Portable Electrochemical Immunosensor Based on a Gold Microblobs-Optimized Screen-Printed Electrode for SARS-CoV-2 Diagnosis

被引:0
|
作者
Giacomet, Melissa M. [1 ]
Buzzetti, Paulo H. M. [2 ]
Junior, Oscar O. S. [3 ]
Martins, Alessandro F. [4 ]
Bonafe, Elton G. [1 ]
Monteiro, Johny P. [1 ]
机构
[1] Univ Tecnol Fed Parana UTFPR, Chem Dept, Lab Mat Macromol & Compositos LAMMAC, BR-86812460 Apucarana, PR, Brazil
[2] Univ Grenoble Alpes UGA, Dept Chim Mol DCM, F-38000 Grenoble, France
[3] Univ Estadual Maringa UEM, Chem Dept, BR-87020900 Maringa, PR, Brazil
[4] Pittsburg State Univ, Dept Chem, Pittsburg, KS 66762 USA
关键词
biosensor; COVID-19; gold structure; electrochemistry; portable device; sensing; BIOSENSOR;
D O I
10.3390/inorganics12090252
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The development of biosensors for determining the most diverse biomolecules is a constant focus of many research groups. There is a latent need to propose sensors that combine portability, simple measurements, and good analytical performance. Here, we propose an electrochemical immunosensor that is fully portable and energy-independent for diagnosing antibodies against SARS-CoV-2 (the virus that causes COVID-19). Initially, disposable screen-printed carbon electrodes (SPEs) were covered by gold microblobs (AuMBs), which were synthesized amperometrically from Au3+ ions. Then, the SPE-AuMBs were coated with cysteamine, which allowed the N-hydroxysuccinimide-activated SARS-CoV-2 antigen (spike protein) to be immobilized. The antigen-activated electrode was used to detect COVID-19 antibodies from current measurements obtained by differential pulse voltammetry. The AuMBs synthesis time was optimized, and the presence of gold structures improved the electrochemical responses of the SPE. It was possible to quantitatively determine antibodies in the concentration range of 0.25 to 10 mu g mL-1. This range includes concentrations found in biological fluids from patients at any stage of the disease. An analysis took approximately the same time as traditional rapid nasal tests (20 min) and costed less, considering all the steps necessary to prepare a disposable antigen-functionalized SPE.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Rapid diagnosis of SARS-CoV-2 using potential point-of-care electrochemical immunosensor: Toward the future prospects
    Ranjan, Pushpesh
    Singhal, Ayushi
    Yadav, Shalu
    Kumar, Neeraj
    Murali, S.
    Sanghi, Sunil K.
    Khan, Raju
    INTERNATIONAL REVIEWS OF IMMUNOLOGY, 2021, 40 (1-2) : 126 - 142
  • [42] Enhancement of Electrochemical Properties Using Iron Oxide-Gold Nanocomposite for Tuberculosis Detection Based on rGO-APTES Modified Screen-Printed Electrode
    Amri, Syazana Ameera Syed
    Yusof, Nor Azah
    Abdullah, Jaafar
    Abd Rahman, Siti Fatimah
    Azmi, Umi Zulaikha Mohd
    IEEE SENSORS JOURNAL, 2021, 21 (06) : 7233 - 7241
  • [43] Polymer-modified screen-printed electrode-based electrochemical sensors for doxorubicin detection
    Dimitrievska, Iva
    Paunovic, Perica
    Grozdanov, Anita
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2025, 15 (01):
  • [44] An origami paper-based electrochemical immunoassay for theC-reactive protein using a screen-printed carbon electrode modified with graphene and gold nanoparticles
    Boonkaew, Suchanat
    Chaiyo, Sudkate
    Jampasa, Sakda
    Rengpipat, Sirirat
    Siangproh, Weena
    Chailapakul, Orawon
    MICROCHIMICA ACTA, 2019, 186 (03)
  • [45] Novel approach based on GQD-PHB as anchoring platform for the development of SARS-CoV-2 electrochemical immunosensor
    Martins, Gustavo
    Gogola, Jeferson L.
    Budni, Lucas H.
    Papi, Mauricio A.
    Bom, Maritza A. T.
    Budel, Maria L. T.
    de Souza, Emanuel M.
    Muller-Santos, Marcelo
    Beirao, Breno C. B.
    Banks, Craig E.
    Marcolino-Junior, Luiz H.
    Bergamini, Marcio F.
    ANALYTICA CHIMICA ACTA, 2022, 1232
  • [46] Screen-printed Electrode Based Electrochemical Sensor for the Detection of Isoniazid in Pharmaceutical Formulations and Biological Fluids
    Couto, Rosa A. S.
    Lima, Jose L. F. C.
    Quinaz, M. Beatriz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (10): : 8738 - 8749
  • [47] Biosensor for aluminium(III) based on its inhibition of α-chymotrypsin immobilized on a screen-printed carbon electrode modified with gold nanoparticles
    Miriam Barquero-Quirós
    Olga Domínguez-Renedo
    Maria Asunción Alonso-Lomillo
    María Julia Arcos-Martínez
    Microchimica Acta, 2012, 179 : 65 - 70
  • [48] Polydopamine decorated MoS2 nanosheet based electrochemical immunosensor for sensitive detection of SARS-CoV-2 nucleocapsid protein in clinical samples
    Yadav, Shalu
    Sadique, Mohd Abubakar
    Ranjan, Pushpesh
    Khan, Raju
    Sathish, N.
    Srivastava, Avanish K.
    JOURNAL OF MATERIALS CHEMISTRY B, 2022, 10 (41) : 8478 - 8489
  • [49] Optimization of Aptamer-Based Electrochemical Biosensor for ATP Detection Using Screen-Printed Carbon Electrode/Gold Nanoparticles (SPCE/AuNP)
    Mulyani, Rahmaniar
    Yumna, Nida
    Maksum, Iman Permana
    Subroto, Toto
    Hartati, Yeni Wahyuni
    INDONESIAN JOURNAL OF CHEMISTRY, 2022, 22 (05) : 1256 - 1268
  • [50] An electrochemical biosensor for 3-hydroxybutyrate detection based on screen-printed electrode modified by coenzyme functionalized carbon nanotubes
    Khorsand, Fahimeh
    Azizi, Maedeh Darziani
    Naeemy, Ali
    Larijani, Bagher
    Omidfar, Kobra
    MOLECULAR BIOLOGY REPORTS, 2013, 40 (03) : 2327 - 2334