A feasibility study to predict 3D dose delivery accuracy for IMRT using DenseNet with log files

被引:0
|
作者
Huang, Ying [1 ,2 ,3 ]
Cai, Ruxin [3 ]
Pi, Yifei [4 ]
Ma, Kui [5 ]
Kong, Qing [1 ]
Zhuo, Weihai [2 ]
Kong, Yan [6 ]
机构
[1] Fudan Univ, Inst Modern Phys, Shanghai, Peoples R China
[2] Fudan Univ, Inst Radiat Med, Shanghai 200032, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Chest Hosp, Sch Med, Shanghai, Peoples R China
[4] hengzhou Univ, Affiliated Hosp 1, Dept Radiat Oncol, Zhengzhou, Henan, Peoples R China
[5] Varian Med Syst, Beijing, Peoples R China
[6] Jiangnan Univ, Dept Radiat Oncol, Affiliated Hosp, Wuxi 214122, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Three-dimensional gamma prediction; log files; patient-specific quality assurance; MLC POSITIONAL ERRORS; CLINICAL IMPLEMENTATION; QUALITY-ASSURANCE; SLIDING WINDOW; RADIOTHERAPY; VERIFICATION; EXPERIENCE;
D O I
10.3233/XST-230412
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
OBJECTIVE: This study aims to explore the feasibility of DenseNet in the establishment of a three-dimensional (3D) gamma prediction model of IMRT based on the actual parameters recorded in the log files during delivery. METHODS: A total of 55 IMRT plans (including 367 fields) were randomly selected. The gamma analysis was performed using gamma criteria of 3% /3 mm (Dose Difference/Distance to Agreement), 3% /2 mm, 2% /3 mm, and 2% /2 mm with a 10% dose threshold. In addition, the log files that recorded the gantry angle, monitor units (MU), multi-leaf collimator (MLC), and jaws position during delivery were collected. These log files were then converted to MU-weighted fluence maps as the input of DenseNet, gamma passing rates (GPRs) under four different gamma criteria as the output, and mean square errors (MSEs) as the loss function of this model. RESULTS: Under different gamma criteria, the accuracy of a 3D GPR prediction model decreased with the implementation of stricter gamma criteria. In the test set, the mean absolute error (MAE) of the prediction model under the gamma criteria of 3% /3 mm, 2% /3 mm, 3% /2 mm, and 2% /2 mm was 1.41, 1.44, 3.29, and 3.54, respectively; the root mean square error (RMSE) was 1.91, 1.85, 4.27, and 4.40, respectively; the Sr was 0.487, 0.554, 0.573, and 0.506, respectively. There was a correlation between predicted and measured GPRs (P < 0.01). Additionally, there was no significant difference in the accuracy between the validation set and the test set. The accuracy in the high GPR group was high, and the MAE in the high GPR group was smaller than that in the low GPR group under four different gamma criteria. CONCLUSIONS: In this study, a 3D GPR prediction model of patient-specific QA using DenseNet was established based on log files. As an auxiliary tool for 3D dose verification in IMRT, this model is expected to improve the accuracy and efficiency of dose validation.
引用
收藏
页码:1199 / 1208
页数:10
相关论文
共 50 条
  • [21] Comparison of 3D and 2D gamma passing rate criteria for detection sensitivity to IMRT delivery errors
    Zhang, Dandan
    Wang, Bin
    Zhang, Guangshun
    Ma, Charlie
    Deng, Xiaowu
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 230 - 238
  • [22] Evaluation of the respiratory motion influence in the 3D dose distribution of IMRT breast radiation therapy treatments
    Lizar, J. C.
    Santos, L. F.
    Brandao, F. C.
    Volpato, K. C.
    Guimaraes, F. S.
    Pavoni, J. F.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [23] Investigation of the feasibility of relative 3D dosimetry in the Radiologic Physics Center Head and Neck IMRT phantom using Presage/optical-CT
    Sakhalkar, Harshad
    Sterling, David
    Adamovics, John
    Ibbott, Geoffrey
    Oldham, Mark
    MEDICAL PHYSICS, 2009, 36 (07) : 3371 - 3377
  • [24] Virtual patient 3D dose reconstruction using in air EPID measurements and a back-projection algorithm for IMRT and VMAT treatments
    Olaciregui-Ruiz, Igor
    Rozendaal, Roel
    van Oers, Rene F. M.
    Mijnheer, Ben
    Mans, Anton
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 37 : 49 - 57
  • [25] Radiomics Analysis of 3D Dose Distributions to Predict Toxicity of Radiotherapy for Cervical Cancer
    Lucia, Francois
    Bourbonne, Vincent
    Visvikis, Dimitris
    Miranda, Omar
    Gujral, Dorothy M.
    Gouders, Dominique
    Dissaux, Gurvan
    Pradier, Olivier
    Tixier, Florent
    Jaouen, Vincent
    Bert, Julien
    Hatt, Mathieu
    Schick, Ulrike
    JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (05):
  • [26] Detection of submillimeter MLC leaf positioning error through log files analysis using Mobius3D
    Cavalli, Nina
    Bonanno, Elisa
    Borzi, Giuseppina
    D'Anna, Alessia
    Pace, Martina
    Stella, Giuseppe
    Zirone, Lucia
    Marino, Carmelo
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3250 - S3251
  • [27] 3D dose reconstruction for narrow beams using ion chamber array measurements
    Schombourg, Karin
    Bochud, Francois O.
    Mirimanoff, Rene-Olivier
    Moeckli, Raphael
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2012, 22 (02): : 123 - 132
  • [28] Reconstructing 3D proton dose distribution using ionoacoustics
    van Dongen, K. W. A.
    de Blecourt, J.
    Lens, E.
    Schaart, D. R.
    Vos, F. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (22)
  • [29] Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm
    Van Uytven, Eric
    Van Beek, Timothy
    McCowan, Peter M.
    Chytyk-Praznik, Krista
    Greer, Peter B.
    McCurdy, Boyd M. C.
    MEDICAL PHYSICS, 2015, 42 (12) : 6945 - 6954
  • [30] A comparative study of dose distribution of PBT, 3D-CRT and IMRT for pediatric brain tumors
    Takizawa, Daichi
    Mizumoto, Masashi
    Yamamoto, Tetsuya
    Oshiro, Yoshiko
    Fukushima, Hiroko
    Fukushima, Takashi
    Terunuma, Toshiyuki
    Okumura, Toshiyuki
    Tsuboi, Koji
    Sakurai, Hideyuki
    RADIATION ONCOLOGY, 2017, 12