A Novel Technique for Restricted Kinematic Alignment Total Knee Arthroplasty Without Computer-Assisted Devices

被引:0
作者
Sakakibara, Yuzuru [1 ,2 ]
Yasutani, Yusuke [1 ]
Oyama, Akimitsu [1 ]
Teramoto, Atsushi [2 ]
机构
[1] Muroran City Gen Hosp, Orthoped Surg, Muroran, Japan
[2] Sapporo Med Univ, Sch Med, Orthoped Surg, Sapporo, Japan
关键词
computer-assisted surgery; osteoarthritis of the knee; restricted kinematic alignment; kinematic alignment; total knee arthroplasty; MECHANICAL ALIGNMENT; TIBIAL ALIGNMENT; REPLACEMENT; MIGRATION; VARUS;
D O I
10.7759/cureus.67233
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Kinematic-alignment total knee arthroplasty (KA-TKA) aims to restore natural limb alignment and joint line obliquity, thereby improving patient satisfaction. Restricted KA-TKA (rKA-TKA) addresses abnormal knee anatomies and seeks to replicate natural anatomical structures within safe alignment boundaries. This study introduces a novel device and technique that enables rKA-TKA without computer-assisted surgery (CAS). The new device allows for precise cartilage thickness measurement and adjustment of osteotomy angles, facilitating accurate alignment. A heel-lift technique for tibial osteotomy is presented, offering a reproducible method for determining the osteotomy volume and angle. These innovations make KA and rKA-TKA feasible in any surgical setting, avoiding the high costs and limited availability associated with CAS.
引用
收藏
页数:11
相关论文
共 26 条
[1]   The Impact of Mechanical and Restricted Kinematic Alignment on Knee Anatomy in Total Knee Arthroplasty [J].
Almaawi, Abdulaziz M. ;
Hutt, Jonathan R. B. ;
Masse, Vincent ;
Lavigne, Martin ;
Vendittoli, Pascal-Andre .
JOURNAL OF ARTHROPLASTY, 2017, 32 (07) :2133-2140
[2]   Patient Satisfaction after Total Knee Arthroplasty Who is Satisfied and Who is Not? [J].
Bourne, Robert B. ;
Chesworth, Bert M. ;
Davis, Aileen M. ;
Mahomed, Nizar N. ;
Charron, Kory D. J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) :57-63
[3]  
Brown JHM, 2020, International Journal of Orthopaedics, V7, P1283, DOI [10.17554/j.issn.2311-5106.2020.07.345, 10.17554/ijo.v7i3.2767, 10.17554/j.issn.2311-5106.2020.07.345, DOI 10.17554/J.ISSN.2311-5106.2020.07.345]
[4]   Joint perception after hip or knee replacement surgery [J].
Collins, M. ;
Lavigne, M. ;
Girard, J. ;
Vendittoli, P. -A. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (03) :275-280
[5]   Arthroplasty Surgeons Differ in Their Intraoperative Soft Tissue Assessments: A Study in Human Cadavers to Quantify Surgical Decision-making in TKA [J].
Elmasry, Shady S. ;
Sculco, Peter K. ;
Kahlenberg, Cynthia A. ;
Mayman, David J. ;
Cross, Michael B. ;
Pearle, Andrew D. ;
Wright, Timothy M. ;
Westrich, Geoffrey H. ;
Imhauser, Carl W. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2022, 480 (08) :1604-1615
[6]   How Frequently Do Four Methods for Mechanically Aligning a Total Knee Arthroplasty Cause Collateral Ligament Imbalance and Change Alignment from Normal in White Patients? AAOS Exhibit Selection [J].
Gu, Yu ;
Roth, Joshua D. ;
Howell, Stephen M. ;
Hull, Maury L. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (12) :e101(1)
[7]   Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients [J].
Howell, Stephen M. ;
Kuznik, Kyle ;
Hull, Maury L. ;
Siston, Robert A. .
ORTHOPEDICS, 2008, 31 (09) :857-863
[8]   Calipered Kinematically Aligned Total Knee Arthroplasty: An Accurate Technique That Improves Patient Outcomes and Implant Survival [J].
Howell, Stephen M. .
ORTHOPEDICS, 2019, 42 (03) :126-+
[9]   Implant Survival and Function Ten Years After Kinematically Aligned Total Knee Arthroplasty [J].
Howell, Stephen M. ;
Shelton, Trevor J. ;
Hull, Maury L. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (12) :3678-3684
[10]   Assessment of the Radii of the Medial and Lateral Femoral Condyles in Varus and Valgus Knees with Osteoarthritis [J].
Howell, Stephen M. ;
Howell, Stacey J. ;
Hull, Maury L. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (01) :98-104