CT Angiography for Aortic Arch Anomalies: Prevalence, Diagnostic Efficacy, and Illustrative Findings

被引:0
|
作者
Baz, Radu Octavian [1 ,2 ]
Refi, Deria [1 ]
Scheau, Cristian [3 ,4 ]
Axelerad, Any [5 ]
Baz, Radu Andrei [1 ]
Niscoveanu, Cosmin [1 ,2 ]
机构
[1] Sf Apostol Andrei Cty Emergency Hosp, Clin Lab Radiol & Med Imaging, Constanta 900591, Romania
[2] Ovidius Univ, Fac Med, Dept Radiol & Med Imaging, Constanta 900527, Romania
[3] Carol Davila Univ Med & Pharm, Dept Physiol, Bucharest 050474, Romania
[4] Foisor Clin Hosp Orthopaed Traumatol & Osteoarticu, Dept Radiol & Med Imaging, Bucharest 021382, Romania
[5] Ovidius Univ, Fac Med, Dept Neurol, Constanta 900527, Romania
关键词
aortic arch anomalies; right aortic arch; coarctation of aorta; pseudocoarctation; ductus diverticulum; aberrant subclavian artery; vascular anatomical variants; computed tomography; imaging; LEFT SUBCLAVIAN ARTERY; CONGENITAL-ANOMALIES; COARCTATION; PSEUDOCOARCTATION; MANAGEMENT; ASSOCIATION; VARIANTS; ANEURYSM; SURGERY; MRI;
D O I
10.3390/diagnostics14171851
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aortic arch anomalies encompass a diverse spectrum of conditions. Elucidating the prevalence of these anomalies, their impact on patient wellbeing, and the most effective diagnostic tools are crucial steps in ensuring optimal patient care. This paper aims to explore the various presentations of aortic arch anomalies, emphasizing the remarkable utility of computed tomography (CT) angiography in their definitive diagnosis and characterization. We conducted a retrospective study on patients who were submitted to the CT angiography of the thoracic aorta or supra-aortic trunks, or the contrast-enhanced CT scans of the thorax and/or cervical region between January 2021 and February 2024 in our Hospital. Out of the total of 2350 patients, 18 were diagnosed with aortic arch anomalies, with an average age of approximately 55 years. The aortic arch anomalies identified in the study were as follows: left aortic arch with the aberrant origin of the right subclavian artery, right aortic arch (types I and II), double aortic arch, aortic coarctation, aortic pseudocoarctation, and ductus diverticulum. Although often asymptomatic, aortic arch anomalies require recognition and CT using advanced post-processing techniques is the optimal diagnostic method with the ability to also identify other associated cardiac or vascular malformations.
引用
收藏
页数:22
相关论文
共 46 条
  • [41] Diagnostic efficacy of gadoxetic acid (Primovist)-enhanced MRI and spiral CT for a therapeutic strategy:: comparison with intraoperative and histopathologic findings in focal liver lesions
    Hammerstingl, Renate
    Huppertz, Alexander
    Breuer, Josy
    Balzer, Thomas
    Blakeborough, Anthony
    Carter, Rick
    Fuste, Lluis Castells
    Heinz-Peer, Gertraud
    Judmaier, Werner
    Laniado, Michael
    Manfredi, Riccardo M.
    Mathieu, Didier G.
    Mueller, Dieter
    Mortele, Koenraad
    Reimer, Peter
    Reiser, Maximilian F.
    Robinson, Philip J.
    Shamsi, Kohkan
    Strotzer, Michael
    Taupitz, Matthias
    Tombach, Bernd
    Valeri, Gianluca
    van Beers, Bernhard E.
    Vogl, Thomas J.
    EUROPEAN RADIOLOGY, 2008, 18 (03) : 457 - 467
  • [42] Incidental Findings on Pre-procedural CT Imaging for Transcatheter Aortic Valve Replacement- Prevalence and Categorization Based on the Impact on Procedure Planning and Patient Care
    Najafpour, Elham
    Vargas, Daniel
    Sridhar, Sreevathsan
    Maniar, Hersh
    Zajarias, Alan
    Javidan-Nejad, Cylen
    CIRCULATION, 2013, 128 (22)
  • [43] Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement
    Chang, Suyon
    Jung, Jung Im
    Beck, Kyongmin Sarah
    Chang, Kiyuk
    Kim, Yaeni
    Han, Kyunghwa
    KOREAN JOURNAL OF RADIOLOGY, 2024, 25 (07) : 634 - 643
  • [44] Iodixanol in multidetector-row computed tomography angiography (MDCTA): Diagnostic accuracy for abdominal aorta and abdominal aortic major-branch diseases using four-, eight- and 16-detector-row CT scanners
    Nonent, M.
    Thouveny, F.
    Simons, P.
    Cappeliez, O.
    Reiser, M. F.
    Duddalwar, V.
    Bonomo, L.
    Liessi, G.
    ACTA RADIOLOGICA, 2007, 48 (01) : 48 - 58
  • [45] Pre-procedural high-pitch coronary CT angiography assessment of patients undergoing transcatheter aortic valve implantation (TAVI) without patient-specific adjustment: analysis of diagnostic performance
    Seitz, P.
    Krieghoff, C.
    Gottschling, S.
    Luecke, C.
    Abdel-Wahab, M.
    Holzhey, D.
    Gohmann, R. F.
    Gutberlet, M.
    CLINICAL RADIOLOGY, 2021, 76 (11) : 862.e29 - 862.e36
  • [46] 64-Slice CT angiography of the abdominal aorta and abdominal arteries: comparison of the diagnostic efficacy of iobitridol 350 mgI/ml versus iomeprol 400 mgI/ml in a prospective, randomised, double-blind multi-centre trial
    Loewe, Christian
    Becker, Christoph R.
    Berletti, Riccardo
    Cametti, Carlo Alberto
    Caudron, Jerome
    Coudyzer, Walter
    De Mey, Johan
    Favat, Massimo
    Heautot, Jean-Francois
    Heye, Sam
    Hittinger, Markus
    Larralde, Antoine
    Lestrat, Jean-Pierre
    Marangoni, Roberto
    Nieboer, Koenraad
    Reimer, Peter
    Schwarz, Martin
    Schernthaner, Melanie
    Lammer, Johannes
    EUROPEAN RADIOLOGY, 2010, 20 (03) : 572 - 583