Influence of Computer-Aided Detection False-Positives on Reader Performance and Diagnostic Confidence for CT Colonography

被引:19
|
作者
Taylor, Stuart A. [1 ]
Brittenden, John [2 ]
Lenton, James [3 ]
Lambie, Hannah [3 ]
Goldstone, Anthony [3 ]
Wylie, Peter N. [4 ]
Tolan, Damian [3 ]
Burling, David [4 ]
Honeyfield, Leslie [5 ]
Bassett, Paul [6 ]
Halligan, Steve [1 ]
机构
[1] Univ Coll London Hosp, Dept Specialist Imaging, London NW1 2BU, England
[2] Pinderfields Gen Hosp, Dept Clin Radiol, Wakefield, W Yorkshire, England
[3] Leeds Teaching Hosp NHS Trust, Leeds Gen Infirm, Dept Clin Radiol, Leeds, W Yorkshire, England
[4] St Marks Hosp, Dept Intestinal Imaging, Harrow, Middx, England
[5] Medicsight PLC, London, England
[6] Stat Consultancy, Ruislip, Middx, England
关键词
colorectal cancer; computer-aided detection; CT colonography; screening; TOMOGRAPHIC VIRTUAL COLONOSCOPY; POLYP DETECTION; ASSISTED DETECTION; 2ND READER; REDUCTION; CAD; SOFTWARE;
D O I
10.2214/AJR.08.1625
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to investigate whether an increasing number of computer-aided detection (CAD) false-positives decreases reader sensitivity, specificity, and confidence for nonexpert readers of CT colonography (CTC). MATERIALS AND METHODS. Fifty CTC data sets (29 men; mean age, 65 years), 25 of which contained 35 polyps >= 5 mm, were selected in which CAD had 100% polyp sensitivity at two sphericity settings (0 and 75) but differed in the number of false-positives. The data sets were read by five readers twice: once at each sphericity setting. Sensitivity, specificity, report time, and confidence before and after second-read CAD were compared using the paired exact and Student's t test, respectively. Receiver operating characteristic (ROC) curves were generated using reader confidence (1-100) in correct case classification (normal or abnormal). RESULTS. CAD generated a mean of 42 (range, 3-118) and 15 (range, 1-36) false-positives at a sphericity of 0 and 75, respectively. CAD at both settings increased per-patient sensitivity from 82% to 87% (p = 0.03) and per-polyp sensitivity by 8% and 10% for a sphericity of 0 and 75, respectively (p < 0.001). Specificity decreased from 84% to 79% (sphericity 0 and 75, p = 0.03 and 0.07). There was no difference in sensitivity, specificity, or reader confidence between sphericity settings (p = 1.0, 1.0, 0.11, respectively). The area under the ROC curve was 0.78 (95% CI, 0.70-0.86) and 0.77 (0.68-0.85) for a sphericity of 0 and 75, respectively. CAD added a median of 4.4 minutes (interquartile range [IQR], 2.7-6.5 minutes) and 2.2 minutes (IQR, 1.2-4.0 minutes) for a sphericity of 0 and 75, respectively (p < 0.001). CONCLUSION. CAD has the potential to increase the sensitivity of readers inexperienced with CTC, although specificity may be reduced. An increased number of CAD-generated false-positives does not negate any beneficial effect but does reduce efficiency.
引用
收藏
页码:1682 / 1689
页数:8
相关论文
共 50 条
  • [1] CT Colonography with Computer-aided Detection: Recognizing the Causes of False-Positive Reader Results
    Trilisky, Igor
    Dachman, Abraham H.
    Wroblewski, Kristen
    Vannier, Michael W.
    Horne, John M.
    RADIOGRAPHICS, 2014, 34 (07) : 1885 - 1905
  • [2] CURRENT CONCEPTS IN COMPUTER-AIDED DETECTION FOR CT COLONOGRAPHY
    Summers, Ronald M.
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 269 - 272
  • [3] Comparative performance of a primary-reader and second-reader paradigm of computer-aided detection for CT colonography in a low-prevalence screening population
    Miyake, Mototaka
    Iinuma, Gen
    Taylor, Stuart A.
    Halligan, Steve
    Morimoto, Tsuyoshi
    Ichikawa, Tamaki
    Tomimatsu, Hideto
    Beddoe, Gareth
    Sugimura, Kazuro
    Arai, Yasuaki
    JAPANESE JOURNAL OF RADIOLOGY, 2013, 31 (05) : 310 - 319
  • [4] Computer-aided detection of polyps in CT colonography:: Evaluation of volumetric features in differentiating polyps from false positives
    Näppi, J
    Dachman, AH
    MacEneaney, PM
    Yoshida, H
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 635 - 640
  • [5] Increasing computer-aided detection specificity by projection features for CT colonography
    Zhu, Hongbin
    Liang, Zhengrong
    Pickhardt, Perry J.
    Barish, Matthew A.
    You, Jiangsheng
    Fan, Yi
    Lu, Hongbing
    Posniak, Erica J.
    Richards, Robert J.
    Cohen, Harris L.
    MEDICAL PHYSICS, 2010, 37 (04) : 1468 - 1481
  • [6] Projection-based features for reducing false positives in computer-aided detection of colonic polyps in CT colonography
    Zhu, Hongbin
    Barish, Matthew
    Pickhardt, Perry
    Fan, Yi
    Posniak, Erica
    Richards, Robert
    Liang, Zhengrong
    MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, 2010, 7624
  • [7] Computer-Aided Detection of Polyps in CT Colonography Using Logistic Regression
    van Ravesteijn, Vincent F.
    van Wijk, Cees
    Vos, Frans M.
    Truyen, Roel
    Peters, Joost F.
    Stoker, Jaap
    van Vliet, Lucas J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) : 120 - 131
  • [8] Computer-aided detection for CT colonography: update 2007
    Bielen, Didier
    Kiss, Gabriel
    ABDOMINAL IMAGING, 2007, 32 (05): : 571 - 581
  • [9] Computer-aided detection (CAD) as a second reader using perspective filet view at CT colonography: effect on performance of inexperienced readers
    Fisichella, V. A.
    Jaderling, F.
    Horvath, S.
    Stotzer, P. -O.
    Kilander, A.
    Bath, M.
    Hellstrom, M.
    CLINICAL RADIOLOGY, 2009, 64 (10) : 972 - 982
  • [10] Computer-Aided Detection for Computed Tomographic Colonography Screening A Prospective Comparison of a Double-Reading Paradigm With First-Reader Computer-Aided Detection Against Second-Reader Computer-Aided Detection
    Iussich, Gabriella
    Correale, Loredana
    Senore, Carlo
    Hassan, Cesare
    Segnan, Nereo
    Campanella, Delia
    Bert, Alberto
    Galatola, Giovanni
    Laudi, Cristiana
    Regge, Daniele
    INVESTIGATIVE RADIOLOGY, 2014, 49 (03) : 173 - 182