摘要
In this paper, buckling conditions and retrofitting of cylindrical steel water storage tanks with different roof types and wall thicknesses were investigated by using finite element method. Four roof types of cylindrical steel tanks which are opentop, flat-closed, conical-closed and torispherical-closed and three wall thicknesses of 4, 6 and 8 mm were considered in FE modeling of cylindrical steel tanks. The roof shapes significantly affect load distribution on the tank shell under the seismic action. Composite FRP materials are widely used for winding thin-walled cylindrical steel structures. The retrofitting efficiency of cylindrical steel water tank is tested under the seismic loading with the externally bonded CFRP laminates. In retrofitting of cylindrical steel tank, the CFRP composite material coating method was used to improve of seismic performance of cylindrical steel tanks. ANSYS software was used to analyze the cylindrical steel tanks and maximum equivalent (von-Mises) and directional deformation were obtained. Equivalent (von-Mises) stresses significantly decreased due to the coating of the tank shell with FRP composite material. In thin-walled steel structures, excessive stress causes buckling and deformations. Therefore, retrofitting led to decrease in stress, reductions in directional and buckling deformation of the open-top, flat-closed, conicalclosed and torispherical-closed tanks.
引用
收藏
页码:97 / 111
页数:15
相关论文
共 91 条
  • [1] Experimental analysis of reinforced concrete shear deficient beams with circular web openings strengthened by CFRP composite
    Aksoylu, Ceyhun
    Yazman, Sakir
    Ozkilic, Yasin Onuralp
    Gemi, Lokman
    Arslan, Musa Hakan
    [J]. COMPOSITE STRUCTURES, 2020, 249
  • [2] Alliance A.L., 2001, Seismic Fragility Formulations for Water Systems: Guideline
  • [3] [Anonymous], 2004, EUROCODE 8 DESIGN ST
  • [4] Seismic intensity measures for above-ground liquid storage tanks
    Bakalis, Konstantinos
    Kohrangi, Mohsen
    Vamvatsikos, Dimitrios
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2018, 47 (09) : 1844 - 1863
  • [5] Seismic risk assessment of liquid storage tanks via a nonlinear surrogate model
    Bakalis, Konstantinos
    Vamvatsikos, Dimitrios
    Fragiadakis, Michalis
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2017, 46 (15) : 2851 - 2868
  • [6] FREE-VIBRATION ANALYSIS OF CYLINDRICAL LIQUID STORAGE TANKS
    BALENDRA, T
    ANG, KK
    PARAMASIVAM, P
    LEE, SL
    [J]. INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 1982, 24 (01) : 47 - 59
  • [7] Bauer H.F., 1964, FLUID OSCILLATIONS C
  • [8] Brebbia C.A., 2011, Boundary Elements and Other Mesh Reduction Methods XXXIII
  • [9] Seismic Performance of Storage Steel Tanks during the May 2012 Emilia, Italy, Earthquakes
    Brunesi, Emanuele
    Nascimbene, Roberto
    Pagani, Marco
    Beilic, Dumitru
    [J]. JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2015, 29 (05)
  • [10] Dynamic buckling and seismic fragility of anchored steel tanks by the added mass method
    Buratti, N.
    Tavano, M.
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2014, 43 (01) : 1 - 21