Optimization of resolution as a simultaneous function of solvent composition, pH and temperature in reversed-phase liquid chromatography

被引:1
|
作者
Caruso, Sebastian J. [1 ]
Cifuente, Pedro N. [1 ]
Castells, Cecilia B. [1 ]
Gagliardi, Leonardo G. [1 ]
机构
[1] Univ Nacl La Plata, Fac Ciencias Exactas, Lab Invest & Desarrollo Metodos Analit LIDMA, CIC PBA,CONICET, Calle 47 Esq 115, RA-1900 La Plata, Argentina
关键词
DRY optimization; FOUR-DIMENSION optimization; LIQUID chromatography; MODELING RETENTION; OVERLAPPED RESOLUTION MAPS; MODELING RETENTION; SEPARATION;
D O I
10.1016/j.aca.2024.342657
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: The latest chromatographic retention models are capable of accurately describe the dependencies of retention over a wide range of experimental conditions. By using a suitable conversion, these models can be transformed into equations expressing the optimization criteria as function of multiples variables. Even though that theoretical models significantly reduce the experimental requirements for optimizations, these models have been barely used. Instead, most optimizations rely on empirical exploration of the relationships between criterions and variables. There is a need for a strategy to reduce the required number of experiments in multivariated optimization of separations, and Fundamental Models offer a clear opportunity for addressing it. Results: A Fundamental Model is used to give the simultaneous dependence of chromatographic retention of seven ionizable pesticides on the three variables: solvent composition, temperature and pH (w, T, pH). Based on few experiments, the 10 parameters required to predict the chromatographic retention of those compounds, taken as model analytes, can be obtained. Two mathematical treatments to convert retentions into resolutions between pairs are used: one considering extracolumn dispersions and other neglecting these contributions. Using the Overlapped Resolutions Maps, extended to four dimensions, two optimal conditions can be found for the two different mathematical conversions. Chromatographic conditions were empirically evaluated obtaining the best results for the optimization considering extracolumn dispersions, proving that this condition is a true optimal. It was demonstrated that any small shift in any of the variables from this true optimal leads to a loss in resolution. Significance: Fundamental Models describing chromatographic retention as a simultaneous function of multiple variables are nowadays very accurate. In this work is demonstrated that these models are useful not only to predict retentions, but also to optimize separations, even in the more challenging mode: isocratic, isothermal and iso-pH. However, the success in the optimization procedure depends also on the proper definition of the mathematical conversion of the Fundamental Models into optimization criteria.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Destructive stationary phase gradients for reversed-phase/hydrophilic interaction liquid chromatography
    Cain, Caitlin N.
    Forzano, Anna, V
    Rutan, Sarah C.
    Collinson, Maryanne M.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1570 : 82 - 90
  • [42] Ion-pairing reversed-phase liquid chromatography fractionation in combination with isotope labeling reversed-phase liquid chromatography-mass spectrometry for comprehensive metabolome profiling
    Guo, Kevin
    Peng, Jun
    Zhou, Ruokun
    Li, Liang
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (23) : 3689 - 3694
  • [43] Modelling of the effect off solute structure and mobile phase pH and composition on the retention of phenoxy acid herbicides in reversed-phase high-performance liquid chromatography
    Aschi, Massimiliano
    DArchivio, Angelo Antonio
    Mazzeo, Pietro
    Pierabella, Mirko
    Ruggieri, Fabrizio
    ANALYTICA CHIMICA ACTA, 2008, 616 (02) : 123 - 137
  • [44] Safer Solvent Blends for Food, Dye, and Environmental Analyses Using Reversed-Phase High Performance Liquid Chromatography
    Nallar, Melisa
    Tenaglia, Nicholas
    Morose, Gregory
    Wong, Hsi-Wu
    CHROMATOGRAPHIA, 2021, 84 (08) : 769 - 780
  • [45] Retention modeling in combined pH/organic solvent gradient reversed-phase HPLC
    Zisi, Ch.
    Fasoula, S.
    Nikitas, P.
    Pappa-Louisi, A.
    ANALYST, 2013, 138 (13) : 3771 - 3777
  • [46] Safer Solvent Blends for Food, Dye, and Environmental Analyses Using Reversed-Phase High Performance Liquid Chromatography
    Melisa Nallar
    Nicholas Tenaglia
    Gregory Morose
    Hsi-Wu Wong
    Chromatographia, 2021, 84 : 769 - 780
  • [47] Modelling flow rate gradient elution in reversed-phase liquid chromatography
    Louisi, A. Pappa
    Nikitas, P.
    Zitrou, A.
    ANALYTICA CHIMICA ACTA, 2006, 573 : 305 - 310
  • [48] Some insights on the description of gradient elution in reversed-phase liquid chromatography
    Jose Baeza-Baeza, Juan
    Celia Garcia-Alvarez-Coque, Maria
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (17) : 2269 - 2277
  • [49] Column equilibration effects in gradient elution in reversed-phase liquid chromatography
    Pappa-Louisi, A.
    Nikitas, P.
    Agrafiotou, P.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) : 97 - 107
  • [50] Wide injection zone compression in gradient reversed-phase liquid chromatography
    Gilar, Martin
    McDonald, Thomas S.
    Johnson, Jay S.
    Murphy, James P.
    Jorgenson, James W.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1390 : 86 - 94