A feasibility study to predict 3D dose delivery accuracy for IMRT using DenseNet with log files

被引:0
|
作者
Huang, Ying [1 ,2 ,3 ]
Cai, Ruxin [3 ]
Pi, Yifei [4 ]
Ma, Kui [5 ]
Kong, Qing [1 ]
Zhuo, Weihai [2 ]
Kong, Yan [6 ]
机构
[1] Fudan Univ, Inst Modern Phys, Shanghai, Peoples R China
[2] Fudan Univ, Inst Radiat Med, Shanghai 200032, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Chest Hosp, Sch Med, Shanghai, Peoples R China
[4] hengzhou Univ, Affiliated Hosp 1, Dept Radiat Oncol, Zhengzhou, Henan, Peoples R China
[5] Varian Med Syst, Beijing, Peoples R China
[6] Jiangnan Univ, Dept Radiat Oncol, Affiliated Hosp, Wuxi 214122, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Three-dimensional gamma prediction; log files; patient-specific quality assurance; MLC POSITIONAL ERRORS; CLINICAL IMPLEMENTATION; QUALITY-ASSURANCE; SLIDING WINDOW; RADIOTHERAPY; VERIFICATION; EXPERIENCE;
D O I
10.3233/XST-230412
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
OBJECTIVE: This study aims to explore the feasibility of DenseNet in the establishment of a three-dimensional (3D) gamma prediction model of IMRT based on the actual parameters recorded in the log files during delivery. METHODS: A total of 55 IMRT plans (including 367 fields) were randomly selected. The gamma analysis was performed using gamma criteria of 3% /3 mm (Dose Difference/Distance to Agreement), 3% /2 mm, 2% /3 mm, and 2% /2 mm with a 10% dose threshold. In addition, the log files that recorded the gantry angle, monitor units (MU), multi-leaf collimator (MLC), and jaws position during delivery were collected. These log files were then converted to MU-weighted fluence maps as the input of DenseNet, gamma passing rates (GPRs) under four different gamma criteria as the output, and mean square errors (MSEs) as the loss function of this model. RESULTS: Under different gamma criteria, the accuracy of a 3D GPR prediction model decreased with the implementation of stricter gamma criteria. In the test set, the mean absolute error (MAE) of the prediction model under the gamma criteria of 3% /3 mm, 2% /3 mm, 3% /2 mm, and 2% /2 mm was 1.41, 1.44, 3.29, and 3.54, respectively; the root mean square error (RMSE) was 1.91, 1.85, 4.27, and 4.40, respectively; the Sr was 0.487, 0.554, 0.573, and 0.506, respectively. There was a correlation between predicted and measured GPRs (P < 0.01). Additionally, there was no significant difference in the accuracy between the validation set and the test set. The accuracy in the high GPR group was high, and the MAE in the high GPR group was smaller than that in the low GPR group under four different gamma criteria. CONCLUSIONS: In this study, a 3D GPR prediction model of patient-specific QA using DenseNet was established based on log files. As an auxiliary tool for 3D dose verification in IMRT, this model is expected to improve the accuracy and efficiency of dose validation.
引用
收藏
页码:1199 / 1208
页数:10
相关论文
共 50 条
  • [11] 3D dose reconstruction for clinical evaluation of IMRT pretreatment verification with an EPID
    van Zijtveld, Mathilda
    Dirkx, Maarten L. P.
    de Boer, Hans C. J.
    Heijmen, Ben J. M.
    RADIOTHERAPY AND ONCOLOGY, 2007, 82 (02) : 201 - 207
  • [12] PATIENT-SPECIFIC 3D PRETREATMENT AND POTENTIAL 3D ONLINE DOSE VERIFICATION OF MONTE CARLO-CALCULATED IMRT PROSTATE TREATMENT PLANS
    Boggula, Ramesh
    Jahnke, Lennart
    Wertz, Hansjoerg
    Lohr, Frank
    Wenz, Frederik
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (04): : 1168 - 1175
  • [13] Independent calculation-based verification of IMRT plans using a 3D dose-calculation engine
    Arumugam, Sankar
    Xing, Aitang
    Goozee, Gary
    Holloway, Lois
    MEDICAL DOSIMETRY, 2013, 38 (04) : 376 - 384
  • [14] Feasibility Study of Polymer Gel Dosimetry Using a 3D Printed Phantom for Liver Cancer Radiotherapy
    Minsik Lee
    Seonyeong Noh
    KyoungJun Yoon
    Sang-Wook Lee
    Sang Min Yoon
    Jinhong Jung
    Chiyoung Jeong
    Jungwon Kwak
    Journal of the Korean Physical Society, 2020, 76 : 453 - 457
  • [15] Feasibility Study of Polymer Gel Dosimetry Using a 3D Printed Phantom for Liver Cancer Radiotherapy
    Lee, Minsik
    Noh, Seonyeong
    Yoon, KyoungJun
    Lee, Sang-Wook
    Yoon, Sang Min
    Jung, Jinhong
    Jeong, Chiyoung
    Kwak, Jungwon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (06) : 453 - 457
  • [16] Registration of CT to 3D ultrasound using near-field fiducial localization: A feasibility study
    Kingma, Raoul
    Rohling, Robert N.
    Nguan, Chris
    COMPUTER AIDED SURGERY, 2011, 16 (02) : 54 - 70
  • [17] Evaluation of kV-CBCT based 3D dose calculation accuracy and its validation using delivery fluence derived dose metrics in Head and Neck Cancer
    Shinde, Prashantkumar
    Jadhav, Anand
    Shankar, V.
    Gupta, Karan Kumar
    Dhoble, Nirupama S.
    Dhoble, Sanjay
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 96 : 32 - 45
  • [18] Feasibility of low-dose single-view 3D fiducial tracking concurrent with external beam delivery
    Speidel, Michael A.
    Wilfley, Brian P.
    Hsu, Annie
    Hristov, Dimitre
    MEDICAL PHYSICS, 2012, 39 (04) : 2163 - 2169
  • [19] 3D image guidance in radiotherapy: a feasibility study
    Ebert, M
    Groh, BA
    Partridge, M
    Hesse, BM
    Bortfeld, T
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 1807 - 1816
  • [20] 3D Dose reconstruction: Banding artefacts in cine mode EPID images during VMAT delivery
    Woodruff, H. C.
    Greer, P. B.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444