Vitamin E-stabilized polyethylene shows similar survival rates at minimum 7-year follow-up compared to conventional polyethylene in primary total knee arthroplasty

被引:0
作者
Bistolfi, Alessandro [1 ]
Spezia, Marco [2 ]
Cipolla, Alessandra [3 ]
Bonera, Monica [3 ]
Mellano, Danilo [2 ]
Banci, Lorenzo [4 ]
Colombo, Marta [4 ]
Masse, Alessandro [3 ,5 ]
机构
[1] Cardinal Massaia Asti Hosp, Orthopaed & Traumatol, Asti, Italy
[2] Ctr Ortoped Quadrante Hosp, Omegna, Italy
[3] Univ Studies Turin, Turin, Italy
[4] Permed Orthopaed, Clin Res Dept, Merate, Italy
[5] AOU Citta Salute & Sci Torino, Dept Orthopaed & Traumatol CTO, Turin, Italy
关键词
conventional polyethylene; total knee arthroplasty; UHMWPE; vitamin E; vitamin E-stabilized; CROSS-LINKED POLYETHYLENE; OXIDATION; JOINT; WEAR; UHMWPE; HIP;
D O I
10.1002/jeo2.12106
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThe aim of this cross-sectional study was to compare survival, clinical and radiographic results of total knee arthroplasty (TKA) with vitamin E-stabilized polyethylene (VEPE) or conventional polyethylene (CPE) at a minimum of 7-year follow-up.MethodsPatients who underwent primary TKA between 2011 and 2015, receiving the same cemented rotating platform knee design with VEPE or CPE tibial inserts, were identified. Patients were contacted for clinical and radiographic follow-up. American Knee Society Score (KSS), Forgotten Joint Score (FJS-12), presence of periprosthetic radiolucent lines (RLLs) and osteolysis were evaluated at the last follow-up. Any revision, reintervention or other complications were recorded.ResultsAmong 350 TKAs initially identified, 102 VEPE and 97 CPE knees were included for analysis with mean follow-up of 8.5 and 8.3 years, respectively. No significant difference was found in survival rates at 10-year follow-up with revision due to aseptic loosening (95.0% vs. 97.8%, p = 0.29) or due to any reason (87.6% vs. 89.6%, p = 0.78) between VEPE and CPE TKA. KSS function score resulted significantly higher in the VEPE group over CPE (77 vs. 63, p = 0.01). RLLs were more frequent in VEPE than CPE (54% vs. 32%, p = 0.05), mainly noticed medially and posteriorly beneath the tibial plate, adjacent to the trochlear shield and the posterior condyles. Osteolysis was observed in one knee per group, but patients were asymptomatic with stable implants.ConclusionTKA with VEPE and CPE tibial inserts showed comparable survival rates, complications and clinical and radiographic results up to 10-year follow-up.Level of EvidenceLevel III.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Does Vitamin E-Stabilized Ultrahigh-Molecular-Weight Polyethylene Address Concerns of Cross-Linked Polyethylene in Total Knee Arthroplasty?
    Haider, Hani
    Weisenburger, Joel N.
    Kurtz, Steven M.
    Rimnac, Clare M.
    Freedman, Jordan
    Schroeder, David W.
    Garvin, Kevin L.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (03) : 461 - 469
  • [2] Reasons for Revision, Oxidation, and Damage Mechanisms of Retrieved Vitamin E-Stabilized Highly Crosslinked Polyethylene in Total Knee Arthroplasty
    Spece, Hannah
    Schachtner, Jaclyn T.
    MacDonald, Daniel W.
    Klein, Gregg R.
    Mont, Michael A.
    Lee, Gwo-Chin
    Kurtz, Steven M.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (12) : 3088 - 3093
  • [3] Vitamin E-enriched polyethylene bearings are not inferior to Arcom bearings in primary total knee arthroplasty at medium-term follow-up
    Ftaita, Samy
    Vanden Berghe, Aurelie
    Thienpont, Emmanuel
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (06) : 1027 - 1033
  • [4] Highly Cross-Linked Versus Conventional Polyethylene in Posterior-Stabilized Total Knee Arthroplasty at a Mean 5-Year Follow-up
    Meneghini, R. Michael
    Lovro, Luke R.
    Smits, Shelly A.
    Ireland, Philip H.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (10) : 1736 - 1739
  • [5] High rate of tibial post-fracture in highly cross-linked polyethylene compared to conventional polyethylene in posterior-stabilized total knee arthroplasty at a minimum 12-year follow-up
    Baek, Ji-Hoon
    Lee, Su Chan
    Choi, Kyungwon
    Nam, Chang Hyun
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (12) : 4072 - 4077
  • [6] High rate of tibial post-fracture in highly cross-linked polyethylene compared to conventional polyethylene in posterior-stabilized total knee arthroplasty at a minimum 12-year follow-up
    Ji-Hoon Baek
    Su Chan Lee
    Kyungwon Choi
    Chang Hyun Nam
    Knee Surgery, Sports Traumatology, Arthroscopy, 2022, 30 : 4072 - 4077
  • [7] Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up
    Giustra, Fortunato
    Bistolfi, Alessandro
    Bosco, Francesco
    Fresia, Nicolo
    Sabatini, Luigi
    Berchialla, Paola
    Sciannameo, Veronica
    Masse, Alessandro
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (03) : 1082 - 1088
  • [8] Vitamin E-enriched polyethylene bearings are not inferior to Arcom bearings in primary total knee arthroplasty at medium-term follow-up
    Samy Ftaita
    Aurélie Vanden Berghe
    Emmanuel Thienpont
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1027 - 1033
  • [9] Comparison of a vitamin E-infused highly crosslinked polyethylene insert and a conventional polyethylene insert for primary total knee arthroplasty at two years postoperatively
    Takemura, S.
    Minoda, Y.
    Sugama, R.
    Ohta, Y.
    Nakamura, S.
    Ueyama, H.
    Nakamura, H.
    BONE & JOINT JOURNAL, 2019, 101B (05) : 559 - 564
  • [10] Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up
    Fortunato Giustra
    Alessandro Bistolfi
    Francesco Bosco
    Nicolò Fresia
    Luigi Sabatini
    Paola Berchialla
    Veronica Sciannameo
    Alessandro Massè
    Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 1082 - 1088