No differences in clinical and radiographic outcomes between standard versus high offset collared stems for primary total hip arthroplasty at five years follow-up

被引:0
作者
Jacquot, Laurent [1 ,2 ]
Machenaud, Alain [1 ]
Grew, Bethany [3 ]
Ramos-Pascual, Sonia [3 ]
Dubreuil, Sonia [3 ]
Saffarini, Mo [3 ]
Chouteau, Julien [1 ,2 ]
机构
[1] Artro Inst, 8 Rue Pont The, F-74940 Annecy Le Vieux, France
[2] Clin Argonay, Ctr Pericles, F-74370 Annecy, France
[3] ReSurg SA, Rue St Jean 22, CH-1260 Nyon, Switzerland
关键词
Total hip arthroplasty; THA; High offset stem; Collared stem; LONG;
D O I
10.1007/s00264-024-06264-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To compare clinical and radiographic outcomes of propensity-matched patients undergoing THA using standard versus high offset stems at five years. Methods The authors retrospectively reviewed a consecutive series of primary THAs performed between 01/09/2015-31/12/2017 using a fully-hydroxyapatite coated collared stem, with either a standard (n = 365) or high (n = 110) offset. Outcomes collected included: modified Harris Hip Score (mHHS), Oxford Hip Score (OHS), Forgotten Joint Score (FJS), and radiographic measurements including limb length discrepancy (LLD), stem subsidence, and stem radiolucencies. Results Propensity score matching resulted in 80 hips per group. Preoperatively there were no significant differences in patient demographics, surgical data and radiographic measurements, except the standard offset group had significantly smaller femoral (40.0 +/- 7.5 vs 48.4 +/- 6.2, p < 0.001), acetabular (92. +/- 6.3 vs 94.8 +/- 7.3, p = 0.011) and global (132.0 +/- 10.3 vs 143.2 +/- 8.2, p < 0.001) offsets compared to the high offset group. At a minimum five years follow-up, there were no significant differences in mHHS (93.2 +/- 11.0 vs 93.1 +/- 10.6, p = 0.553), OHS (45.1 +/- 4.1 vs 45.3 +/- 4.6, p = 0.623), and FJS (85.1 +/- 19.3 vs 82.7 +/- 23.0, p = 0.910). There were also no differences in radiographic measurements, including LLD (1.5 +/- 4.8 vs 1.1 +/- 3.5, p = 0.537), stem subsidence (0% vs 0%, p = 1.000), and stem radiolucencies (severe: 6% vs 1%, p = 0.152). Conclusion The present matched-cohort study found no significant differences between standard versus high offset straight fully-hydroxyapatite coated collared stems for primary THA in terms of clinical and radiographic outcomes at five years. These findings may suggest that uncemented collared high offset stems are not associated with an increased risk of radiolucencies and loosening compared to uncemented collared standard offset stems.
引用
收藏
页码:2525 / 2533
页数:9
相关论文
共 19 条
  • [1] Outcomes of total hip arthroplasty using collared versus collarless uncemented HA-coated stems: a meta-analysis
    Ait-Si-Selmi, Tarik
    Vidalain, Jean-Pierre
    Ramos-Pascual, Sonia
    Kuratle, Thomas
    Saffarini, Mo
    Dejour, Edouard
    Bonnin, Michel P.
    [J]. EFORT OPEN REVIEWS, 2024, 9 (04) : 264 - 275
  • [2] Restoring global offset and lower limb length with a 3 offset option double-tapered stem
    Biggi, Stefano
    Banci, Lorenzo
    Tedino, Riccardo
    Capuzzo, Andrea
    Cattaneo, Gabriele
    Tornago, Stefano
    Camera, Andrea
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [3] D'Ambrosio A, 2020, BONE JOINT RES, V9, P182, DOI [10.1302/2046-3758.94.BJR-2019-0149.82, 10.1302/2046-3758.94.BJR-2019-0149.R2]
  • [4] Total Hip Arthroplasty Improves the Quality-Adjusted Life Years in Patients Who Exceeded the Estimated Life Expectancy
    Dimitriou, Dimitris
    Antoniadis, Alexander
    Flury, Andreas
    Liebhauser, Martin
    Helmy, Naeder
    [J]. JOURNAL OF ARTHROPLASTY, 2018, 33 (11) : 3484 - 3489
  • [5] Evans JT, 2019, LANCET, V393, P647, DOI 10.1016/S0140-6736(18)31665-9
  • [6] Faveere A., 2023, ORTHOPAEDIC PROC, V105, P28, DOI DOI 10.1302/1358-992X.2023.2.028
  • [7] Clinical and radiological outcomes of an uncemented metaphyseal short stem at minimum 10 years of follow-up: a prospective observational study
    Grappiolo, Guido
    Gambaro, Francesco Manlio
    Spera, Marco
    Chiappetta, Katia
    Morenghi, Emanuela
    Loppini, Mattia
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (01) : 425 - 431
  • [8] Comparison of Tri-Lock Bone Preservation Stem and the Conventional Standard Corail Stem in Primary Total Hip Arthroplasty
    Guo, Jiang
    Tan, Jie
    Peng, Lei
    Song, Qian
    Kong, Hao-ran
    Wang, Peng
    Shen, Hui-yong
    [J]. ORTHOPAEDIC SURGERY, 2021, 13 (03) : 749 - 757
  • [9] Hellman EJ, 1999, CLIN ORTHOP RELAT R, P164
  • [10] A Prospective, Randomized Comparison of the Long-Term Clinical and Radiographic Results of an Ultra-Short vs a Conventional Length Cementless Anatomic Femoral Stem
    Kim, Young-Hoo
    Jang, Young-Soo
    Kim, Eun-Jung