Cost-effectiveness of Micra™ VR leadless pacemaker in patients with bradycardia and atrial fibrillation in Australia

被引:2
作者
Makino, Koji [1 ]
Mudge, Mia [1 ]
Hill, Michelle [2 ]
Zaunmayr, Chelsea [1 ]
Tilden, Dominic [1 ]
机构
[1] THEMA Consulting Pty Ltd, Suite 9-02,52 Alfred St, Milsons Point, NSW 2061, Australia
[2] Medtron Australasia Pty Ltd, Macquarie Pk, NSW, Australia
关键词
atrial fibrillation; bradycardia; cost-effectiveness; leadless pacemaker; pacemaker; MORTALITY; SCORES; RISK;
D O I
10.1002/joa3.13145
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Micra (TM) VR Transcatheter Pacing System (Micra VR) is a single-chamber transcatheter leadless pacemaker. Absence of leads and subcutaneous pocket reduces or completely eliminates the risk of complications associated with the conventional transvenous pacemakers (TVPM). When compared with TVPM, the leadless technology provides a quicker postimplantation recovery and causes less cosmetic concerns/discomfort providing better patient experiences in the long run. We performed a modeled cost-utility analysis of Micra VR versus TVPM for the management of patients with bradycardia. Methods We developed a Markov model comparing Micra VR to TVPM over the device battery life of 17 years. Key data inputs were drawn from the MICRA Coverage with Evidence Development (CED) study. Costs were obtained from Australian sources. The analysis is from the perspective of the Australian healthcare system. Results The risks of complications, including device-related events, in real-world clinical practice were relatively low for TVPM. The magnitude of cost savings arising from risk reductions provided by Micra VR was however sizable, offsetting roughly a quarter of its additional device cost. Over the 17-year model period, Micra VR was associated with an estimated incremental cost of A$4277 and an incremental quality-adjusted life years (QALYs) of 0.09 when compared with TVPM, yielding an incremental cost-effectiveness ratio of A$47 379 per QALY gain. Conclusions Micra VR is likely to offer a cost-effective alternative to the conventional TVPM technology for the management of patients with bradycardia.
引用
收藏
页码:1481 / 1489
页数:9
相关论文
共 25 条
[1]   Deriving an Algorithm to Convert the Eight Mean SF-36 Dimension Scores into a Mean EQ-5D Preference-Based Score from Published Studies (Where Patient Level Data Are Not Available) [J].
Ara, Roberta ;
Brazier, John .
VALUE IN HEALTH, 2008, 11 (07) :1131-1143
[2]  
Australian Bureau of Statistics, 2023, LIFE TABLES2019 2021
[3]   Risk Factors for Infections Involving Cardiac Implanted Electronic Devices [J].
Birnie, David H. ;
Wang, Jia ;
Alings, Marco ;
Philippon, Francois ;
Parkash, Ratika ;
Manlucu, Jaimie ;
Angaran, Paul ;
Rinne, Claus ;
Coutu, Benoit ;
Low, R. Aaron ;
Essebag, Vidal ;
Morillo, Carlos ;
Redfearn, Damian ;
Toal, Satish ;
Becker, Giuliano ;
Degrace, Michel ;
Thibault, Bernard ;
Crystal, Eugene ;
Tung, Stanley ;
LeMaitre, John ;
Sultan, Omar ;
Bennett, Matthew ;
Bashir, Jamil ;
Ayala-Paredes, Felix ;
Gervais, Philippe ;
Rioux, Leon ;
Hemels, Martin E. W. ;
Bouwels, Leon H. R. ;
Exner, Derek V. ;
Dorian, Paul ;
Connolly, Stuart J. ;
Longtin, Yves ;
Krahn, Andrew D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (23) :2845-2854
[4]   European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS) [J].
Blomstrom-Lundqvist, Carina ;
Traykov, Vassil ;
Erba, Paola Anna ;
Burri, Haran ;
Nielsen, Jens Cosedis ;
Bongiorni, Maria Grazia ;
Poole, Jeanne ;
Boriani, Giuseppe ;
Costa, Roberto ;
Deharo, Jean-Claude ;
Epstein, Laurence M. ;
Saghy, Laszlo ;
Snygg-Martin, Ulrika ;
Starck, Christoph ;
Tascini, Carlo ;
Strathmore, Neil .
EUROPACE, 2020, 22 (04) :515-516
[5]   Cost-Effectiveness Analyses of an Absorbable Antibacterial Envelope for Use in Patients at Increased Risk of Cardiac Implantable Electronic Device Infection in Germany, Italy, and England [J].
Boriani, Giuseppe ;
Kennergren, Charles ;
Tarakji, Khaldoun G. ;
Wright, David J. ;
Ahmed, Fozia Z. ;
McComb, Janet M. ;
Goette, Andreas ;
Blum, Thomas ;
Biffi, Mauro ;
Green, Michelle ;
Shore, Judith ;
Carion, Phuong Lien ;
Wilkoff, Bruce L. .
VALUE IN HEALTH, 2021, 24 (07) :930-938
[6]   Quality of life of patients undergoing conventional vs leadless pacemaker implantation: A multicenter observational study [J].
Cabanas-Grandio, Pilar ;
Garcia Campo, Enrique ;
Bisbal, Felipe ;
Garcia-Seara, Javier ;
Pachon, Marta ;
Juan-Salvadores, Pablo ;
Paredes, Emilio ;
Molinero, Asier ;
Martinez-Sande, Jose Luis ;
Arias, Miguel Angel ;
Iniguez Romo, Andres .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (01) :330-336
[7]   Leadless versus transvenous single-chamber ventricular pacemakers: 3 year follow-up of the Micra CED study [J].
Crossley, George H. ;
Piccini, Jonathan P. ;
Longacre, Colleen ;
Higuera, Lucas ;
Stromberg, Kurt ;
El-Chami, Mikhael F. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (04) :1015-1023
[8]   Long-term performance of a transcatheter pacing system: 12-Month results from the Micra Transcatheter Pacing Study [J].
Duray, Gabor Z. ;
Ritter, Philippe ;
El-Chami, Mikhael ;
Narasimhan, Calambur ;
Omar, Razali ;
Tolosana, Jose M. ;
Zhang, Shu ;
Soejima, Kyoko ;
Steinwender, Clemens ;
Rapallini, Leonardo ;
Cicic, Aida ;
Fagan, Dedra H. ;
Liu, Shufeng ;
Reynolds, Dwight .
HEART RHYTHM, 2017, 14 (05) :702-709
[9]   Leadless vs. transvenous single-chamber ventricular pacing in the Micra CED study: 2-year follow-up [J].
El-Chami, Mikhael F. ;
Bockstedt, Lindsay ;
Longacre, Colleen ;
Higuera, Lucas ;
Stromberg, Kurt ;
Crossley, George ;
Kowal, Robert C. ;
Piccini, Jonathan P. .
EUROPEAN HEART JOURNAL, 2022, 43 (12) :1207-1215
[10]   Updated performance of the Micra transcatheter pacemaker in the real-world setting: A comparison to the investigational study and a transvenous historical control [J].
El-Chami, Mikhael F. ;
Al-Samadi, Faisal ;
Clementy, Nicolas ;
Garweg, Christophe ;
Luis Martinez-Sande, Jose ;
Piccini, Jonathan P. ;
Iacopino, Saverio ;
Lloyd, Michael ;
Vinolas Prat, Xavier ;
Jacobsen, Michael Dilou ;
Ritter, Philippe ;
Johansen, Jens Brock ;
Tondo, Claudio ;
Liu, Fang ;
Fagan, Dedra H. ;
Eakley, Alyssa K. ;
Roberts, Paul R. .