Tuned Liquid Column Damper Inerter (TLCDI) for Wind-Induced Vibration Control of Fixed-Base Structures

被引:0
作者
Chiara, Masnata [1 ]
Di Matteo, Alberto [1 ]
Adam, Christoph [2 ]
Pirrotta, Antonina [1 ]
机构
[1] Univ Palermo, Dept Engn, Palermo, Italy
[2] Univ Innsbruck, Unit Appl Mech, Innsbruck, Austria
来源
PERSPECTIVES IN DYNAMICAL SYSTEMS I-APPLICATIONS, DSTA 2021 | 2024年 / 453卷
关键词
Tuned liquid column damper; Inerter; Optimal design; Statistical linearization technique; MASS-DAMPER; RESPONSE CONTROL; OPTIMAL-DESIGN; PERFORMANCE; SYSTEMS;
D O I
10.1007/978-3-031-56492-5_26
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
In this paper, the optimal design of a novel passive control device, defined as Tuned Liquid Column Damper Inerter (TLCDI), is investigated to control wind-induced vibrations of structural systems. Due to inherent nonlinearities, a complex numerical solution scheme is commonly required to optimally design the device. Therefore, to provide a straightforward optimization procedure, a statistical linearization approach is employed to minimize the stochastic response of a single degree of freedom system. Under the assumption of a Gaussian white noise excitation of wind loading type, and considering some additional hypotheses, a closed form solution of the optimal parameters of TLCDI is achieved. The validity of the proposed expressions is assessed by comparing results with those obtained from a more computationally demanding iterative method.
引用
收藏
页码:351 / 368
页数:18
相关论文
共 37 条
[1]   EFFECTIVENESS OF TUNED LIQUID COLUMN DAMPERS FOR VIBRATION CONTROL OF TOWERS [J].
BALENDRA, T ;
WANG, CM ;
CHEONG, HF .
ENGINEERING STRUCTURES, 1995, 17 (09) :668-675
[2]   Mass ratio factor for optimum tuned mass damper strategies [J].
Bekdas, Gebrail ;
Nigdeli, Sinan Melih .
INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2013, 71 :68-84
[3]   Mass dampers and their optimal designs for building vibration control [J].
Chang, CC .
ENGINEERING STRUCTURES, 1999, 21 (05) :454-463
[4]   Control performance of liquid column vibration absorbers [J].
Chang, CC ;
Hsu, CT .
ENGINEERING STRUCTURES, 1998, 20 (07) :580-586
[5]   Closed-form optimal calibration of a tuned liquid column damper (TLCD) for flexible structures [J].
Chen, Bei ;
Zhang, Zili ;
Hua, Xugang .
INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2021, 198 (198)
[6]  
Den Hartog J.P., 1985, MECH VIBRATIONS, DOI DOI 10.1038/161503C0
[7]   Simplified analytical solution for the optimal design of Tuned Mass Damper Inerter for base isolated structures [J].
Di Matteo, A. ;
Masnata, C. ;
Pirrotta, A. .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 134
[8]   Direct evaluation of the equivalent linear damping for TLCD systems in random vibration for pre-design purposes [J].
Di Matteo, A. ;
Lo Iacono, F. ;
Navarra, G. ;
Pirrotta, A. .
INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 2014, 63 :19-30
[9]   Optimal design of tuned liquid column damper inerter for vibration control [J].
Di Matteo, Alberto ;
Masnata, Chiara ;
Adam, Christoph ;
Pirrotta, Antonina .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2022, 167
[10]   Optimal design of tuned liquid column dampers for seismic response control of base-isolated structures [J].
Di Matteo, Alberto ;
Furtmueller, Thomas ;
Adam, Christoph ;
Pirrotta, Antonina .
ACTA MECHANICA, 2018, 229 (02) :437-454