Vitamin E-stabilized polyethylene shows similar survival rates at minimum 7-year follow-up compared to conventional polyethylene in primary total knee arthroplasty

被引:0
作者
Bistolfi, Alessandro [1 ]
Spezia, Marco [2 ]
Cipolla, Alessandra [3 ]
Bonera, Monica [3 ]
Mellano, Danilo [2 ]
Banci, Lorenzo [4 ]
Colombo, Marta [4 ]
Masse, Alessandro [3 ,5 ]
机构
[1] Cardinal Massaia Asti Hosp, Orthopaed & Traumatol, Asti, Italy
[2] Ctr Ortoped Quadrante Hosp, Omegna, Italy
[3] Univ Studies Turin, Turin, Italy
[4] Permed Orthopaed, Clin Res Dept, Merate, Italy
[5] AOU Citta Salute & Sci Torino, Dept Orthopaed & Traumatol CTO, Turin, Italy
关键词
conventional polyethylene; total knee arthroplasty; UHMWPE; vitamin E; vitamin E-stabilized; CROSS-LINKED POLYETHYLENE; OXIDATION; JOINT; WEAR; UHMWPE; HIP;
D O I
10.1002/jeo2.12106
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThe aim of this cross-sectional study was to compare survival, clinical and radiographic results of total knee arthroplasty (TKA) with vitamin E-stabilized polyethylene (VEPE) or conventional polyethylene (CPE) at a minimum of 7-year follow-up.MethodsPatients who underwent primary TKA between 2011 and 2015, receiving the same cemented rotating platform knee design with VEPE or CPE tibial inserts, were identified. Patients were contacted for clinical and radiographic follow-up. American Knee Society Score (KSS), Forgotten Joint Score (FJS-12), presence of periprosthetic radiolucent lines (RLLs) and osteolysis were evaluated at the last follow-up. Any revision, reintervention or other complications were recorded.ResultsAmong 350 TKAs initially identified, 102 VEPE and 97 CPE knees were included for analysis with mean follow-up of 8.5 and 8.3 years, respectively. No significant difference was found in survival rates at 10-year follow-up with revision due to aseptic loosening (95.0% vs. 97.8%, p = 0.29) or due to any reason (87.6% vs. 89.6%, p = 0.78) between VEPE and CPE TKA. KSS function score resulted significantly higher in the VEPE group over CPE (77 vs. 63, p = 0.01). RLLs were more frequent in VEPE than CPE (54% vs. 32%, p = 0.05), mainly noticed medially and posteriorly beneath the tibial plate, adjacent to the trochlear shield and the posterior condyles. Osteolysis was observed in one knee per group, but patients were asymptomatic with stable implants.ConclusionTKA with VEPE and CPE tibial inserts showed comparable survival rates, complications and clinical and radiographic results up to 10-year follow-up.Level of EvidenceLevel III.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Highly Cross-Linked Polyethylene in Cementless Total Hip Arthroplasty in Patients with Previous Acetabular Fractures: A Minimum 5-Year Follow-Up Study
    Min, Byung-Woo
    Bae, Ki-Cheor
    Cho, Chul-Hyun
    Son, Eun-Suck
    Lee, Kyung-Jae
    Lee, Si-Wook
    INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (SUPPL 2) : 239 - 245
  • [42] Revision total knee arthroplasty with a cemented posterior-stabilized or constrained condylar prosthesis - A minimum 3-year and average 5-year follow-up study
    Peters, CL
    Hennessey, R
    Barden, RM
    Galante, JO
    Rosenberg, AG
    JOURNAL OF ARTHROPLASTY, 1997, 12 (08) : 896 - 903
  • [43] Efficacy of the newly designed "SkyWalker" robot compared to the MAKO robotic system in primary total knee arthroplasty: a one-year follow-up study
    Ping, Hang-Yu
    An, Hao-Ming
    Cao, Zheng
    Nan, Shao-Kui
    Li, Hai-Feng
    Chai, Wei
    INTERNATIONAL ORTHOPAEDICS, 2023, 48 (3) : 761 - 772
  • [44] Efficacy of the newly designed “SkyWalker” robot compared to the MAKO robotic system in primary total knee arthroplasty: a one-year follow-up study
    Hang-Yu Ping
    Hao-Ming An
    Zheng Cao
    Shao-Kui Nan
    Hai-Feng Li
    Wei Chai
    International Orthopaedics, 2024, 48 : 761 - 772
  • [45] 6-year follow-up on migration outcomes: a randomised clinical trial of cemented vitamin E-stabilised highly crosslinked versus standard polyethylene cup in total hip arthroplasty
    Skoldenberg, Olof
    Mukka, Sebastian
    Magneli, Martin
    HIP INTERNATIONAL, 2024, 34 (06) : 695 - 700
  • [46] Higher Dissatisfaction Rate Following Revision Compared With Primary Total Knee Arthroplasty: 1-Year Follow-up of 2151 Primary and 235 Aseptic Revision Surgeries
    Winther, Siri B.
    Klaksvik, Jomar
    Wik, Tina S.
    Husby, Otto S.
    Egeberg, Tarjei
    Snildalsli, Solvi
    Liabakk-Selli, Solvi
    Foss, Olav A.
    ORTHOPEDICS, 2023, 46 (01) : E52 - E57
  • [47] Postoperative posterior pelvic tilt progression is a risk factor for cup revision after total hip arthroplasty with a conventional polyethylene liner: a 25-year follow-up study
    Ueyama, Hideki
    Yamamura, Mitsuyoshi
    Koyanagi, Junichiro
    Fukunaga, Kenji
    Takemura, Susumu
    Nakamura, Suguru
    Kagiyama, Hiroshi
    HIP INTERNATIONAL, 2025,
  • [48] All-polyethylene tibia components have the same functional outcomes and survival, and are more cost-effective than metal-backed components in patients 70 years and older undergoing total knee arthroplasty PROPENSITY MATCH STUDY WITH A MINIMUM FIVE-YEAR FOLLOW-UP
    Jabbal, M.
    Clement, N.
    Walmsley, P. J.
    BONE & JOINT OPEN, 2022, 3 (12): : 969 - 976
  • [49] Patient-specific instrumentation improved clinical outcome and implant survival but is not superior compared to conventional total knee arthroplasty: Ten years follow-up of a multicenter double-blind randomized controlled trial
    Theeuwen, Dieuwertje M. J.
    Dorling, Isobel M.
    Most, Jasper
    van Drumpt, Rogier A. M.
    van der Weegen, Walter
    Welting, Tim J. M.
    Schotanus, Martijn G. M.
    Boonen, Bert
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024,
  • [50] Excellent survival of second-generation uncemented dual mobility cups compared with first-generation cups at a minimum of 10 years follow-up in primary total hip arthroplasty
    Duhil, Antoine
    Delfosse, Gerald
    Servien, Elvire
    Batailler, Cecile
    Lustig, Sebastien
    SICOT-J, 2024, 10