Non-equilibrium overlapping grid method with two-phase porous media model for printed circuit heat exchanger based steam generator

被引:2
作者
Tang, Zicheng [1 ]
He, Song [1 ]
Li, Nianqi [1 ]
Zeng, Min [1 ]
Yan, Xiaohong [2 ]
Wang, Qiuwang [1 ]
Ma, Ting [1 ]
机构
[1] Xian Jiaotong Tong Univ, Key Lab Thermo Fluid Sci & Engn, Minist Educ, Xian 710049, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Environm & Chem Engn, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Printed circuit heat exchanger; Steam generator; Small modular reactor; Non-equilibrium overlapping grid method; Two-phase porous media model; DROPLET ENTRAINMENT; PRESSURE-DROP; MASS-TRANSFER; FLOW; CODE; SIMULATION;
D O I
10.1016/j.ijheatmasstransfer.2024.125960
中图分类号
O414.1 [热力学];
学科分类号
摘要
The printed circuit heat exchanger (PCHE) is a promising alternative for the once-through steam generator (OTSG) of small modular reactors due to its compact structure and high efficiency. To study the effect of flow maldistribution on the performance of heat transfer and thermal stress, it is necessary to conduct threedimensional full-scale simulation of two-side fluid and solid domains in the printed circuit heat exchanger based steam genarator (PCHESG). However, there is a lack of mature thermal-hydraulic models for the PCHESG. This work proposes a non-equilibrium overlapping grid method with two-phase porous media model for the PCHESG. The temperature and flow fields of the PCHESG under high-pressure conditions are evaluated. Compared to traditional methods, the new method greatly reduces the order of magnitude of the grid number from 107 109 to 106 and the computational time from days to hours. It is found that the flow maldistribution with a threshold cold-side mass flow rate of 0.08 0.0944 kg/s induced by the header parts of the PCHESG deteriorates the total heat transfer rate by 58.8 % and increases the spatial non-uniformity of the temperature and phase distributions. The solid domain is solved simultaneously and its temperature non-uniformity becomes significant with a threshold cold-side mass flow rate of 0.04 0.06 kg/s. The results demonstrate that this method has great potential in achieving rapid design and optimization for the PCHESG.
引用
收藏
页数:21
相关论文
共 45 条
[1]  
ANSYS Inc, 2020, Ansys Fluent Theory Guide
[2]   Droplet entrainment and deposition rates in a horizontal annular flow for SPACE code [J].
Bae, Byeonggeon ;
Kim, Taeho ;
Jeong, Jaejun ;
Kim, Kyungdoo ;
Yun, Byongjo .
PROGRESS IN NUCLEAR ENERGY, 2018, 109 :45-52
[3]   Experimental investigation of flow boiling heat transfer and instabilities in straight microchannels [J].
Balasubramanian, K. ;
Jagirdar, M. ;
Lee, P. S. ;
Teo, C. J. ;
Chou, S. K. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 66 :655-671
[4]   3-D numerical study of subcooled flow boiling in a horizontal rectangular mini-channel by VOSET [J].
Chen, Yu-Jie ;
Ling, Kong ;
Ding, Hao ;
Wang, Yun ;
Jin, Shu-Qi ;
Tao, Wen-Quan .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 183
[5]   Thermal-hydraulic performance of a PCHE with sodium and sCO2 as working fluids [J].
Cong, Tenglong ;
Wang, Zhenhong ;
Zhang, Rui ;
Wang, Bicheng ;
Zhu, Yanming .
ANNALS OF NUCLEAR ENERGY, 2021, 157
[6]   Study on secondary side flow of steam generator with coupled heat transfer from primary to secondary side [J].
Cong, Tenglong ;
Tian, Wenxi ;
Qiu, Suizheng ;
Su, Guanghui .
APPLIED THERMAL ENGINEERING, 2013, 61 (02) :519-530
[7]   A novel interphase mass transfer model toward the VOF simulation of subcooled flow boiling [J].
Dong, Fei ;
Wang, Zhiming ;
Cao, Taotao ;
Ni, Jie .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2019, 76 (04) :220-231
[8]   CFD analysis andheat transfer characteristics of printed circuit heat exchanger [J].
El-Hakim, N. ;
Assaf, J. ;
Nehme, B. ;
Zeghondy, B. ;
Said, W. ;
Jelwan, J. .
JOURNAL OF THERMAL ENGINEERING, 2022, 8 (03) :335-348
[9]  
GNIELINSKI V, 1976, INT CHEM ENG, V16, P359
[10]  
GUNGOR KE, 1987, CHEM ENG RES DES, V65, P148