The goal of the present work was to conduct an initial screening survey of several types of TL and OSL detectors, aimed at searching for the indication of the presence of dose rate effects. The study has been performed on ten different materials: LiF:Mg,Ti; LiF:Mg,Cu,P; CaF2:Dy; 2 :Dy; Al-P glass; YAP:Mn; CaSO4:Dy; 4 :Dy; Al2O3:C; 2 O 3 :C; BeO; MgB4O7: 4 O 7 : Ce.Li and quartz. Gamma-ray dose rates ranged from 0.1 mGy/h to 90 Gy/h. No clear evidence of dose rate effects was found for any material. In two cases (MgB4O7: 4 O 7 : Ce,Li and BeO) some irregularities of the response were observed, which require further investigations but most probably they are not attributable to the dose rate influence.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Assessing dose rate effects in TL and OSL dosimeters: A critical look into dose rate models
    Motta, S.
    Yukihara, E. G.
    RADIATION MEASUREMENTS, 2024, 179
  • [2] RELATIVE TL AND OSL EFFICIENCY TO PROTONS OF VARIOUS DOSIMETRIC MATERIALS
    Sadel, M.
    Bilski, P.
    Swakon, J.
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 112 - 115
  • [3] Investigation of TL and OSL detectors in ultra-high dose rate electron beams
    Motta, S.
    Christensen, J. B.
    Frei, F.
    Peier, P.
    Yukihara, E. G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (14):
  • [4] TL and OSL dosimetric characterization of different luminescent materials for clinical electron beams application in TSEB treatments
    Almeida, S. B.
    Villani, D.
    Sakuraba, R. K.
    Rezende, A. C. P.
    Campos, L. L.
    JOURNAL OF LUMINESCENCE, 2018, 198 : 497 - 501
  • [5] Time and dose-rate dependence of TL and OSL due to competition between excitation and fading
    Chen, R.
    Pagonis, V.
    Lawless, J. L.
    RADIATION MEASUREMENTS, 2015, 82 : 115 - 121
  • [6] OSL diagnostics of luminescent materials in a scanning electron microscope
    A. S. Vokhmintsev
    I. A. Weinstein
    M. S. Karabanalov
    Ya. G. Smorodinskii
    Russian Journal of Nondestructive Testing, 2014, 50 : 736 - 740
  • [7] OSL Diagnostics of Luminescent Materials in a Scanning Electron Microscope
    Vokhmintsev, A. S.
    Weinstein, I. A.
    Karabanalov, M. S.
    Smorodinskii, Ya. G.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2014, 50 (12) : 736 - 740
  • [8] Monte Carlo simulations of TL and OSL in nanodosimetric materials and feldspars
    Pagonis, Vasilis
    Chen, Reuven
    RADIATION MEASUREMENTS, 2015, 81 : 262 - 269
  • [9] Superlinear dose response of thermoluminescence (TL) and optically stimulated luminescence (OSL) signals in luminescence materials: An analytical approach
    Pagonis, Vasilis
    Chen, Reuven
    Lawless, John L.
    JOURNAL OF LUMINESCENCE, 2012, 132 (06) : 1446 - 1455
  • [10] Monitoring environmental dose rate using Riso TL/OSL readers with built-in sources:: recommendations for users
    Kalchgruber, R
    Göksu, HY
    Hochhäuser, E
    Wagner, GA
    RADIATION MEASUREMENTS, 2002, 35 (06) : 585 - 590