Clinical boundary conditions for propagation-based X-ray phase contrast imaging: from bio-sample models targeting to clinical applications

被引:1
作者
Gobo, M. S. S. [1 ]
Balbin, D. R. [1 ]
Honnicke, M. G. [2 ]
Poletti, M. E. [1 ]
机构
[1] Univ Sao Paulo, Dept Fis, Fac Filosofia Ciencias & Letras Ribeirao Preto, Sao Paulo, Brazil
[2] Univ Fed Integracao Latino Amer, Inst Latino Amer Ciencias Vida & Nat, Foz Do Iguacu, Brazil
关键词
Phase contrast imaging; propagation-based; edge-enhancement; optimization; digital dental detector; clinical application; EDGE-ENHANCEMENT; MAMMOGRAPHY; QUANTIFICATION; TOMOGRAPHY; RESOLUTION; RETRIEVAL; IMAGES; NOISE;
D O I
10.3233/XST-230425
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Typical propagation-based X-ray phase contrast imaging (PB-PCI) experiments using polyenergetic sources are tested in very ideal conditions: low-energy spectrum (mainly characteristic X-rays), small thickness and homogeneous materials considered weakly absorbing objects, large object-to-detector distance, long exposure times and non-clinical OBJECTIVE: Explore PB-PCI features using boundary conditions imposed by a low power polychromatic X-ray source (X-ray spectrum without characteristic X-rays), thick and heterogenous materials and a small area imaging detector with high low-detection radiation threshold, elements commonly found in a clinical scenario. METHODS: A PB-PCI setup implemented using a microfocus X-ray source and a dental imaging detector was characterized in terms of different spectra and geometric parameters on the acquired images. Test phantoms containing fibers and homogeneous materials with close attenuation characteristics and animal bone and mixed soft tissues (bio-sample models) were analyzed. Contrast to Noise Ratio (CNR), system spatial resolution and Kerma values were obtained for all images. RESULTS: Phase contrast images showed CNR up to 15% higher than conventional contact images. Moreover, it is better seen when large magnifications (>3) and object-to-detector distances (>13 cm) were used. The influence of the spectrum was not appreciable due to the low efficiency of the detector (thin scintillator screen) at high energies. CONCLUSIONS: Despite the clinical boundary condition used in this work, regarding the X-ray spectrum, thick samples, and detection system, it was possible to acquire phase contrast images of biological samples.
引用
收藏
页码:1163 / 1175
页数:13
相关论文
共 66 条
[1]   Spatial frequency domain analysis of a commercially available digital dental detector [J].
Anastasiou, A. ;
Papastamati, F. ;
Bakas, A. ;
Michail, C. ;
Koukou, V. ;
Martini, N. ;
Ninos, K. ;
Lavdas, E. ;
Valais, I. ;
Fountos, G. ;
Kandarakis, I. ;
Kalyvas, N. .
MEASUREMENT, 2020, 151
[2]   Low-dose phase contrast x-ray medical imaging [J].
Arfelli, F ;
Assante, M ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :2845-2852
[3]   Multiple image x-radiography for functional lung imaging [J].
Aulakh, G. K. ;
Mann, A. ;
Belev, G. ;
Wiebe, S. ;
Kuebler, W. M. ;
Singh, B. ;
Chapman, D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (01)
[4]   A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging [J].
Bennett, Eric E. ;
Kopace, Rael ;
Stein, Ashley F. ;
Wen, Han .
MEDICAL PHYSICS, 2010, 37 (11) :6047-6054
[5]   Optimization of propagation-based phase-contrast imaging at a laboratory setup [J].
Bidola, Pidassa M. ;
Zanette, Irene ;
Achterhold, Klaus ;
Holzner, Christian ;
Pfeiffer, Franz .
OPTICS EXPRESS, 2015, 23 (23) :30000-30013
[6]   X-ray phase-contrast imaging: from pre-clinical applications towards clinics [J].
Bravin, Alberto ;
Coan, Paola ;
Suortti, Pekka .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (01) :R1-R35
[7]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[8]   PHASE-CONTRAST IMAGING OF WEAKLY ABSORBING MATERIALS USING HARD X-RAYS [J].
DAVIS, TJ ;
GAO, D ;
GUREYEV, TE ;
STEVENSON, AW ;
WILKINS, SW .
NATURE, 1995, 373 (6515) :595-598
[9]   A single-image retrieval method for edge illumination X-ray phase-contrast imaging: Application and noise analysis [J].
Diemoz, Paul C. ;
Vittoria, Fabio A. ;
Hagen, Charlotte K. ;
Endrizzi, Marco ;
Coan, Paola ;
Bravin, Alberto ;
Wagner, Ulrich H. ;
Rau, Christoph ;
Robinson, Ian K. ;
Olivo, Alessandro .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12) :1759-1764
[10]   A method for high-energy, low-dose mammography using edge illumination x-ray phase-contrast imaging [J].
Diemoz, Paul C. ;
Bravin, Alberto ;
Sztrokay-Gaul, Aniko ;
Ruat, Marie ;
Grandl, Susanne ;
Mayr, Doris ;
Auweter, Sigrid ;
Mittone, Alberto ;
Brun, Emmanuel ;
Ponchut, Cyril ;
Reiser, Maximilian F. ;
Coan, Paola ;
Olivo, Alessandro .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (24) :8750-8761