Vitamin E-stabilized polyethylene shows similar survival rates at minimum 7-year follow-up compared to conventional polyethylene in primary total knee arthroplasty

被引:0
作者
Bistolfi, Alessandro [1 ]
Spezia, Marco [2 ]
Cipolla, Alessandra [3 ]
Bonera, Monica [3 ]
Mellano, Danilo [2 ]
Banci, Lorenzo [4 ]
Colombo, Marta [4 ]
Masse, Alessandro [3 ,5 ]
机构
[1] Cardinal Massaia Asti Hosp, Orthopaed & Traumatol, Asti, Italy
[2] Ctr Ortoped Quadrante Hosp, Omegna, Italy
[3] Univ Studies Turin, Turin, Italy
[4] Permed Orthopaed, Clin Res Dept, Merate, Italy
[5] AOU Citta Salute & Sci Torino, Dept Orthopaed & Traumatol CTO, Turin, Italy
关键词
conventional polyethylene; total knee arthroplasty; UHMWPE; vitamin E; vitamin E-stabilized; CROSS-LINKED POLYETHYLENE; OXIDATION; JOINT; WEAR; UHMWPE; HIP;
D O I
10.1002/jeo2.12106
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThe aim of this cross-sectional study was to compare survival, clinical and radiographic results of total knee arthroplasty (TKA) with vitamin E-stabilized polyethylene (VEPE) or conventional polyethylene (CPE) at a minimum of 7-year follow-up.MethodsPatients who underwent primary TKA between 2011 and 2015, receiving the same cemented rotating platform knee design with VEPE or CPE tibial inserts, were identified. Patients were contacted for clinical and radiographic follow-up. American Knee Society Score (KSS), Forgotten Joint Score (FJS-12), presence of periprosthetic radiolucent lines (RLLs) and osteolysis were evaluated at the last follow-up. Any revision, reintervention or other complications were recorded.ResultsAmong 350 TKAs initially identified, 102 VEPE and 97 CPE knees were included for analysis with mean follow-up of 8.5 and 8.3 years, respectively. No significant difference was found in survival rates at 10-year follow-up with revision due to aseptic loosening (95.0% vs. 97.8%, p = 0.29) or due to any reason (87.6% vs. 89.6%, p = 0.78) between VEPE and CPE TKA. KSS function score resulted significantly higher in the VEPE group over CPE (77 vs. 63, p = 0.01). RLLs were more frequent in VEPE than CPE (54% vs. 32%, p = 0.05), mainly noticed medially and posteriorly beneath the tibial plate, adjacent to the trochlear shield and the posterior condyles. Osteolysis was observed in one knee per group, but patients were asymptomatic with stable implants.ConclusionTKA with VEPE and CPE tibial inserts showed comparable survival rates, complications and clinical and radiographic results up to 10-year follow-up.Level of EvidenceLevel III.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] No higher tibial post fracture rate with highly cross-linked polyethylene inserts in total knee arthroplasty at a minimum 10-year follow-up
    Ji-Hoon Baek
    Su Chan Lee
    Suengryol Ryu
    Hye Sun Ahn
    Chang Hyun Nam
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 5807 - 5813
  • [22] Comparison of Survival Rate and Outcomes Between Conventional and Navigation-Assisted Primary Total Knee Arthroplasty in Severe Varus Knees: A Minimum 10-Year Follow-Up
    Lee, Sung-Sahn
    Seo, Min Kyu
    Kim, Il Su
    Moon, Young -Wan
    JOURNAL OF ARTHROPLASTY, 2022, 37 (11) : 2164 - 2170
  • [23] Surface cementation of stemmed tibial components in primary total knee arthroplasty - Minimum 5-year follow-up
    Hofmann, AA
    Goldberg, TD
    Tanner, AM
    Cook, TM
    JOURNAL OF ARTHROPLASTY, 2006, 21 (03) : 353 - 357
  • [24] Autologous Impaction Bone Grafting for Bone Defects of the Medial Tibia Plateau During Primary Total Knee Arthroplasty: Propensity Score Matched Analysis With a Minimum of 7-Year Follow-Up
    Sohn, Jong M.
    In, Yong
    Jeon, Sang H.
    Nho, Jin Y.
    Kim, Man S.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (08) : 2465 - 2470
  • [25] Prospective randomized trial of standard versus highly crosslinked tibial polyethylene in primary posterior-stabilized total knee arthroplasty CLINICAL AND RADIOLOGICAL FOLLOW-UP AT 2 TO 11 YEARS
    Lachiewicz, P. F.
    O'Dell, J. A.
    BONE & JOINT JOURNAL, 2019, 101B (07) : 33 - 39
  • [26] 3-year follow-up of a long-term registry-based multicentre study on vitamin E diffused polyethylene in total hip replacement
    Sillesen, Nanna H.
    Greene, Meridith E.
    Nebergall, Audrey K.
    Huddleston, James I.
    Emerson, Roger
    Gebuhr, Peter
    Troelsen, Anders
    Malchau, Henrik
    HIP INTERNATIONAL, 2016, 26 (01) : 97 - 103
  • [27] Better clinical outcomes and overall higher survival with hybrid versus cemented primary total knee arthroplasty: a minimum 15 years follow-up
    Lizaur-Utrilla, Alejandro
    Miralles-Munoz, Fancisco A.
    Ruiz-Lozano, Matias
    Gonzalez-Parreno, Santiago
    Alonso-Montero, Carolina
    Lopez-Prats, Fernando A.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2021, 29 (03) : 832 - 837
  • [28] Charnley-Kerboull total hip arthroplasty combining zirconia on polyethylene. A minimum eight-year follow-up prospective study
    Langlois, Jean
    El Hage, Samer
    Madi, Faouzi
    Courpied, Jean-Pierre
    Kerboull, Marcel
    Hamadouche, Moussa
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (03) : 355 - 360
  • [29] Highly Cross-Linked Polyethylene in Total Hip Arthroplasty for Osteonecrosis of the Femoral Head: A Minimum 5-Year Follow-Up Study
    Min, Byung-Woo
    Lee, Kyung-Jae
    Song, Kwang-Soon
    Bae, Ki-Cheor
    Cho, Chul-Hyun
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03) : 526 - 530
  • [30] A randomized double-blind noninferiority trial, evaluating migration of a cemented vitamin E-stabilized highly crosslinked component compared with a standard polyethylene component in reverse hybrid total hip arthroplasty
    Skoldenberg, O. G.
    Rysinska, A. D.
    Chammout, G.
    Salemyr, M.
    Mukka, S. S.
    Boden, H.
    Eisler, T.
    BONE & JOINT JOURNAL, 2019, 101B (10) : 1192 - 1198