Portable Electrochemical Immunosensor Based on a Gold Microblobs-Optimized Screen-Printed Electrode for SARS-CoV-2 Diagnosis

被引:0
|
作者
Giacomet, Melissa M. [1 ]
Buzzetti, Paulo H. M. [2 ]
Junior, Oscar O. S. [3 ]
Martins, Alessandro F. [4 ]
Bonafe, Elton G. [1 ]
Monteiro, Johny P. [1 ]
机构
[1] Univ Tecnol Fed Parana UTFPR, Chem Dept, Lab Mat Macromol & Compositos LAMMAC, BR-86812460 Apucarana, PR, Brazil
[2] Univ Grenoble Alpes UGA, Dept Chim Mol DCM, F-38000 Grenoble, France
[3] Univ Estadual Maringa UEM, Chem Dept, BR-87020900 Maringa, PR, Brazil
[4] Pittsburg State Univ, Dept Chem, Pittsburg, KS 66762 USA
关键词
biosensor; COVID-19; gold structure; electrochemistry; portable device; sensing; BIOSENSOR;
D O I
10.3390/inorganics12090252
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The development of biosensors for determining the most diverse biomolecules is a constant focus of many research groups. There is a latent need to propose sensors that combine portability, simple measurements, and good analytical performance. Here, we propose an electrochemical immunosensor that is fully portable and energy-independent for diagnosing antibodies against SARS-CoV-2 (the virus that causes COVID-19). Initially, disposable screen-printed carbon electrodes (SPEs) were covered by gold microblobs (AuMBs), which were synthesized amperometrically from Au3+ ions. Then, the SPE-AuMBs were coated with cysteamine, which allowed the N-hydroxysuccinimide-activated SARS-CoV-2 antigen (spike protein) to be immobilized. The antigen-activated electrode was used to detect COVID-19 antibodies from current measurements obtained by differential pulse voltammetry. The AuMBs synthesis time was optimized, and the presence of gold structures improved the electrochemical responses of the SPE. It was possible to quantitatively determine antibodies in the concentration range of 0.25 to 10 mu g mL-1. This range includes concentrations found in biological fluids from patients at any stage of the disease. An analysis took approximately the same time as traditional rapid nasal tests (20 min) and costed less, considering all the steps necessary to prepare a disposable antigen-functionalized SPE.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] In situ detection of heavy metal ions in sewage with screen-printed electrode-based portable electrochemical sensors
    Bao, Qiwen
    Li, Gang
    Yang, Zhengchun
    Pan, Peng
    Liu, Jun
    Li, Ruirui
    Wei, Jun
    Hu, Wei
    Cheng, Wenbo
    Lin, Ling
    ANALYST, 2021, 146 (18) : 5610 - 5618
  • [42] Wireless and Portable Electrochemical Measurement System Integrated With Screen-Printed Immunosensor for VP28 Protein Detection
    Thuy, Linh Huynh Thi
    Nhat, Minh Le Quang
    Dang, Phu Nguyen
    Cao, Hung
    Nguyen, Hung Anh
    Chiao, Jung-Chih
    Jen, Chun-Ping
    Quang, Loc Do
    Duc, Trinh Chu
    Bui, Tung Thanh
    IEEE SENSORS LETTERS, 2024, 8 (10)
  • [43] Development of screen-printed electrode based immunosensor for the detection of HER2 antigen in human serum samples
    Tallapragada, Sagarika Deepthy
    Layek, Keya
    Mukherjee, Runu
    Mistry, Kalyan Kumar
    Ghosh, Monidipa
    BIOELECTROCHEMISTRY, 2017, 118 : 25 - 30
  • [44] A label-free Electrochemical Immunosensor Based on Polythionine-nanogold Nanocomposite for Detection of Trypsin Using screen-printed Electrode
    Hu, Jianxiong
    Li, Quwen
    Chen, Jianhui
    Chen, Shijun
    Cai, Yangfang
    Zhao, Chengfei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (06):
  • [45] Development of highly sensitive electrochemical immunosensor based on single-walled carbon nanotube modified screen-printed carbon electrode
    Nguyen Xuan Viet
    Nguyen Xuan Hoan
    Takamura, Yuzuru
    MATERIALS CHEMISTRY AND PHYSICS, 2019, 227 : 123 - 129
  • [46] An Amperometric Immunosensor for Microcystin-(Leucine-Arginine) Based on Screen-Printed Carbon Electrode
    Chen Xiang-Qiang
    He Miao
    Shi Han-Chang
    Cai Qiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (04) : 443 - 448
  • [47] Folding-based electrochemical DNA sensor fabricated on a gold-plated screen-printed carbon electrode
    Yang, Weiwei
    Gerasimov, Jennifer Y.
    Lai, Rebecca Y.
    CHEMICAL COMMUNICATIONS, 2009, (20) : 2902 - 2904
  • [48] Label-Free Electrochemical Aptasensor for Determination of Chloramphenicol Based on Gold Nanocubes-Modified Screen-Printed Gold Electrode
    Hashkavayi, Ayemeh Bagheri
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Asl, Ezat Hamidi
    ELECTROANALYSIS, 2015, 27 (06) : 1449 - 1456
  • [49] A disposable electrochemical immunosensor based on carbon screen-printed electrodes for the detection of prostate specific antigen
    Yan, Mei
    Zang, Dejin
    Ge, Shenguang
    Ge, Lei
    Yu, Jinghua
    BIOSENSORS & BIOELECTRONICS, 2012, 38 (01): : 355 - 361
  • [50] Rapid Detection of Anti-SARS-CoV-2 Antibodies with a Screen-Printed Electrode Modified with a Spike Glycoprotein Epitope
    Ameku, Wilson A.
    Provance, David W.
    Morel, Carlos M.
    De-Simone, Salvatore G.
    BIOSENSORS-BASEL, 2022, 12 (05):