Automatic Determination of Endothelial Cell Density From Donor Cornea Endothelial Cell Images

被引:1
|
作者
Benetz, Beth Ann M. [1 ,2 ]
Shivade, Ved S. [3 ]
Joseph, Naomi M. [3 ]
Romig, Nathan J. [3 ]
McCormick, John C. [3 ]
Chen, Jiawei [3 ]
Titus, Michael S. [4 ]
Sawant, Onkar B. [4 ,5 ]
Clover, Jameson M. [6 ]
Yoganathan, Nathan [6 ]
Menegay, Harry J. [1 ,2 ]
O'Brien, Robert C. [7 ]
Wilson, David L. [3 ]
Lass, Jonathan H. [1 ,2 ]
机构
[1] Case Western Reserve Univ, Dept Ophthalmol & Visual Sci, Cleveland, OH USA
[2] Univ Hosp Eye Inst, Cornea Image Anal Reading Ctr, Cleveland, OH USA
[3] Case Western Reserve Univ, Dept Biomed Engn, 340 Wickendon Bldg,10900 Euclid Ave, Cleveland, OH 44106 USA
[4] Eversight, Ann Arbor, MI USA
[5] Eversight, Ctr Vis & Eye Banking Res, Cleveland, OH USA
[6] VisionGift, Portland, OR USA
[7] Univ Miami, Bascom Palmer Eye Inst, Miami, FL USA
来源
基金
美国国家卫生研究院;
关键词
eye banking; deep learning; endothelial cells; SPECULAR-MICROSCOPY; DIABETIC-RETINOPATHY; QUANTITATIVE-ANALYSIS; AGE; AGREEMENT; SP-2000P; SYSTEM;
D O I
10.1167/tvst.13.8.40
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine endothelial cell density (ECD) from real-world donor cornea endothelial cell (EC) images using a self-supervised deep learning segmentation model. Methods: Two eye banks (Eversight, VisionGift) provided 15,138 single, unique EC images from 8169 donors along with their demographics, tissue characteristics, and ECD. This dataset was utilized for self-supervised training and deep learning inference. The Cornea Image Analysis Reading Center (CIARC) provided a second dataset of 174 donor EC images based on image and tissue quality. These images were used to train a supervised deep learning cell border segmentation model. Evaluation between manual and automated determination of ECD was restricted to the 1939 test EC images with at least 100 cells counted by both methods. Results: The ECD measurements from both methods were in excellent agreement with rc c of 0.77 (95% confidence interval [CI], 0.75-0.79; P < 0.001) and bias of 123 cells/mm2 2 (95% CI, 114-131; P < 0.001); 81% of the automated ECD values were within 10% of the manual ECD values. When the analysis was further restricted to the cropped image, the rc c was 0.88 (95% CI, 0.87-0.89; P < 0.001), bias was 46 cells/mm2 2 (95% CI, 39-53; P < 0.001), and 93% of the automated ECD values were within 10% of the manual ECD values. Conclusions: Deep learning analysis provides accurate ECDs of donor images, potentially reducing analysis time and training requirements. Translational Relevance: The approach of this study, a robust methodology for automatically evaluating donor cornea EC images, could expand the quantitative determination of endothelial health beyond ECD.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Specular microscopy ancillary study methods for donor endothelial cell density determination of cornea donor study images
    Benetz, BA
    Gal, RL
    Ruedy, KJ
    Rice, C
    Beck, RW
    Kalajian, AD
    Lass, JH
    CURRENT EYE RESEARCH, 2006, 31 (04) : 319 - 327
  • [2] Comparison of Endothelial Cell Density of Organ Cultured Corneas With Cornea Donor Study
    Campolmi, Nelly
    He, Zhiguo
    Acquart, Sophie
    Trone, Marie-Caroline
    Bernard, Aurelien
    Gauthier, Anne-Sophie
    Garraud, Olivier
    Forest, Fabien
    Peoc'h, Michel
    Gain, Philippe
    Thuret, Gilles
    CORNEA, 2014, 33 (06) : 597 - 603
  • [3] Image quality and accuracy of eye bank measurement of donor cornea endothelial cell density in The Cornea Donor Study
    Lass, JH
    Beck, RW
    Edwards, SR
    Gal, RL
    Ruedy, KJ
    Mannis, MJ
    Holland, EJ
    Rice, CL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U635 - U635
  • [4] A new system for the automatic estimation of endothelial cell density in donor corneas
    Ruggeri, A
    Grisan, E
    Jaroszewski, J
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (03) : 306 - 311
  • [5] Evaluation of repeatability for the automatic estimation of endothelial cell density in donor corneas
    Ruggeri, Alfredo
    Grisan, Enrico
    Schroeter, Jan
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (09) : 1213 - 1215
  • [6] Donor cell density and endothelial keratoplasty
    Stoeger, Christopher
    Terry, Mark A.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (02) : 292 - 293
  • [7] ENDOTHELIAL CELL-DENSITY IN DONOR CORNEAS
    SPERLING, S
    ACTA OPHTHALMOLOGICA, 1980, 58 (02): : 278 - 282
  • [8] COMPARISON OF DONOR CORNEA ENDOTHELIAL-CELL DENSITY BETWEEN CAUCASIAN AND BLACK-AMERICANS
    BAREZ, S
    POTARAZU, SV
    SLACK, JW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 925 - 925
  • [9] Endothelial cell density in donor corneas: A comparison of automatic software programs with manual counting
    Hirneiss, C
    Neubauer, AS
    Hartmann, K
    Welge-Luessen, U
    Kampik, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U521 - U521
  • [10] Endothelial cell density in donor corneas -: A comparison of automatic software programs with manual counting
    Hirneiss, Christoph
    Schumann, Ricarda G.
    Grueterich, Martin
    Welge-Luessen, Ulrich C.
    Kampik, Anselm
    Neubauer, Aljoscha S.
    CORNEA, 2007, 26 (01) : 80 - 83