Early clinical outcome with lens position adjustment following implantable collamer lens surgery

被引:0
作者
Zhang, Qian [1 ,2 ]
Zhao, Bo [2 ]
Yang, Xue-Fei [2 ]
Liu, Zhang-Lin [1 ]
Huang, Yue [1 ]
机构
[1] Tianjin Med Univ Eye Hosp, Eye Inst, Natl Clin Res Ctr Ocular Dis, Refract Surg Dept,Tianjin Branch,Tianjin Key Lab R, Tianjin 300384, Peoples R China
[2] Tianjin Univ, Aier Eye Hosp, Refract Surg Dept, Tianjin 300190, Peoples R China
关键词
implantable collamer lens; myopia; lens positional adjustment; arch height; intraocular pressure; PHAKIC INTRAOCULAR-LENS; REFRACTIVE SURGERY; MYOPIA; VAULT; EYES; HYPEROPIA; EFFICACY; SAFETY; SMILE; V4C;
D O I
10.18240/ijo.2024.09.12
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To observe early clinical outcome with lens position adjustment following the implantable collamer lens (ICL) surgery. METHODS: Sixty patients were selected for this retrospective study. One eye from each patient received Toric ICL for astigmatism correction, and the other received non-astigmatic ICL surgery using horizontal position. Patients with higher postoperative arch height were selected, and their non-astigmatic eye clinical outcome were observed after ICL surgery at 1wk, 1, and 3mo. The clinical measurements included uncorrected visual acuity (UCVA), intraocular pressure (IOP), refractive state, corneal endothelium cell count, and arch height. Three months later, the ICL in each patient's non-astigmatic eye was adjusted to the vertical from the horizontal position. The results were compared before and 1wk, 1, and 3mo after adjustment. RESULTS: UCVA and IOP were significantly reduced 1wk after position adjustment compared to 1wk after ICL implantation (P<0.05). The patients demonstrated significantly reduced arch height and corneal endothelium cell count 1wk, 1, and 3mo after adjusting position compared to 1wk, 1, and 3mo after ICL implantation (P<0.05). However, there was no significant difference in refraction between 1wk, 1, and 3mo after ICL implantation and position adjustment (P>0.05). CONCLUSION: Early positioning adjustment postphakic ICL implantation can benefit patients with adjusted arch height or higher IOP. Despite the good clinical effects, the doctors should pay attention to the potential for adverse effects on UCVA and corneal endothelium cells following early position adjustment after posterior chamber phakic ICL implantation.
引用
收藏
页码:1654 / 1658
页数:5
相关论文
共 25 条
[1]   Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Fernandez-Vega, Luis ;
Almanzar, Dagoberto ;
Perez-Vives, Cari ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (04) :800-805
[2]   Long-term evaluation of the central vault after phakic CollamerA® lens (ICL) implantation using OCT [J].
Alfonso, Jose F. ;
Fernandez-Vega, L. ;
Lisa, C. ;
Fernandes, P. ;
Gonzalez-Meijome, J. ;
Montes-Mico, R. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (12) :1807-1812
[3]   Refractive surgery beyond 2020 [J].
Ang, Marcus ;
Gatinel, Damien ;
Reinstein, Dan Z. ;
Mertens, Erik ;
Alio del Barrio, Jorge L. ;
Alio, Jorge L. .
EYE, 2021, 35 (02) :362-382
[4]   Safety and efficacy of toric implantable collamer lens V4c model - A retrospective South Indian study [J].
Chaitanya, S. Ravi ;
Anitha, Venugopal ;
Ravindran, Meenakshi ;
Ghorpade, Aditya ;
Rengappa, Ramakrishnan ;
Uduman, Mahammed Sithiq .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (12) :3006-3011
[5]   Trifocal intraocular lens implantation in eyes with previous corneal refractive surgery for myopia and hyperopia [J].
Cobo-Soriano, Rosario ;
Ortega-Usobiaga, Julio ;
Rodriguez-Gutierrez, Beatriz ;
Tejerina, Victor ;
Llovet, Fernando ;
Casco, Bruno ;
Baviera, Julio .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (10) :1265-1272
[6]   A new formula based on new parameters for predicting postoperative vault after posterior chamber intraocular lens implantation: a retrospective study [J].
Cui, Wei ;
Wu, Xiaoming ;
Ren, Qi ;
Liu, Kun ;
Kong, Fanqin ;
Wu, Jie .
QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (09) :5502-5510
[7]   Visual acuity, refractive error, and regression outcomes in 169 children with high myopia who were implanted with Ophtec-Artisan or Visian phakic IOLs [J].
Faron, Nicholas ;
Hoekel, James ;
Tychsen, Lawrence .
JOURNAL OF AAPOS, 2021, 25 (01) :27.e1-27.e8
[8]   Incidence of implantable Collamer lens-induced cataract [J].
Gimbel, Howard V. ;
LeClair, Bronson M. ;
Jabo, Brice ;
Marzouk, Hala .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2018, 53 (05) :518-522
[9]   Comparison of corneal endothelial cell density and morphology after posterior chamber phakic intraocular lens implantation with and without a central hole [J].
Goukon, Hiroyasu ;
Kamiya, Kazutaka ;
Shimizu, Kimiya ;
Igarashi, Akihito .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (11) :1461-1465
[10]   Factors Affecting Vaulting After Implantable Collamer Lens Implantation [J].
Kamiya, Kazutaka ;
Shimizu, Kimiya ;
Komatsu, Mari .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (03) :259-264