Comparison of Glaucoma Detection Performance of Binocular Perimetry Screening Program Using imo Perimetry With Frequency Doubling Technology

被引:0
|
作者
Nishijima, Euido [1 ]
Hosaka, Daisuke [1 ,2 ]
Ogawa, Shumpei [1 ,3 ]
Itoh, Yoshinori [1 ]
Noro, Takahiko [1 ]
Okude, Sachiyo [1 ]
Sano, Kei [1 ]
Yoshikawa, Keiji [1 ,4 ]
Tatemichi, Masayuki [5 ]
Nakano, Tadashi [1 ]
机构
[1] Jikei Univ, Dept Ophthalmol, Sch Med, 3-25-8 Nishi Shimbashi,Minato Ku, Tokyo 1058461, Japan
[2] Machida Municipal Hosp, Dept Ophthalmol, Tokyo, Japan
[3] Atsugi City Hosp, Dept Ophthalmol, Atsugi, Kanagawa, Japan
[4] Yoshikawa Eye Clin, Tokyo, Japan
[5] Tokai Univ, Dept Prevent Med, Sch Med, Isehara, Japan
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2024年 / 13卷 / 08期
基金
日本学术振兴会;
关键词
screening; visual field; imo perimetry; glaucoma; RISK-FACTORS; PREVALENCE; BURDEN;
D O I
10.1167/tvst.13.8.9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We aimed to preliminarily compare the glaucoma detection accuracy of a head-mounted binocular visual perimeter "imo" screening program (ISP) with that of frequency doubling technology (FDT). Methods: This multicenter, diagnostic accuracy study based on prospectively collected data included 76 non-glaucoma (including pre-perimetric glaucoma) eyes and 92 glaucomatous eyes from patients visiting two hospitals. Patients underwent ISP and FDT (C-20-1 screening program) on the same day. Diagnostic efficacy was evaluated using receiver operating characteristic curves and areas under the curve (AUCs). In addition, we compared the ISP and FDT testing times. Results: AUC values for ISP versus FDT were as follows: (1) mild-stage glaucoma (mean deviation [MD] > -6 dB), 0.82 (95% confidence interval [CI], 0.75-0.88) versus 0.76 (95% CI, 0.68-0.83); moderate-stage glaucoma (-6 dB >= MD >= -12 dB), 0.98 (95% CI, 0.95- 1.00) versus 0.96(95% CI, 0.93-1.00); and advanced-stage glaucoma (-12 dB > MD), 1.00 (95% CI, 1.00-1.00) versus 0.99(95% CI, 0.98-1.00). In addition, mild-stage glaucoma was classified into two stages (MD > -3 D) and (-3 D >= MD > -6 D). AUC values were 0.81 (95% CI, 0.73-0.88) versus 0.76 (95% CI, 0.68-0.84) for MD > -3 D and 0.86 (95% CI, 0.77- 0.94) versus 0.73 (95% CI, 0.61-0.86) for -3 D >= MD > -6 D. The testing time for the ISP was significantly shorter than that of FDT for all glaucoma stages (P < 0.001). Conclusions: The ISP demonstrates non-inferiority in detecting glaucoma and has a shorter testing time compared with FDT. These findings provide evidence for applied further studies on large-scale population-based glaucoma screening. Translational Relevance: Our study provides a non-inferior and quicker glaucoma screening than existing tools.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, SITA Standard and SITA Fast perimetry in perimetrically inexperienced individuals
    de Tarso Ponte Pierre-Filho, Paulo
    Schimiti, Rui Barroso
    Cabral de Vasconcellos, Jose Paulo
    Costa, Vital Paulino
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (03): : 345 - 350
  • [32] Comparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss
    Saric, D
    Mandic, Z
    Ivekovic, R
    Geber, MZ
    Bencic, G
    Tomic, Z
    Grgic, D
    COLLEGIUM ANTROPOLOGICUM, 2005, 29 : 111 - 113
  • [33] Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients
    Folkert K. Horn
    Nina Wakili
    Anselm M. Jünemann
    Matthias Korth
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2002, 240 : 658 - 665
  • [34] Test-retest variability in glaucoma patients tested with C-20-1 screening-mode frequency doubling technology perimetry
    Brush, MB
    Chen, PP
    JOURNAL OF GLAUCOMA, 2004, 13 (04) : 273 - 277
  • [35] The Validity of Screening For Open-angle Glaucoma in High-risk Populations With Single-test Screening Mode Frequency Doubling Technology Perimetry (FDT)
    Fansi, Alvine A. Kamdeu
    Li, Gisele
    Harasymowycz, Paul J.
    JOURNAL OF GLAUCOMA, 2011, 20 (03) : 167 - 171
  • [36] Relationship between second-generation frequency doubling technology and standard automated perimetry in patients with glaucoma
    Zarkovic, Andrea
    Mora, Justin
    McKelvie, James
    Gamble, Greg
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (09) : 808 - 811
  • [37] Insights for mfVEPs from perimetry using large spatial frequency-doubling and near frequency-doubling stimuli in glaucoma
    Abdullah, Siti Nurliyana
    Sanderson, Gordon F.
    Husni, Mohd Aziz
    Maddess, Ted
    DOCUMENTA OPHTHALMOLOGICA, 2020, 141 (01) : 45 - 55
  • [38] Insights for mfVEPs from perimetry using large spatial frequency-doubling and near frequency-doubling stimuli in glaucoma
    Siti Nurliyana Abdullah
    Gordon F. Sanderson
    Mohd Aziz Husni
    Ted Maddess
    Documenta Ophthalmologica, 2020, 141 : 45 - 55
  • [39] Frequency doubling technology perimetry using a 24-2 stimulus presentation pattern
    Johnson, CA
    Cioffi, GA
    Van Buskirk, EM
    OPTOMETRY AND VISION SCIENCE, 1999, 76 (08) : 571 - 581
  • [40] The Groningen Longitudinal Glaucoma Study. II. A prospective comparison of frequency doubling perimetry, the GDx nerve fibre analyser and standard automated perimetry in glaucoma suspect patients
    Jansonius, Nomdo M.
    Heeg, Govert P.
    ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 429 - 432