship between Frequency-Doubling Technology Perimetry and Optical Coherence Tomography in Glaucoma
    Fuertes-Lazaro, Isabel
    Sanchez-Cano, Ana
    Ferreras, Antonio
    Ferrandez, Blanca
    Calvo, Pilar
    Abadia, Beatriz
    Otin, Sofia
    Pablo, Luis E.
    OPHTHALMOLOGICA, 2014, 232 (04) : 230 - 238
  • [42] Learning effect and measurement variability in frequency-doubling technology perimetry in chronic open-angle glaucoma
    Matsuo, H
    Tomita, G
    Suzuki, Y
    Araie, M
    JOURNAL OF GLAUCOMA, 2002, 11 (06) : 467 - 473
  • [43] Laterality of the performance of glaucoma mass screening using frequency-doubling technology
    Tatemichi, M
    Nakano, T
    Tanaka, K
    Hayashi, T
    Nawa, T
    Iwasaki, A
    Miyamoto, T
    Hiro, H
    Sugita, M
    JOURNAL OF GLAUCOMA, 2003, 12 (03) : 221 - 225
  • [44] Learning effect in visual field testing of healthy subjects using Humphrey Matrix frequency doubling technology perimetry
    Pierre-Filho, P. de T.
    Gomes, P. R.
    Pierre, E. T.
    Pierre, L. M.
    EYE, 2010, 24 (05) : 851 - 856
  • [45] Frequency doubling perimetry screening mode compared to the full-threshold mode
    Stoutenbeek, R
    Heeg, GP
    Jansonius, NM
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2004, 24 (06) : 493 - 497
  • [46] Learning effect in visual field testing of healthy subjects using Humphrey Matrix frequency doubling technology perimetry
    P de T Pierre-Filho
    P R Gomes
    E T Pierre
    L M Pierre
    Eye, 2010, 24 : 851 - 856
  • [47] Comparison of Humphrey Matrix Frequency Doubling Technology to Standard Automated Perimetry in Neuro-ophthalmic Disease
    Yoon, Michael K.
    Hwang, Thomas N.
    Day, Shelley
    Hong, Jenny
    Porco, Travis
    McCulley, Timothy J.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2012, 19 (02) : 211 - 215
  • [48] Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry
    Cesareo, Massimo
    Martucci, Alessio
    Ciuffoletti, Elena
    Mancino, Raffaele
    Cerulli, Angelica
    Sorge, Roberto P.
    Martorana, Alessandro
    Sancesario, Giuseppe
    Nucci, Carlo
    FRONTIERS IN NEUROSCIENCE, 2015, 9
  • [49] Detection of ocular disease by a vision-centre technician and the role of frequency-doubling technology perimetry in this setting
    Thomas, Ravi
    Naveen, Shoba
    Nirmalan, Praveen K.
    Parikh, Rajul
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (02) : 214 - 218
  • [50] Learning effect of Humphrey Matrix Frequency Doubling Technology perimetry in patients with ocular hypertension
    Centofanti, Marco
    Fogagnolo, Paolo
    Oddone, Francesco
    Orzalesi, Nicola
    Vetrugno, Michele
    Manni, Gianluca
    Rossetti, Luca
    JOURNAL OF GLAUCOMA, 2008, 17 (06) : 436 - 441