Accuracy of Marginal Reflex Distance Measurements in Eyelid Surgery

被引:32
作者
Nemet, Arie Y. [1 ]
机构
[1] Meir Med Ctr, Dept Ophthalmol, Tchernichovsky 59, IL-4428164 Kefar Sava, Israel
关键词
Eyelid surgery; marginal reflex distance; measurements; ptosis;
D O I
10.1097/SCS.0000000000001304
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The marginal reflex distance (MRD), the position of the eyelids with the eyes in the primary position, is fundamental to patient assessment and surgery choice in facial and ophthalmic plastic surgery. This study compares the accuracy of handheld ruler and slit lamp biomicroscope measurements of the MRD1 in patients with blepharoptosis. Methods: This is a prospective study of 85 consecutive patients who were referred to our oculoplastic clinic between 2011 and 2013 for unilateral or bilateral ptosis repair. The MRD1 was measured by 2 techniques: 1. With the use of a penlight to illuminate the cornea, the corneal light reflex is observed, and the distance between the cornea and the upper lid margin is recorded. 2. Slit lamp biomicroscope assessment. A comparison between those 2 methods was performed. Results: The mean (SD) MRD1 was 1.18 (1.11) mm and 1.06 (1.18) mm with a penlight and a slit lamp, respectively. There was a significant difference between the 2 measurements, but they were highly correlated in the paired t-test and the Wilcoxon test. The intraclass correlation coefficient was 0.984, representing excellent reliability. Conclusions: The MRD1 measured by a skilled clinician yields reliable results using a penlight and a ruler. In some cases, measurement of eyelid heights (palpebral fissure, MRD1, brow position) is challenging. The use of a slit lamp biomicroscope and a close front photograph may help determine accurate measurements.
引用
收藏
页码:E569 / E571
页数:3
相关论文
共 14 条
  • [1] Blepharoptosis: Evaluation, techniques, and complications
    Ahmad, Syed M.
    Della Rocca, Robert C.
    [J]. FACIAL PLASTIC SURGERY, 2007, 23 (03) : 203 - 215
  • [2] Repeatability and reproducibility of upper eyelid measurements
    Boboridis, K
    Assi, A
    Indar, A
    Bunce, C
    Tyers, AG
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (01) : 99 - 101
  • [3] Collin JRO, 1989, A manual of systematic eyelid surgery, V2nd, P41
  • [4] A standardized digital photography system-with computerized eyelid measurement analysis
    Coombes, Andrew G.
    Sethi, Charanjit S.
    Kirkpatrick, W. Niall
    Waterhouse, Norman
    Kelly, Martin H.
    Joshi, Naresh
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 120 (03) : 647 - 656
  • [5] Farkas LG, 1996, CLEFT PALATE-CRAN J, V33, P10, DOI 10.1597/1545-1569(1996)033<0010:AOAMPP>2.3.CO
  • [6] 2
  • [7] Karesh J W, 1994, Facial Plast Surg, V10, P185, DOI 10.1055/s-2008-1064569
  • [8] PREVALENCE OF PALPEBRAL FISSURE ASYMMETRY IN WHITE PERSONS
    LAM, BL
    LAM, S
    WALLS, RC
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 120 (04) : 518 - 522
  • [9] Circadian rhythms in the human pupil and eyelid
    Loving, RT
    Kripke, DF
    Glazner, LK
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 1996, 271 (02) : R320 - R324
  • [10] Margin Reflex Distance in Different Ethnic Groups
    Murchison, Ann P.
    Sires, Bryan A.
    Jian-Amadi, Arash
    [J]. ARCHIVES OF FACIAL PLASTIC SURGERY, 2009, 11 (05) : 303 - 305