Numerical analysis of the seismic performance of existing steel frames with rigid connection with truss-beam-segments

被引:0
作者
Meng, Bao [1 ,2 ]
Li, Hui [1 ]
Liang, Honghui [1 ]
Zhong, Weihui [1 ]
Wen, Junlong [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Peoples R China
[2] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian 710055, Peoples R China
基金
美国国家科学基金会;
关键词
Steel frame; segments; Seismic performance; Numerical analysis; Design method; MOMENT CONNECTIONS; LOAD BEHAVIOR; RETROFIT; DESIGN;
D O I
10.1016/j.soildyn.2024.108910
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Addressing the insufficient research on fully welded connection with truss-beam-segments (FWCT), this study conducts a comprehensive investigation into the seismic performance of FWCT and its associated steel frame. Primary parameters influencing the seismic performance of FWCT are examined through numerical analysis, and a design method for FWCT is provided. Subsequently, a time-history analysis of composite frames with FWCTs is proposed to investigate the effect of adding truss-beam-segments during rare earthquakes on the seismic performance of the structure as a whole, along with reinforcement recommendations. The study results show that the width of the truss-beam-segment (TS) should ideally be equal to the width of the beam flange, with a thickness equal to that of the beam flange. The net height should be less than or equal to 0.17 times the clear height of the steel beam. The horizontal angle of the external diagonal leg should be less than or equal to 40 degrees, and the length of the horizontal short leg should be greater than the plastic deformation region length at the beam root. The axial compression ratio for the column should be less than 0.7 to prevent local buckling of the column. As the thickness of the composite slab increases, the initial stiffness and load-bearing capacity of the positive moment region gradually increase, while those of the negative moment region remain relatively constant. Timehistory analysis indicates that the maximum story displacement and inter-story displacement of the composite frame with TSs are reduced by 4.7 %-5.3 % and 2.5 %-5.8 %, respectively, compared to the composite frame without TSs under seismic wave action. This implies an enhanced capacity of the composite frame with TSs to withstand lateral deformation. For a mid-to high-rise composite frame with n stories, the addition of TSs was recommended primarily for the first (n/2 + 1) floors where plastic regions occur, aiming for a more economically efficient retrofit design and enhanced seismic performance.
引用
收藏
页数:15
相关论文
共 30 条
[21]  
MOHURD, 2016, Code for design of composite structures
[22]  
MOHURD, 2010, Code for Seismic Design of Buildings (GB50011-2010)
[23]  
[聂建国 Nie Jianguo], 2013, [工程力学, Engineering Mechanics], V30, P59
[24]   Design and numerical analysis of a damage-controllable mechanical hinge beam-to-column connection [J].
Peng, Han ;
Ou, Jinping ;
Mahin, Stephen .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2020, 133
[25]   Design of steel MRF connections before and after 1994 Northridge earthquake [J].
Popov, EP ;
Yang, TS ;
Chang, SP .
ENGINEERING STRUCTURES, 1998, 20 (12) :1030-1038
[26]   Seismic retrofit of welded steel moment connections with highly composite floor slabs [J].
Sung-Yong, Kim ;
Cheol-Ho, Lee .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 139 :62-68
[27]   Seismic performance of steel moment frames considering the effects of column-base hysteretic behavior and gravity framing system [J].
Torres-Rodas, Pablo ;
Flores, Francisco ;
Pozo, Sebastian ;
Astudillo, Bryam X. .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 144 (144)
[28]  
Xu YL, 2018, Research on seismic performance and design method of weak axis connection joints of steel frame beams and columns with concrete floors
[29]  
Yang W, 2006, Research on the mechanical performance of seismic reinforcement of steel structure beam column rigid joint under load
[30]   Influence of corrosion on seismic performance of steel beam-to-column connections [J].
Zhang, Yuelin ;
Fang, Cheng ;
Wang, Wei ;
Wu, Lingfeng ;
Cao, Peng .
ENGINEERING STRUCTURES, 2024, 312