Validation of oscillometric ratio and maximum gradient methods for non-invasive blood pressure measurement with intra-arterial blood pressure measurements as reference

被引:0
|
作者
Celler, Branko G. [1 ]
Yong, Andy [2 ,3 ]
Rubenis, Imants [2 ]
Butlin, Mark [3 ]
Argha, Ahmadreza [4 ]
Rehan, Rajan [2 ]
Avolio, Alberto [3 ]
机构
[1] Univ New South Wales, Biomed Syst Res Lab, Kensington, Australia
[2] Univ Sydney, Concord Repatriat Hosp, Cardiol, Camperdown, Australia
[3] Macquarie Univ, Fac Med Hlth & Human Sci, Macquarie Med Sch, Sydney, NSW, Australia
[4] Univ New South Wales, Grad Sch Biomed Engn, Sydney, NSW, Australia
关键词
auscultatory methods; blood pressure; Korotkoff sounds; linear models; non-invasive blood pressure measurement; sphygmomanometry; SBP and DBP estimation; ALGORITHM; HYPERTENSION; PULSE;
D O I
10.1097/HJH.0000000000003698
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Most non-invasive blood pressure (BP) measurements are carried out using instruments which implement either the Ratio or the Maximum Gradient oscillometric method, mostly during cuff deflation, but more rarely during cuff inflation. Yet, there is little published literature on the relative advantages and accuracy of these two methods. In this study of 40 lightly sedated individuals aged 64.1 +/- 9.6 years, we evaluate and compare the performance of the oscillometric ratio (K) and gradient (Grad) methods for the non-invasive estimation of mean pressure, SBP and DBP with reference to invasive intra-arterial values. There was no significant difference between intra-arterial estimates of mean pressure made via Korotkoff sounds (MP-OWE) or the gradient method (MP-Grad). However, 17.7% of MP-OWE and 15% of MP-Grad were in error by more than 10 mmHg. SBP-K and SBP-Grad underestimated SBP by 14 and 18 mmHg, whilst accurately estimating DBP with mean errors of 0.4 +/- 5.0 and 1.7 +/- 6.1 mmHg, respectively. Relative to the reference standard SBP-K, SBP-Grad and DBP-Grad were estimated with a mean error of -4.5 +/- 6.6 and 1.4 +/- 5.6 mmHg, respectively, noting that using the full range of recommended ratios introduces errors of 12 and 7 mmHg in SBP and DBP, respectively. We also show that it is possible to find ratios which minimize the root mean square error (RMSE) and the mean error for any particular individual cohort. We developed linear models for estimating SBP and SBP-K from a range of demographic and non-invasive OWE variables with resulting mean errors of 0.15 +/- 5.6 and 0.3 +/- 5.7 mmHg, acceptable according to the Universal standard.
引用
收藏
页码:1075 / 1085
页数:11
相关论文
共 50 条
  • [21] Morphological Changes of Pressure Pulses in Oscillometric Non-Invasive Blood Pressure Measurements
    Avbelj, V.
    2014 37TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2014, : 245 - 248
  • [22] Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement
    Harju, Jarkko
    Vehkaoja, Antti
    Kumpulainen, Pekka
    Campadello, Stefano
    Lindroos, Ville
    Yli-Hankala, Arvi
    Oksala, Niku
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (01) : 13 - 22
  • [23] Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement
    Jarkko Harju
    Antti Vehkaoja
    Pekka Kumpulainen
    Stefano Campadello
    Ville Lindroos
    Arvi Yli-Hankala
    Niku Oksala
    Journal of Clinical Monitoring and Computing, 2018, 32 : 13 - 22
  • [24] INTRA-ARTERIAL BLOOD-PRESSURE MEASUREMENTS
    ZSIGMOND, EK
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1981, 245 (07): : 703 - 703
  • [25] Evaluation of the oscillometric technique for intermittent non-invasive arterial blood pressure measurement in the anaesthetized pig
    Ypsilantis, P.
    Didilis, V.
    Simopoulos, C.
    LABORATORY ANIMALS, 2013, 47 (02) : 94 - 99
  • [26] Compared values of the measurement of average pressure by intra-arterial and oscillometric methods
    Vaquez, H
    Gley, P
    Mouquin, M
    COMPTES RENDUS DES SEANCES DE LA SOCIETE DE BIOLOGIE ET DE SES FILIALES, 1933, 114 : 1305 - 1307
  • [27] Mathematical modelling of non-invasive oscillometric finger mean blood pressure measurement by maximum oscillation criterion
    R. Raamat
    J. Talts
    K. Jagomägi
    E. Länsimies
    Medical & Biological Engineering & Computing, 1999, 37 : 784 - 788
  • [28] Mathematical modelling of non-invasive oscillometric finger mean blood pressure measurement by maximum oscillation criterion
    Raamat, R
    Talts, J
    Jagomägi, K
    Länsimies, E
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (06) : 784 - 788
  • [29] Mathematical modelling of non-invasive oscillometric finger mean blood pressure measurement by maximum oscillation criterion
    Institute of Physiology, University of Tartu, Tartu, Estonia
    不详
    Med. Biol. Eng. Comput., 6 (784-788):
  • [30] OSCILLOMETRIC MEASUREMENT OF ARTERIAL BLOOD PRESSURE
    BENSON, H
    HERD, JA
    CIRCULATION, 1969, 40 (4S3) : II43 - &