Fully Integrated Miniaturized Wireless Power Transfer Rectenna for Medical Applications Tested inside Biological Tissues

被引:5
作者
Fernandez-Munoz, Miguel [1 ]
Missous, Mohamed [2 ]
Sadeghi, Mohammadreza [3 ]
Lopez-Espi, Pablo Luis [4 ]
Sanchez-Montero, Rocio [4 ]
Martinez-Rojas, Juan Antonio [4 ]
Diez-Jimenez, Efren [1 ]
机构
[1] Univ Alcala, Mech Engn Area, Alcala De Henares 28801, Spain
[2] Univ Manchester, Dept Elect & Elect Engn, Manchester M13 9PL, England
[3] Adv Hall Sensors Ltd, Res & Dev Dept, Manchester M17 1RW, England
[4] Univ Alcala, Radiat & Sensing Grp, E-28801 Alcala De Henares, Spain
关键词
rectenna; wireless power transmission (WPT); medical implant; microdevice; BAND IMPLANTABLE ANTENNA; SYSTEM; BODY; FREQUENCY; DESIGN;
D O I
10.3390/electronics13163159
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This work presents the results of the characterization of two 1 x 5 mm2 miniaturized rectennas developed for medical applications. They have been designed for relatively high voltage and high-power applications, given the size of the rectennas. Both rectennas were tested in open-air conditions and surrounded by pork fat and muscle tissues, whose properties are similar to those of the human body. The resonant frequencies of the rectennas were found, and the incident electric field on the rectennas tests was increased. The first chip showed a maximum output voltage of 5.29 V and a maximum output power of 0.056 mW, at 1.446 GHz, under an incident field on the rectenna of 340 V/m, and the second chip, 4.62 V and 4.27 mW, at 1.175 GHz, under 535 V/m. The second rectenna can provide an output power greater than 5 mW. The rectennas presented in this article are beyond the state of the art, as they can deliver about three times more power and voltage than those of similar dimensions reported in the literature. Based on the test results, the efficiency of the rectennas was analyzed at different locations of the human body, considering different thicknesses of tissues with high and low water content. Finally, potential applications are described in which the rectennas could power implantable medical devices or microsurgery tools, for example, pulmonary artery pressure monitors.
引用
收藏
页数:13
相关论文
共 51 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]   Power Conversion Using Analytical Model of Cockcroft-Walton Voltage Multiplier Rectenna [J].
Ali, Esraa Mousa ;
Yahaya, Nor Zaihar ;
Saraereh, Omar Aqeel ;
Al Assaf, Anwar Hamdan ;
Alqasem, Bilal Hasan ;
Iqbal, Shahid ;
Ibrahim, Oladimeji ;
Patel, Amit, V .
ELECTRONICS, 2021, 10 (08)
[3]  
[Anonymous], 1989, Nota tcnica Prevencin del Inst. Nac. Segur. e Hig
[4]  
Bailey W.H., 2019, Synopsis of IEEE Std C95.1TM-2019 IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, VVolume 7
[5]  
Balanis C.A., 1997, Antenna theory: Analysis And Design, V2nd ed.
[6]   Efficient Wireless Power Transfer System With a Miniaturized Quad-Band Implantable Antenna for Deep-Body Multitasking Implants [J].
Basir, Abdul ;
Yoo, Hyoungsuk .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2020, 68 (05) :1943-1953
[7]   Complete system for wireless powering and remote control of electrostatic actuators by inductive coupling [J].
Basset, Philippe ;
Kaiser, Andreas ;
Legrand, Bernard ;
Collard, Dominique ;
Buchaillot, Lionel .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2007, 12 (01) :23-31
[8]   Far-Field RF Powering of Implantable Devices: Safety Considerations [J].
Bercich, Rebecca A. ;
Duffy, Daniel R. ;
Irazoqui, Pedro P. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (08) :2107-2112
[9]   Wireless Power Transmission: R&D Activities Within Europe [J].
Carvalho, Nuno Borges ;
Georgiadis, Apostolos ;
Costanzo, Alessandra ;
Rogier, Hendrik ;
Collado, Ana ;
Angel Garcia, Jose ;
Lucyszyn, Stepan ;
Mezzanotte, Paolo ;
Kracek, Jan ;
Masotti, Diego ;
Soares Boaventura, Alirio J. ;
Ruiz Lavin, Maria de las Nieves ;
Pinuela, Manuel ;
Yates, David C. ;
Mitcheson, Paul D. ;
Mazanek, Milos ;
Pankrac, Vitezslav .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2014, 62 (04) :1031-1045
[10]  