Intraoperative OCT to check the correct postimplant position of Preserflo™

被引:0
作者
Morales-Fernandez, Laura [1 ,2 ]
Perez-Garcia, Pilar [1 ]
Martinez-de-la-Casa, Jose Maria [1 ]
Saenz-Frances, Federico [1 ]
Pascual-Santiago, Marco-Antonio [1 ]
Gines-Gallego, Cristina [1 ]
Garcia-Feijoo, Julian [1 ]
机构
[1] Hosp Clin San Carlos, Inst Deinvest Sanit Hosp Clin San Carlos IdISSC, Ophthalmol Unit, Prof Martin Lagos st, Madrid, Spain
[2] Hosp Univ Quironsalud Madrid, Ophthalmol Unit, Madrid, Spain
关键词
Diagnostic techniques < GLAUCOMA; glaucoma incisional surgery < GLAUCOMA; open angle glaucoma < GLAUCOMA; tube shunts < GLAUCOMA; optics/refraction/instruments < OPTICS / REFRACTION/INSTRUMENTS; OPTICAL COHERENCE TOMOGRAPHY; ENDOTHELIAL-CELL DAMAGE; CORNEAL; ISTENT;
D O I
10.1177/11206721241272169
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction: This study was designed to examine the capacity of intraoperative optical coherence tomography (OCT) to predict the postimplant position of the glaucoma drainage device PreserfloTM. Methods: 13 eyes (mean age 65.42 (14.89) years) underwent PreserfloTM (Santen, Osaka, Japan) placement. Before surgery, participants were subjected to a comprehensive ophthalmic examination (intraocular pressure (IOP), cup to disk ratio (C/D), visual field, OCT, endothelial cell count). Anterior segment OCT scans were obtained intraoperatively using a Rescan 700 OCT system (Carl Zeiss Meditec, Inc., Oberkochen, Germany). One day postsurgery, anterior segment OCT using the Spectralis OCT (Heidelberg Engineering GmbH) was performed in a sitting position to capture the same chamber cross-section as before. The main outcome variables were tube-endothelium distance (T-E) and tube length (TL) in the anterior chamber measured using both OCT systems. Correlation between intraoperative and office measurements was examined through Pearson correlation (r) and intraclass correlation coefficients (ICC). Results: Mean intraoperative and in-office T-E were 625.26 (SD 366.60) versus 561.16 (SD 364.62) mu m respectively (p = 0.540). Intraoperative and in-office anterior chamber TL were 1386 (SD 701.82) and 1433.91 (SD 713.55) mu m, respectively (p = 0.029). Excellent correlation was observed between both sets of T-E (r = 0.992; p = 0.008) and TL (r = 0.984; p = 0.016) values. Both OCT systems showed good agreement yielding ICCs of 0.992 (p < 0.001) for T-E and 0.995 (p = 0.001) for TL. Discussion: Excellent correlation was observed between our intraoperative and postoperative OCT measurements. These results support the usefulness of intraoperative OCT to confirm the correct position of an implanted PreserfloTM microshunt.
引用
收藏
页码:551 / 558
页数:8
相关论文
共 34 条
  • [1] Long-Term Endothelial Safety Profile With iStent Inject in Patients With Open-Angle Glaucoma
    Ahmed, Iqbal Ike K.
    Sheybani, A. R. S. H. A. M.
    DE Francesco, T. I. C. I. A. N. A.
    Lass, Jonathan H.
    Benetz, Beth Ann
    Samuelson, Thomas W.
    Usner, D. A. L. E.
    Katz, L. Jay
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 252 : 17 - 25
  • [2] Intra-operative optical coherence tomography in glaucoma surgery-a systematic review
    Ang, Bryan C. H.
    Lim, Sheng Yang
    Dorairaj, Syril
    [J]. EYE, 2020, 34 (01) : 168 - 177
  • [3] Asam JS., High Resolut Imaging Microsc Ophthalmol Internet, P285
  • [4] Ab-Externo MicroShunt versus Trabeculectomy in Primary Open-Angle Glaucoma One-Year Results from a 2-Year Randomized, Multicenter Study
    Baker, N. Douglas
    Barnebey, Howard S.
    Moster, Marlene R.
    Stiles, Michael C.
    Vold, Steven D.
    Khatana, Anup K.
    Flowers, Brian E.
    Grover, Davinder S.
    Strouthidis, Nicholas G.
    Panarelli, Joseph F.
    [J]. OPHTHALMOLOGY, 2021, 128 (12) : 1710 - 1721
  • [5] Long-term Results of the PRESERFLO MicroShunt in Patients With Primary Open-angle Glaucoma From a Single-center Nonrandomized Study
    Batlle, Juan F.
    Corona, Adalgisa
    Albuquerque, Rachel
    [J]. JOURNAL OF GLAUCOMA, 2021, 30 (03) : 281 - 286
  • [6] Chamard C., 2022, Am J Ophthalmol Case Rep, V25: 101238.
  • [7] Different patterns in the corneal endothelial cell loss after pars plana and pars limbal insertion of the Baerveldt glaucoma implant
    Chihara, Etsuo
    Tanito, Masaki
    Kono, Michihiro
    Matsuda, Akira
    Honda, Rio
    Ishida, Kyoko
    Funaki, Toshinari
    Hamanaka, Teruhiko
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 253 : 12 - 21
  • [8] Dada Tanuj, 2016, J Ophthalmic Vis Res, V11, P452
  • [9] Corneal Endothelial Cell Changes After Phacoemulsification Combined with Excisional Goniotomy with the Kahook Dual Blade or iStent: A Prospective Fellow-Eye Comparison
    Dorairaj, Syril
    Balasubramani, Goundappa K.
    [J]. CLINICAL OPHTHALMOLOGY, 2020, 14 : 4047 - 4053
  • [10] The DISCOVER Study 3-Year Results Feasibility and Usefulness of Microscope-Integrated Intraoperative OCT during Ophthalmic Surgery
    Ehlers, Justis P.
    Modi, Yasha S.
    Pecen, Paula E.
    Goshe, Jeff
    Dupps, William J.
    Rachitskaya, Aleksandra
    Sharma, Sumit
    Yuan, Alex
    Singh, Rishi
    Kaiser, Peter K.
    Reese, Jamie L.
    Calabrise, Carmen
    Watts, Allison
    Srivastava, Sunil K.
    [J]. OPHTHALMOLOGY, 2018, 125 (07) : 1014 - 1027