Low-dose phase contrast mammography with conventional x-ray sources

被引:86
|
作者
Olivo, A. [1 ]
Gkoumas, S. [1 ]
Endrizzi, M. [1 ]
Hagen, C. K. [1 ]
Szafraniec, M. B. [1 ]
Diemoz, P. C. [1 ]
Munro, P. R. T. [2 ,3 ]
Ignatyev, K. [4 ]
Johnson, B. [5 ]
Horrocks, J. A. [5 ]
Vinnicombe, S. J. [6 ]
Jones, J. L. [7 ]
Speller, R. D. [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
[2] Univ Western Australia, Sch Elect Elect & Comp Engn, Opt & Biomed Engn Lab, Crawley, WA 6009, Australia
[3] Univ Western Australia, Ctr Microscopy Characterizat & Anal, Crawley, WA 6009, Australia
[4] Diamond Light Source, Didcot OX11 0DE, Oxon, England
[5] Barts Hlth NHS Trust, St Bartholomews Hosp, London EC1A 7BE, England
[6] Univ Dundee, Med Res Inst, Div Canc Res, Dundee DD1 9SY, Scotland
[7] Univ London, John Vane Sci Ctr, Ctr Tumour Biol, London EC1M 6BQ, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
mammography; x-ray phase contrast imaging; microcalcifications; image contrast; FIELD DIGITAL MAMMOGRAPHY; SYNCHROTRON-RADIATION; RETRIEVAL;
D O I
10.1118/1.4817480
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To provide an x-ray phase contrast imaging (XPCI) method working with conventional sources that could be readily translated into clinical practice. XPCI shows potential in synchrotron studies but attempts at translating it for use with conventional sources are subject to limitations in terms of field of view, stability, exposure time, and possibly most importantly, delivered dose. Methods: Following the adaptation of our "edge-illumination" XPCI technique for use with conventional x-ray sources through the use of x-ray masks, the authors have further modified the design of such masks to allow further reducing the dose delivered to the sample without affecting the phase sensitivity of the method. Results: The authors have built a prototype based on the new mask design and used it to image ex vivo breast tissue samples containing malignant lesions. The authors compared images acquired with this prototype to those obtained with a conventional system. The authors demonstrate and quantify image improvements, especially in terms of microcalcification detection. On calcifications detected also by the conventional system, the authors measure contrast increases from five to nine fold; calcifications and other features were also detected which are completely invisible in the conventional image. Dose measurements confirmed that the above enhancements were achieved while delivering doses compatible with clinical practice. Conclusions: The authors obtained phase-related image enhancements in mammography by means of a system built with components available off-the-shelf that operates under exposure time and dose conditions compatible with clinical practice. This opens the way to a straightforward translation of phase enhanced imaging methods into clinical practice. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] X-ray phase-contrast imaging: the quantum perspective
    Slowik, J. M.
    Santra, R.
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2013, 46 (16)
  • [42] Statistical Properties of X-Ray Phase-Contrast Tomography
    Chou, Cheng-Ying
    Anastasio, Mark A.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 6648 - +
  • [43] Fluence adaptation for contrast-based dose optimization in x-ray phase-contrast imaging
    Wu, Chengpeng
    Xing, Yuxiang
    Zhang, Li
    Chen, Zhiqiang
    Zhu, Xiaohua
    Zhang, Xi
    Gao, Hewei
    MEDICAL PHYSICS, 2021, 48 (10) : 6106 - 6120
  • [44] X-ray phase-contrast imaging with polychromatic sources and the concept of effective energy
    Munro, Peter R. T.
    Olivo, Alessandro
    PHYSICAL REVIEW A, 2013, 87 (05):
  • [45] Advantages of quasi-monochromatic X-ray sources in absorption mammography
    Oliva, P.
    Golosio, B.
    Stumbo, S.
    Carpinelli, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 608 (01) : S106 - S108
  • [46] Robustness of phase retrieval methods in x-ray phase contrast imaging: A comparison
    Yan, Aimin
    Wu, Xizeng
    Liu, Hong
    MEDICAL PHYSICS, 2011, 38 (09) : 5073 - 5080
  • [47] Dose and detectability improvements with high energy phase sensitive x-ray imaging in comparison to low energy conventional imaging
    Wong, Molly Donovan
    Yan, Aimin
    Ghani, Muhammad
    Li, Yuhua
    Fajardo, Laurie
    Wu, Xizeng
    Liu, Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (09) : N37 - N48
  • [48] Fabrication of absorption gratings with X-ray lithography for X-ray phase contrast imaging
    Wang, Bo
    Wang, Yu-Ting
    Yi, Fu-Ting
    Zhang, Tian-Chong
    liu, Jing
    Zhou, Yue
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2018, 32 (13):
  • [49] Elimination of gridlines in X-ray imaging for mammography
    Maruyama, Toshinori
    Yamamoto, Hideki
    IST 2006: PROCEEDINGS OF THE 2006 IEEE INTERNATIONAL WORKSHOP ON IMAGING SYSTEMS AND TECHNIQUES, 2006, : 103 - +
  • [50] Reduction of scattered radiation dose by X-ray shielding during mammography
    Koo, Bon-Yeoul
    Lee, Kwang-Sung
    RADIATION PHYSICS AND CHEMISTRY, 2020, 177