Early Radiographic and Clinical Outcomes of Robotic-arm-assisted versus Conventional Total Knee Arthroplasty: A Multicenter Randomized Controlled Trial

被引:4
作者
Geng, Xiao [1 ]
Zheng, Yuhang [1 ]
Li, Yang [1 ]
Zhao, Minwei [1 ]
Liu, Yanqing [1 ]
Li, Zijian [1 ]
Cai, Hong [1 ]
Zhang, Ming [2 ]
Yan, Xinfeng [2 ]
Sun, Zhiwen [3 ]
Lv, Xin [3 ]
Guo, Feng [3 ]
Li, Feng [1 ]
Tian, Hua [1 ]
机构
[1] Peking Univ Third Hosp, Dept Orthopaed Engn Res Ctr Bone & Joint Precis Me, Beijing Key Lab Spinal Dis Res, Minist Educ, Beijing, Peoples R China
[2] Shandong First Med Univ, Shandong Prov Qianfoshan Hosp, Affiliated Hosp 1, Jinan, Peoples R China
[3] Chifeng Municipal Hosp, Chifeng, Inner Mongolia, Peoples R China
关键词
Clinical outcome; Radiological outcome; Robotic-arm-assisted; Total knee arthroplasty; NAVIGATION; ALIGNMENT; TKA; IMPLANTATION; IMPROVES; AXIS;
D O I
10.1111/os.14196
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectiveA robotic system was recently introduced to improve prosthetic alignment during total knee arthroplasty (TKA). The purpose of this multicenter, prospective, randomized controlled trial (RCT) was to determine whether robotic-arm-assisted TKA improves clinical and radiological outcomes when compared to conventional TKA. MethodsOne hundred and thirty patients who underwent primary TKA were enrolled in this prospective, randomized controlled trial, which was conducted at three hospitals. Five patients were lost to follow-up 6 weeks after surgery. Therefore, 125 participants (63 in the intervention group and 62 in the control group) remained in the final analysis. The primary outcome was the rate at which the mechanical axis of the femur deviated by less than 3 degrees from the mechanical axis of the tibia. This was evaluated by full-length weight-bearing X-rays of the lower limb 6 weeks postoperatively. Secondary outcomes included operation times, 6-week postoperative functional outcomes evaluated by the American Knee Society score (KSS) and the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), short form-36 (SF-36) health survey results, and the occurrence of adverse events (AEs) and serious adverse events (SAEs). ResultsAt 6 weeks postoperatively, we found that the rate of radiographic inliers was significantly higher in the intervention group (78.7% vs 51.6%; p = 0.00; 95% confidence interval, 10.9% to 43.2%). The operation was significantly longer in the intervention group than in the control group (119.5 vs 85.0 min; p = 0.00). There were no significant differences in the 6-week postoperative functional outcomes, SF-36, AEs, and SAEs between the two groups. There were no AEs or SAEs that were determined to be "positively related" to the robotic system. ConclusionRobotic-arm-assisted TKA is safe and effective, as demonstrated in this trial.
引用
收藏
页码:2732 / 2740
页数:9
相关论文
共 43 条
[21]   Navigation and robotics improved alignment compared with PSI and conventional instrument, while clinical outcomes were similar in TKA: a network meta-analysis [J].
Lei, Kai ;
Liu, LiMing ;
Chen, Xin ;
Feng, Qing ;
Yang, Liu ;
Guo, Lin .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (02) :721-733
[22]   Robot-Assisted Total Knee Arthroplasty Accurately Restores the Joint Line and Mechanical Axis. A Prospective Randomised Study [J].
Liow, Ming Han Lincoln ;
Xia, Zhan ;
Wong, Merng Koon ;
Tay, Keng Jin ;
Yeo, Seng Jin ;
Chin, Pak Lin .
JOURNAL OF ARTHROPLASTY, 2014, 29 (12) :2373-2377
[23]   Minimal clinically important differences and substantial clinical benefits for Knee Society Scores [J].
Lizaur-Utrilla, Alejandro ;
Gonzalez-Parreno, Santiago ;
Martinez-Mendez, Daniel ;
Miralles-Munoz, Francisco A. ;
Lopez-Prats, Fernando A. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (05) :1473-1478
[24]   Comparison of navigation systems for total knee arthroplasty: A systematic review and meta-analysis [J].
Luan, Yichao ;
Wang, Huizhi ;
Zhang, Min ;
Li, Junwei ;
Zhang, Ningze ;
Liu, Bolun ;
Su, Jian ;
Fang, Chaohua ;
Cheng, Cheng-Kung .
FRONTIERS IN SURGERY, 2023, 10
[25]  
Maredupaka S, 2020, KNEE SURG RELAT RES, V32
[26]   Comparison of robotic-assisted and conventional manual implantation of a primary total knee arthroplasty [J].
Park, Sang Eun ;
Lee, Chun Taek .
JOURNAL OF ARTHROPLASTY, 2007, 22 (07) :1054-1059
[27]   Surgical Management of Osteoarthritis of the Knee [J].
Quinn, Robert H. ;
Murray, Jayson N. ;
Pezold, Ryan ;
Sevarino, Kaitlyn S. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2018, 26 (09) :E191-E193
[28]   Efficacy and reliability of active robotic-assisted total knee arthroplasty compared with conventional total knee arthroplasty: a systematic review and meta-analysis [J].
Ren, Yi ;
Cao, Shiliang ;
Wu, Jinxuan ;
Weng, Xisheng ;
Feng, Bin .
POSTGRADUATE MEDICAL JOURNAL, 2019, 95 (1121) :125-133
[29]   Mechanical alignment technique for TKA: Are there intrinsic technical limitations? [J].
Riviere, C. ;
Iranpour, F. ;
Auvinet, E. ;
Aframian, A. ;
Asare, K. ;
Harris, S. ;
Cobb, J. ;
Parratte, S. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (07) :1057-1067
[30]   A clinical review of robotic navigation in total knee arthroplasty: historical systems to modern design [J].
Siddiqi, Ahmed ;
Horan, Timothy ;
Molloy, Robert M. ;
Bloomfield, Michael R. ;
Patel, Preetesh D. ;
Piuzzi, Nicolas S. .
EFORT OPEN REVIEWS, 2021, 6 (04) :252-269