A novel multi-channel applicator with a U-shaped channel for vaginal intracavity brachytherapy

被引:0
|
作者
Lu, Yanfei [1 ,2 ]
Chen, Jianhong [1 ,2 ]
Wang, Fangfang [1 ,2 ]
Zhou, Qiong [1 ,2 ]
Zhang, Xiang [1 ,2 ]
机构
[1] Zhejiang Canc Hosp, Hangzhou 310022, Zhejiang, Peoples R China
[2] Chinese Acad Sci, Hangzhou Inst Med HIM, Hangzhou, Zhejiang, Peoples R China
来源
关键词
applicator; brachytherapy; dose distribution; endometrial cancer; HIGH-DOSE-RATE; ENDOMETRIAL CANCER; CUFF BRACHYTHERAPY; GUIDELINES;
D O I
10.1002/acm2.14521
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Endometrial cancer is one of the most common gynecological malignancies in the world. Vaginal brachytherapy is an important postoperative adjuvant treatment for endometrial cancer. However, a common problem with existing applicators is insufficient dose at the vaginal apex. Purpose: This study describes the Hangzhou (HZ) cylinder, a novel 3D printed vaginal intracavity brachytherapy applicator, detailing its characteristics, dose distribution, and clinical applications. Methods and materials: The HZ cylinder is distinguished by its unique structure: a U-shaped channel with a 2 mm diameter, a straight central axis channel of the same diameter, and 10 parallel straight channels. For comparison, standard plans were employed, designed to ensure that a minimum of 95% of the prescribed dose reached 5 mm beneath the mucosal surface. We conducted comparative analyses of mucosal surface doses and doses at a 5 mm depth below the mucosa between the HZ cylinder and a conventional single-channel cylinder across various treatment schemes. Additionally, the study examined dose differences in target volume and organs at risk (OARs) between actual HZ cylinder plans and hypothetical single-channel plans. Results: In the standard plans, mucosal surface doses at the apex of the vagina were 209.32% and 200.61% of the prescribed dose with the HZ and single-channel cylinders, respectively. The doses on the left and right wall mucosal surfaces varied from 149.26% to 178.13% and 142.98% to 180.75% of the prescribed dose, and on the anterior and posterior wall mucosal surfaces varied from 128.87% to 138.50% and 142.98% to 180.75% of the prescribed dose. Analysis of 24 actual treatment plans revealed that when the vaginal tissue volume dose covering 98% (vaginal D98%) was comparable between the HZ cylinder and virtual single-channel plans (6.74 +/- 0.07 Gy vs. 6.69 +/- 0.10 Gy, p = 0.24), rectum doses of HZ cylinder plans were significantly lower than those of single-channel plans (D1cc, 5.96 +/- 0.56 Gy vs. 6.26 +/- 0.71 Gy, p = 0.02 and D2cc, 5.26 +/- 0.52 Gy vs. 5.56 +/- 0.62 Gy, p = 0.02). Conclusions: The HZ cylinder demonstrates a reduction in dose to the rectum and bladder while maintaining adequate target volume coverage. Its mucosal surface dose is comparable to that of the traditional single-channel cylinder. These findings suggest that the HZ cylinder is a viable and potentially safer alternative for vaginal brachytherapy, warranting further investigation with larger sample sizes.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] An Optimized Dosimetric Study of a Multi-Channel Vaginal Cylindrical Applicator in Brachytherapy
    Syh, J.
    Syh, J.
    Wu, H.
    White, M.
    Patel, B.
    Rosen, L.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [2] Intensity-modulated vaginal brachytherapy applicator and single- and multi-channel applicators in vaginal cuff brachytherapy
    Biltekin, Fatih
    Akyol, Husnu Fadil
    Gultekin, Melis
    Yilmaz, Melek Tugce
    Yildiz, Ferah
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2024, 16 (02) : 132 - 138
  • [3] Use of a flexible inflatable multi-channel applicator for vaginal brachytherapy in the management of gynecologic cancer
    Shin, Samuel M.
    Duckworth, Tamara L.
    Cooper, Benjamin T.
    Curtin, John P.
    Schiff, Peter B.
    DeWyngaert, J. Keith
    Lymberis, Stella C.
    FRONTIERS IN ONCOLOGY, 2015, 5
  • [4] 3D-PRINTED MULTI-CHANNEL VAGINAL APPLICATOR FOR BRACHYTHERAPY IN GYNECOLOGICAL CANCER
    Logar, Helena
    Hudej, Robert
    Kobav, Manja
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2020, 30 : A102 - A103
  • [5] Comparison of standard single-channel vaginal cylinder to the multi-channel wright applicator for HDR vaginal brachytherapy in endometrial carcinoma
    Malik, U
    Meigooni, AS
    Yoneda, J
    Payne, T
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S480 - S480
  • [6] Dosimetric Characterization of a New HDR Multi-Channel Esophageal Applicator for Brachytherapy
    Zhao, A.
    Diener, T.
    Gao, S.
    Greskovich, J.
    Wilkinson, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3664 - 3664
  • [7] Research and application of multi-channel SPR sensor cascaded with fiber U-shaped structure
    Wang, Rui
    Liu, Chunlan
    Wei, Yong
    Jiang, Tianci
    Liu, Chunbiao
    Shi, Chen
    Zhao, Xiaoling
    Li, Lingling
    OPTIK, 2022, 266
  • [8] A Novel Multi -Channel Tandem Applicator for Direction Modulated Brachytherapy
    Meftahi, M.
    Song, W. Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E534 - E534
  • [9] Preliminary clinical outcomes of patients treated with vaginal brachytherapy alone using multi-channel vaginal brachytherapy applicator in operated early-stage endometrial cancer
    Rishi, Karthik S.
    David, Savitha
    Pathikonda, Muddappa
    Ramachandra, Prakash
    Giri, G., V
    Vadaparty, Annapurna
    Srinath, B. S.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2021, 26 (01) : 43 - 49
  • [10] Flow Structures in a U-Shaped Channel
    Wang, You Qin
    Jackson, Peter L.
    Phaneuf, Timothy J.
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2009, 23 (01) : 106 - 119