共 33 条
Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®
被引:1
作者:
Mihalinec, Katja
[1
]
Martinez-Cepa, Carmen B.
[2
]
Zuil-Escobar, Juan C.
[2
]
Kejzar, Natasa
[3
]
Vauhnik, Renata
[1
,4
]
机构:
[1] Univ Ljubljana, Fac Hlth Sci, Dept Physiotherapy, Biomech Lab, Zdravstvena Pot 5, Ljubljana 1000, Slovenia
[2] CEU Univ, Univ San Pablo CEU, Fac Med, Dept Fisioterapia,Urbanizac Monteprincipe, Boadilla Del Monte, Spain
[3] Univ Ljubljana, Inst Biostat & Med Informat, Fac Med, Ljubljana, Slovenia
[4] Arthron, Inst Joint & Sports Injuries, Ukmarjeva 2, Ljubljana, Slovenia
关键词:
anterior laxity;
arthrometry;
rotational laxity;
reliability;
ANTERIOR CRUCIATE LIGAMENT;
ROTATIONAL KNEE LAXITY;
IN-VIVO;
VARUS-VALGUS;
HEALTHY;
INJURIES;
D O I:
10.1002/jeo2.70026
中图分类号:
R826.8 [整形外科学];
R782.2 [口腔颌面部整形外科学];
R726.2 [小儿整形外科学];
R62 [整形外科学(修复外科学)];
学科分类号:
摘要:
PurposeThe purpose of our study was to test the intra-rater and inter-rater reliability of the DYNEELAX (R) arthrometer in healthy subjects. Since rotational laxity will be measured for the first time in humans, indications for normative values will also be presented.MethodsKnee anterior laxity and rotational laxity using a DYNEELAX (R) arthrometer were assessed in 73 subjects (39 females and 34 males). An intraclass correlation coefficient was calculated to evaluate the intra-rater and inter-rater reliability of the DYNEELAX (R).ResultsAn intraclass correlation coefficient for intra-rater reliability ranges from 0.631 (95% confidence interval; [CI]: 0.47-0.75) to 0.699 (95% CI: 0.56-0.80) and from 0.916 (95% CI: 0.87-0.95) to 0.94 (95% CI: 0.91-0.96) for anterior knee laxity and rotational knee laxity, respectively. An intraclass correlation coefficient for inter-rater reliability ranges from 0.578 (95% CI: 0.40-0.71) to 0.646 (95% CI: 0.44-0.78) and from 0.822 (95% CI: 0.57-0.91) to 0.933 (95% CI: 0.89-0.96) for anterior knee laxity and rotational knee laxity, respectively.ConclusionsThe DYNEELAX (R) arthrometer has good to excellent intra-rater and inter-rater reliability for rotational knee laxity and moderate intra-rater reliability for anterior knee laxity in healthy subjects. Future studies should investigate the clinical significance of anterior and rotational laxity measured with the DYNEELAX (R) arthrometer in patients with knee pathology, as both laxities are critical for assessing the integrity of the intra-articular structures of the knee in clinical practice.Level of evidenceLevel IV.
引用
收藏
页数:9
相关论文