Sensitive and accurate monitoring of urinary albumin and point-of-care testing using a fluorescent probe with anti-interference capacity against exogenous drugs

被引:2
|
作者
Lu, Cuizhen [1 ,2 ]
Xu, Liang [1 ,2 ]
Jiang, Yu [1 ,2 ]
Liao, Caiqiang [1 ,2 ]
Li, Yixin [1 ,2 ]
Tang, Yinghao [1 ,2 ]
Xu, Zhongyong [3 ]
Du, Xinfeng [4 ]
Lv, Taoyuze [5 ]
Wang, Yalong [1 ,2 ]
Qin, Tianyi [1 ,2 ]
Liu, Bin [3 ]
Zhu, Mingqiang [1 ,2 ]
机构
[1] Hainan Univ, Sch Biomed Engn, State Key Lab Digital Med Engn, Key Lab Biomed Engn Hainan Prov, Sanya 572025, Hainan, Peoples R China
[2] Hainan Univ, One Hlth Inst, Haikou 570228, Hainan, Peoples R China
[3] Shenzhen Univ, Coll Mat Sci & Engn, Shenzhen 518060, Peoples R China
[4] Hainan Univ, State Key Lab Marine Resource Utilizat South China, Haikou 570228, Peoples R China
[5] Univ Sydney, Sch Phys, Sydney, NSW 2006, Australia
基金
海南省自然科学基金; 中国国家自然科学基金;
关键词
Fluorescent probe; Urinary albumin; Point-of-care testing; Anti-interference; HUMAN SERUM-ALBUMIN; DIAGNOSIS; NSAIDS; CKD;
D O I
10.1016/j.talanta.2024.126575
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fluorescent probes have been reported for monitoring urinary albumin (u-ALB) to enable early diagnosis of kidney diseases and facilitate regular point-of-care testing (POCT) for chronic kidney disease (CKD) patients. However, the albumin can bind hydrophobic drugs through host-guest interactions, which may result in decreased accuracy of probes at regular drug sites and hamper POCT of albuminuria since CKD patients often need to take medications routinely. Herein, we reported a novel fluorescent probe (NC-2) by molecular engineering of a reported AIEgen (NC-1). The introduction of a non-conjugated ring moiety to the molecular rotor granted the NC-2 enhanced sensitivity with a limit of detection in urine of 8.7 mg/L, which is below l the threshold of microalbuminuria (30 mg/L). Moreover, the NC-2 was found to preferentially bind to the FA1 site of ALB, conferring it with excellent anti-interference capacities against exogenous drug molecules and metabolites. Simulation experiments using lab-spiked urine samples containing common drugs taken by CKD patients demonstrated that the probe could provide satisfied detecting accuracy (80-90 %). Furthermore, a paper-based device was constructed and achieved on-site detection of u-ALB in qualitative and semi-quantitative manners. Findings in this work were of great significance to the development of fluorescent probes for accurate detection of ALB in complex urine samples and the further achievement of fluorescence-based POCT for CKD.
引用
收藏
页数:10
相关论文
共 10 条
  • [1] An anti-interference fluorescent probe for point-of-care diagnosis of albuminuria
    Zhao, Xiongfei
    Zheng, Weidong
    Qin, Tianyi
    Du, Xinfeng
    Lei, Yanmei
    Lv, Taoyuze
    Zhou, Mei
    Xu, Zhongyong
    Wang, Lei
    Liu, Bin
    Peng, Xiaojun
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 351
  • [2] Rational design of a FA1-targeting anti-interference fluorescent probe for the point-of-care testing of albuminuria
    Deng, Weihua
    Xu, Zhongyong
    Li, Na
    Lv, Taoyuze
    Wang, Lei
    Li, Mingle
    Chen, Xiaoqiang
    Liu, Bin
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2024, 261
  • [3] Rational design of donor-acceptor fluorescent probe for the ratiometric point-of-care testing of human serum albumin
    Chen, Zihao
    Xu, Zhongyong
    Qin, Tianyi
    Wang, Dagang
    Zhang, Shiwei
    Lv, Taoyuze
    Wang, Lei
    Chen, Xiaoqiang
    Liu, Bin
    Peng, Xiaojun
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 398
  • [4] A point-of-care testing assay for clonorchiasis using a EuNPs-CsTR1 fluorescent probe-based immunoassay
    Ma, Xiaoxiao
    Zhang, Huiyuan
    Fang, Yiming
    Wang, Jing
    Wang, Xingyang
    Li, Chen
    Liu, Xiaolei
    Liu, Mingyuan
    Tang, Bin
    Liu, Yi
    PLOS NEGLECTED TROPICAL DISEASES, 2024, 18 (04):
  • [5] Monitoring the efficiency of reversal on anti-Xa direct oral anticoagulants using point-of-care viscoelastic testing
    Heubner, Lars
    Grottke, Oliver
    Vicent, Oliver
    Spieth, Peter Markus
    Beyer-Westendorf, Jan
    THROMBOSIS JOURNAL, 2024, 22 (01):
  • [6] Accurate CD4 T-cell enumeration and antiretroviral drug toxicity monitoring in primary healthcare clinics using point-of-care testing
    Jani, Ilesh V.
    Sitoe, Nadia E.
    Chongo, Patrina L.
    Alfai, Eunice R.
    Quevedo, Jorge I.
    Tobaiwa, Ocean
    Lehe, Jonathan D.
    Peter, Trevor F.
    AIDS, 2011, 25 (06) : 807 - 812
  • [7] A Smartphone Optical Device for Point-of-Care Testing of Glucose and Cholesterol Using Ag NPs/UiO-66-NH2 -Based Ratiometric Fluorescent Probe
    Guo, Lan
    Chen, Shuai
    Yu, Yong-Liang
    Wang, Jian-Hua
    ANALYTICAL CHEMISTRY, 2021, 93 (48) : 16240 - 16247
  • [8] An enhanced fluorescent probe through the strategy of using MgWO4 nanosheets to enhance terbium ion luminescence for highly sensitive and point-of-care visual quantitative testing of ciprofloxacin integrated with a low-cost smartphone-based platform
    Zhang, Jingfei
    Zhang, Yu
    Shi, Guoyue
    ANALYST, 2021, 146 (24) : 7710 - 7719
  • [9] Rapid, label-free, and sensitive point-of-care testing of anti-SARS-CoV-2 IgM/IgG using all-fiber Fresnel reflection microfluidic biosensor
    Wenjuan Xu
    Jiayao Liu
    Dan Song
    Chunsheng Li
    Anna Zhu
    Feng Long
    Microchimica Acta, 2021, 188
  • [10] Rapid, label-free, and sensitive point-of-care testing of anti-SARS-CoV-2 IgM/IgG using all-fiber Fresnel reflection microfluidic biosensor
    Xu, Wenjuan
    Liu, Jiayao
    Song, Dan
    Li, Chunsheng
    Zhu, Anna
    Long, Feng
    MICROCHIMICA ACTA, 2021, 188 (08)