The Assessment of 24-Hr Physical Behavior in Children and Adolescents via Wearables: A Systematic Review of Laboratory Validation Studies

被引:1
作者
Giurgiu, Marco [1 ,2 ]
Nigg, Carina [1 ,3 ]
Fiedler, Janis [1 ]
Timm, Irina [1 ]
Rulf, Ellen [1 ]
Bussmann, Johannes B. J. [4 ]
Nigg, Claudio R. [5 ]
Woll, Alexander [1 ]
Ebner-Priemer, Ulrich W. [1 ,2 ]
机构
[1] Karlsruhe Inst Technol KIT, Dept Sports & Sports Sci, Karlsruhe, Germany
[2] Heidelberg Univ, Cent Inst Mental Hlth, Med Fac Mannheim, Dept Psychiat & Psychotherapy, Mannheim, Germany
[3] Univ Bern, Inst Sport Sci, Sport Pedag Dept, Bern, Switzerland
[4] Univ Med Ctr Rotterdam, Dept Rehabil Med, Erasmus MC, Rotterdam, Netherlands
[5] Univ Bern, Inst Sport Sci, Hlth Sci Dept, Bern, Switzerland
关键词
accelerometry; physical activity; sleep; sedentary behavior; SEDENTARY BEHAVIOR; ACTIVITY GUIDELINES; CALIBRATION; CHALLENGES; MONITORS; QUALITY; YOUTH; WRIST;
D O I
10.1123/]mpb.2022-0014
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: To raise attention to the quality of published validation protocols while comparing (in)consistencies and providing an overview on wearables, and whether they show promise or not. Methods: Searches from five electronic databases were included concerning the following eligibility criteria: (a) laboratory conditions with humans (<18 years), (b) device outcome must belong to one dimension of the 24-hr physical behavior construct (i.e., intensity, posture/activity type outcomes, biological state), (c) must include a criterion measure, and (d) published in a peer-reviewed English language journal between 1980 and 2021. Results: Out of 13,285 unique search results, 123 articles were included. In 86 studies, children <13 years were recruited, whereas in 26 studies adolescents (13-18 years) were recruited. Most studies (73.2%) validated an intensity outcome such as energy expenditure; only 20.3% and 13.8% of studies validated biological state or posture/activity type outcomes, respectively. We identified 14 wearables that had been used to validate outcomes from two or three different dimensions. Most (n = 72) of the identified 88 wearables were only validated once. Risk of bias assessment resulted in 7.3% of studies being classified as "low risk," 28.5% as "some concerns," and 71.5% as "high risk." Conclusion: Overall, laboratory validation studies of wearables are characterized by low methodological quality, large variability in design, and a focus on intensity. No identified wearable provides valid results across all three dimensions of the 24-hr physical behavior construct. Future research should more strongly aim at biological state and posture/activity type outcomes, and strive for standardized protocols embedded in a validation framework.
引用
收藏
页码:263 / 276
页数:14
相关论文
共 44 条
[1]   A Meta-analysis of the Relationship Between Children's Physical Activity and Mental Health [J].
Ahn, Soyeon ;
Fedewa, Alicia L. .
JOURNAL OF PEDIATRIC PSYCHOLOGY, 2011, 36 (04) :385-397
[2]   The SBSM Guide to Actigraphy Monitoring: Clinical and Research Applications [J].
Ancoli-Israel, Sonia ;
Martin, Jennifer L. ;
Blackwell, Terri ;
Buenaver, Luis ;
Liu, Lianqi ;
Meltzer, Lisa J. ;
Sadeh, Avi ;
Spira, Adam P. ;
Taylor, Daniel J. .
BEHAVIORAL SLEEP MEDICINE, 2015, 13 :S4-S38
[3]  
[Anonymous], 2019, WHO Guidelines on Physical Activity, Sedentary Behaviour for Children under 5 Years of Age
[4]   Physical Activity and Physical Self-Concept in Youth: Systematic Review and Meta-Analysis [J].
Babic, Mark J. ;
Morgan, Philip J. ;
Plotnikoff, Ronald C. ;
Lonsdale, Chris ;
White, Rhiannon L. ;
Lubans, David R. .
SPORTS MEDICINE, 2014, 44 (11) :1589-1601
[5]   Calibration and Validation of Wearable Monitors [J].
Bassett, David R., Jr. ;
Rowlands, Alex ;
Trost, Stewart G. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 :S32-S38
[6]   Pushing the Limits of Strength Training [J].
Burtscher, Johannes ;
Millet, Gregoire P. ;
Burtscher, Martin .
AMERICAN JOURNAL OF PREVENTIVE MEDICINE, 2023, 64 (01) :145-146
[7]   Assessing physical behavior through accelerometry - State of the science, best practices and future directions [J].
Burchartz, Alexander ;
Anedda, Bastian ;
Auerswald, Tina ;
Giurgiu, Marco ;
Hill, Holger ;
Ketelhut, Sascha ;
Kolb, Simon ;
Mall, Christoph ;
Manz, Kristin ;
Nigg, Claudio R. ;
Reichert, Markus ;
Sprengeler, Ole ;
Wunsch, Kathrin ;
Matthews, Charles E. .
PSYCHOLOGY OF SPORT AND EXERCISE, 2020, 49
[8]   Diagnostic test evaluation methodology: A systematic review of methods employed to evaluate diagnostic tests in the absence of gold standard - An update [J].
Chikere, Chinyereugo M. Umemneku ;
Wilson, Kevin ;
Graziadio, Sara ;
Vale, Luke ;
Allen, A. Joy .
PLOS ONE, 2019, 14 (10)
[9]   Validation of Accelerometer Wear and Nonwear Time Classification Algorithm [J].
Choi, Leena ;
Liu, Zhouwen ;
Matthews, Charles E. ;
Buchowski, Maciej S. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (02) :357-364
[10]   Wearable sensors enable personalized predictions of clinical laboratory measurements [J].
Dunn, Jessilyn ;
Kidzinski, Lukasz ;
Runge, Ryan ;
Witt, Daniel ;
Hicks, Jennifer L. ;
Schussler-Fiorenza Rose, Sophia Miryam ;
Li, Xiao ;
Bahmani, Amir ;
Delp, Scott L. ;
Hastie, Trevor ;
Snyder, Michael P. .
NATURE MEDICINE, 2021, 27 (06) :1105-+