Analysis of internal behavior of electrochemical hydrogen compressors at high pressures

被引:1
作者
Kim, Min Soo [1 ]
Chu, Chan Ho [1 ]
Kim, Young Ki [1 ]
Kim, Minsung [2 ]
Lee, Do Hyun [1 ]
Kim, Seonyeob [3 ]
Kim, Dong Kyu [1 ,4 ]
机构
[1] Chung Ang Univ, Sch Mech Engn, Seoul 06974, South Korea
[2] Chung Ang Univ, Sch Energy Syst Engn, Seoul 06974, South Korea
[3] Korea Inst Machinery & Mat, Dept Mobil Power Res, Daejeon 04103, South Korea
[4] Chung Ang Univ, Sch Comp Sci & Engn, Seoul 06974, South Korea
基金
新加坡国家研究基金会;
关键词
Hydrogen; Electrochemical compressor; Polymer electrolyte membrane; Parametric study; Hydrogen back-diffusion; Efficiency; FUEL-CELL; EXPERIMENTAL VALIDATION; NAFION MEMBRANES; PERFORMANCE; TECHNOLOGIES; DIFFUSION;
D O I
10.1016/j.renene.2024.121165
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We examined the internal behavior of an electrochemical hydrogen compressor under high-pressure conditions. In doing so, we focused on the changes in compressor efficiency and power consumption in response to intensified hydrogen back-diffusion under high pressures and various values of other parameters. First, as the operating temperature increased, the power consumed to achieve the same pressure ratio increased. This increased in power consumption was attributed to the fact that as the temperature increased, hydrogen back-diffusion intensified, which necessitated a net forward flux and induced flow losses. Second, as the relative humidity increased, power consumption decreased, and compressor efficiency increased. Although higher relative humidity intensifies back-diffusion, leading to flow losses, the accompanying significant decrease in ohmic losses increases compressor efficiency. By adjusting factors such as temperature and relative humidity, compressor efficiency can potentially be increased by up to 1.78 times. At high pressure ratios, hydrogen back-diffusion was inherently strong, and it became stronger at higher temperatures and relative humidities. Therefore, the compressor was more efficient when it was operated at lower temperatures and higher relative humidities. At the optimal operating temperature of 50 degrees C and 100 % relative humidity, the compressor efficiency peaked at 97.507 % when the pressure ratio was 100.
引用
收藏
页数:11
相关论文
共 45 条
  • [1] Abdulla A.Y., 2009, The Electro-chemical Purification of Hydrogen using Polymer Electrolyte Membrane Fuel Cells
  • [2] American Automatic Control Council, 2008, P 2008 AM CONTR C WE
  • [3] [Anonymous], 2011, Fuel Cells Bulletin, V2011, P8, DOI DOI 10.1016/S1464-2859(11)70283-8
  • [4] Effects of operating parameters on hydrogen crossover rate through Nafion® membranes in polymer electrolyte membrane fuel cells
    Baik, Kyung Don
    Hong, Bo Ki
    Kim, Min Soo
    [J]. RENEWABLE ENERGY, 2013, 57 : 234 - 239
  • [5] Bampaou M., 2018, CHEM ENG TRANS, V70, P1213, DOI [10.3303/CET1870203, DOI 10.3303/CET1870203]
  • [6] books.google, Principles of heat transfer in porous Media - Maasoud Kaviany - Google
  • [7] Advances In Electrochemical Hydrogen Compression And Purification
    Bouwman, P. J.
    [J]. POLYMER ELECTROLYTE FUEL CELLS 16 (PEFC 16), 2016, 75 (14): : 503 - 510
  • [8] Electrochemical Hydrogen Compression
    Bouwman, P. J.
    Konink, J.
    Semerel, D.
    Raymakers, L.
    Koeman, M.
    Dalhuijsen, W.
    Milacic, E.
    [J]. POLYMER ELECTROLYTE FUEL CELLS 14, 2014, 64 (03): : 1009 - 1018
  • [9] Effect of back-diffusion on the performance of an electrochemical hydrogen compressor
    Chouhan, Ashish
    Bahar, Bamdad
    Prasad, Ajay K.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (19) : 10991 - 10999
  • [10] Dale N., 2008, Modeling and Analysis of Electrochemical Hydrogen Compression