Numerical analysis of the seismic performance of existing steel frames with rigid connection with truss-beam-segments

被引:0
作者
Meng, Bao [1 ,2 ]
Li, Hui [1 ]
Liang, Honghui [1 ]
Zhong, Weihui [1 ]
Wen, Junlong [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Peoples R China
[2] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian 710055, Peoples R China
基金
美国国家科学基金会;
关键词
Steel frame; segments; Seismic performance; Numerical analysis; Design method; MOMENT CONNECTIONS; LOAD BEHAVIOR; RETROFIT; DESIGN;
D O I
10.1016/j.soildyn.2024.108910
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Addressing the insufficient research on fully welded connection with truss-beam-segments (FWCT), this study conducts a comprehensive investigation into the seismic performance of FWCT and its associated steel frame. Primary parameters influencing the seismic performance of FWCT are examined through numerical analysis, and a design method for FWCT is provided. Subsequently, a time-history analysis of composite frames with FWCTs is proposed to investigate the effect of adding truss-beam-segments during rare earthquakes on the seismic performance of the structure as a whole, along with reinforcement recommendations. The study results show that the width of the truss-beam-segment (TS) should ideally be equal to the width of the beam flange, with a thickness equal to that of the beam flange. The net height should be less than or equal to 0.17 times the clear height of the steel beam. The horizontal angle of the external diagonal leg should be less than or equal to 40 degrees, and the length of the horizontal short leg should be greater than the plastic deformation region length at the beam root. The axial compression ratio for the column should be less than 0.7 to prevent local buckling of the column. As the thickness of the composite slab increases, the initial stiffness and load-bearing capacity of the positive moment region gradually increase, while those of the negative moment region remain relatively constant. Timehistory analysis indicates that the maximum story displacement and inter-story displacement of the composite frame with TSs are reduced by 4.7 %-5.3 % and 2.5 %-5.8 %, respectively, compared to the composite frame without TSs under seismic wave action. This implies an enhanced capacity of the composite frame with TSs to withstand lateral deformation. For a mid-to high-rise composite frame with n stories, the addition of TSs was recommended primarily for the first (n/2 + 1) floors where plastic regions occur, aiming for a more economically efficient retrofit design and enhanced seismic performance.
引用
收藏
页数:15
相关论文
共 30 条
  • [11] Li L., 2014, Journal of Disaster Prevention and Reduction Engineering, V34, P224, DOI DOI 10.13409/J.CNKI.JDPME.2014.02.020
  • [12] Mahin SA, 1998, J Perform Constr Facil, V12, P172, DOI [10.1061/(ASCE)0887-3828(1998)12:4172, DOI 10.1061/(ASCE)0887-3828(1998)12:4172]
  • [13] Enhancing the Collapse Resistance of a Composite Subassembly with Fully Welded Joints Using Sliding Inner Cores
    Meng, Bao
    Li, Hui
    Liew, Jat-Yuen Richard
    Li, Shan
    Kong, De-Yang
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (08)
  • [14] Progressive collapse behaviour of composite substructure with large rectangular beam-web openings
    Meng, Bao
    Xiong, Yunpeng
    Zhong, Weihui
    Duan, Shichao
    Li, Hui
    [J]. ENGINEERING STRUCTURES, 2023, 295
  • [15] Improving seismic performance of fully welded connection based on truss beam segments
    Meng, Bao
    Du, Qiangqiang
    Li, Hui
    Li, Liangde
    Du, Yipeng
    Li, Fudong
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 211
  • [16] Tensile resistance and deformation of novel bending T-stub connections against progressive collapse
    Meng, Bao
    Du, Qiangqiang
    Zhong, Weihui
    Tan, Zheng
    You, Ke
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 201
  • [17] Ministry of Housing and Urban-Rural Development of the People's Republic of China (MOHURD), 2017, Standard for design of steel structures (GB 50017-2017)
  • [18] Ministry of Housing and Urban-Rural Development of the People's Republic of China (MOHURD), 2016, Code for design of composite structures (JGJ138-2016)
  • [19] Ministry of Housing and Urban-Rural Development of the People's Republic of China (MOHURD), 2010, Code for Seismic Design of Buildings (GB 50011-2010)
  • [20] Ministry of Housing and Urban-Rural Development of the People's Republic of China (MOHURD), 2008, Classification standard for seismic fortification of building engineering (GB50223-2008)