Magnetic solid-phase extraction technique based on Fe3O4@coPPy-PTH nanocomposite for extraction of cobalt, chromium, and nickel prior to determination by micro-sample injection system-flame atomic absorption spectrometry in alcoholic and nonalcoholic beverages

被引:1
|
作者
Kucuksakalli, Melike [1 ]
Salamat, Qamar [1 ]
Tireli, Buket [1 ]
Elci, Sukru Gokhan [1 ]
机构
[1] Pamukkale Univ, Fac Technol, Dept Biomed Engn, Denizli, Turkiye
关键词
Fe3O4@coPPy-PTH nanocomposite; metal ions; microsample injection system-flame atomic absorption spectrometry; beer; wine; LIQUID-LIQUID MICROEXTRACTION; FE3O4; NANOPARTICLES; TRACE-ELEMENTS; PRECONCENTRATION; SEPARATION; COPPER; LEAD;
D O I
10.55730/1300-0527.3683
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel Fe3O4@coPPy-PTH nanocomposite-based sorbent was prepared via in-situ oxidative polymerization using Fe3O4 nanoparticles with spherical and flower-like morphologies of thiophene and pyrrole as the feedstocks. The synthesized nanocomposite utilized sensitive extraction and determination of the metal ions Co(II), Cr(III), and Ni(II) without a chelating agent, followed by a micro-sample injection system-flame atomic absorption spectrometer (MIS-FAAS). The composition and morphology of Fe3O4@coPPy-PTH nanocomposite were characterized by advanced spectroscopic and imaging techniques like SEM and FT-IR. SEM observations showed the size of Fe3O4 nanoparticles changed from 30 nm to 120 nm in diameter after the copolymer (PPy-PTH) coating. The Fe3O4@coPPy-PTH nanocomposite possesses good dispersion properties and acid stability in strong acid solutions. For effective extraction of studied analytes, the influence of sample pH, volume of sample solution and eluent, amount of adsorbent, and interference of coexisting metal ions were optimized. Under the optimum conditions, preconcentration factors were obtained to be 25 for all analytes. The calibration curves were linear in the range of 0.0-10.0 mu g L-1 with coefficients of determination (R-2) more than 0.9957 for all three analytes. Limits of detection (S/N=3) were calculated in the range of 0.17-0.23 mu g L-1. Precisions, expressed as relative standard deviations (RSD), were lower than 3.0 %, and relative recoveries were obtained in the range of 88.6-103.6 %. The proposed method (Fe3O4@coPPy-PTH/MSPE/MIS-FAAS) was successfully applied to extract and determine studied metal ions in beer, wine, and nonalcoholic beverage samples.
引用
收藏
页码:620 / 630
页数:12
相关论文
共 26 条
  • [21] Determination of lead and cadmium in water samples by magnetic solid-phase extraction with iron oxide@silicon oxide-graphene oxide (Fe3O4@SiO2-GO) hybrid magnetic nanoparticles and microinjection sampling flame atomic absorption spectrometry
    Baykal, Gulser
    Kazan, Damla
    Seval, Kadir
    Bulut, Duygu Takanoglu
    Elci, Sukru Gokhan
    Divrikli, Umit
    Akdogan, Abdullah
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2021, 50 (03) : 288 - 305
  • [22] Selective separation and determination of the synthetic colorants in beverages by magnetic solid-phase dispersion extraction based on a Fe3O4/reduced graphene oxide nanocomposite followed by high-performance liquid chromatography with diode array detection
    Wang, Xi
    Chen, Ning
    Han, Qing
    Yang, Zaiyue
    Wu, Jinhua
    Xue, Cheng
    Hong, Junli
    Zhou, Xuemin
    Jiang, Huijun
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (12) : 2167 - 2173
  • [23] Accurate and sensitive determination of cobalt in urine samples using deep eutectic solvent-assisted magnetic colloidal gel-based dispersive solid phase extraction prior to slotted quartz tube equipped flame atomic absorption spectrometry
    Tülay Borahan
    Buse Tuğba Zaman
    Gözde Özzeybek
    Sezgin Bakırdere
    Chemical Papers, 2021, 75 : 2937 - 2944
  • [24] Accurate and sensitive determination of cobalt in urine samples using deep eutectic solvent-assisted magnetic colloidal gel-based dispersive solid phase extraction prior to slotted quartz tube equipped flame atomic absorption spectrometry
    Borahan, Tulay
    Zaman, Buse Tugba
    Ozzeybek, Gozde
    Bakirdere, Sezgin
    CHEMICAL PAPERS, 2021, 75 (06): : 2937 - 2944
  • [25] Ligandless surfactant mediated solid phase extraction combined with Fe3O4 nano-particle for the preconcentration and determination of cadmium and lead in water and soil samples followed by flame atomic absorption spectrometry: Multivariate strategy
    Jalbani, N.
    Soylak, M.
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2014, 102 : 174 - 178
  • [26] Magnetic mixed hemimicelles dispersive solid-phase extraction based on ionic liquid-coated attapulgite/polyaniline-polypyrrole/Fe3O4 nanocomposites for determination of acaricides in fruit juice prior to high-performance liquid chromatography-diode array detection
    Yang, Xiaoling
    Qiao, Kexin
    Liu, Fang
    Wu, Xiaoling
    Yang, Miyi
    Li, Jing
    Gao, Haixiang
    Zhang, Sanbing
    Zhou, Wenfeng
    Lu, Runhua
    TALANTA, 2017, 166 : 93 - 100