Low-dose phase contrast mammography with conventional x-ray sources

被引:86
|
作者
Olivo, A. [1 ]
Gkoumas, S. [1 ]
Endrizzi, M. [1 ]
Hagen, C. K. [1 ]
Szafraniec, M. B. [1 ]
Diemoz, P. C. [1 ]
Munro, P. R. T. [2 ,3 ]
Ignatyev, K. [4 ]
Johnson, B. [5 ]
Horrocks, J. A. [5 ]
Vinnicombe, S. J. [6 ]
Jones, J. L. [7 ]
Speller, R. D. [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
[2] Univ Western Australia, Sch Elect Elect & Comp Engn, Opt & Biomed Engn Lab, Crawley, WA 6009, Australia
[3] Univ Western Australia, Ctr Microscopy Characterizat & Anal, Crawley, WA 6009, Australia
[4] Diamond Light Source, Didcot OX11 0DE, Oxon, England
[5] Barts Hlth NHS Trust, St Bartholomews Hosp, London EC1A 7BE, England
[6] Univ Dundee, Med Res Inst, Div Canc Res, Dundee DD1 9SY, Scotland
[7] Univ London, John Vane Sci Ctr, Ctr Tumour Biol, London EC1M 6BQ, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
mammography; x-ray phase contrast imaging; microcalcifications; image contrast; FIELD DIGITAL MAMMOGRAPHY; SYNCHROTRON-RADIATION; RETRIEVAL;
D O I
10.1118/1.4817480
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To provide an x-ray phase contrast imaging (XPCI) method working with conventional sources that could be readily translated into clinical practice. XPCI shows potential in synchrotron studies but attempts at translating it for use with conventional sources are subject to limitations in terms of field of view, stability, exposure time, and possibly most importantly, delivered dose. Methods: Following the adaptation of our "edge-illumination" XPCI technique for use with conventional x-ray sources through the use of x-ray masks, the authors have further modified the design of such masks to allow further reducing the dose delivered to the sample without affecting the phase sensitivity of the method. Results: The authors have built a prototype based on the new mask design and used it to image ex vivo breast tissue samples containing malignant lesions. The authors compared images acquired with this prototype to those obtained with a conventional system. The authors demonstrate and quantify image improvements, especially in terms of microcalcification detection. On calcifications detected also by the conventional system, the authors measure contrast increases from five to nine fold; calcifications and other features were also detected which are completely invisible in the conventional image. Dose measurements confirmed that the above enhancements were achieved while delivering doses compatible with clinical practice. Conclusions: The authors obtained phase-related image enhancements in mammography by means of a system built with components available off-the-shelf that operates under exposure time and dose conditions compatible with clinical practice. This opens the way to a straightforward translation of phase enhanced imaging methods into clinical practice. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Simultaneous implementation of low dose and high sensitivity capabilities in differential phase contrast and dark-field imaging with laboratory x-ray sources
    Olivo, A.
    Hagen, C. K.
    Millard, T. P.
    Vittoria, F.
    Diemoz, P. C.
    Endrizzi, M.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [32] Phase-contrast X-ray imaging of breast
    Keyrilainen, Jani
    Bravin, Alberto
    Fernandez, Manuel
    Tenhunen, Mikko
    Virkkunen, Pekka
    Suortti, Pekka
    ACTA RADIOLOGICA, 2010, 51 (08) : 866 - 884
  • [33] Conical slit and conventional X-ray sources: Challenging steps for calcium spots detection
    Fioreze, M.
    Cusatis, C.
    Keister, J. W.
    Honnicke, M. G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 867 : 171 - 181
  • [34] An integral phase contrast modulation transfer function for X-ray phase contrast imaging
    Wu, Jie
    Chen, Jiabi
    OPTIK, 2013, 124 (17): : 2583 - 2586
  • [35] Contrast enhancement in X-ray phase contrast tomography
    Pan, Adam
    Xu, Ling
    Petruccelli, Jon C.
    Gupta, Rajiv
    Singh, Bipin
    Barbastathis, George
    OPTICS EXPRESS, 2014, 22 (15): : 18020 - 18026
  • [36] CT dose reduction factors in the thousands using X-ray phase contrast
    Kitchen, Marcus J.
    Buckley, Genevieve A.
    Gureyev, Timur E.
    Wallace, Megan J.
    Andres-Thio, Nico
    Uesugi, Kentaro
    Yagi, Naoto
    Hooper, Stuart B.
    SCIENTIFIC REPORTS, 2017, 7
  • [37] Choosing sensitivity to reduce X-ray dose in medical phase contrast imaging
    Preusche, Oliver
    OPTICS EXPRESS, 2018, 26 (08): : 10339 - 10357
  • [38] Improving spatial resolution with an edge-enhancement model for low-dose propagation-based X-ray phase-contrast computed tomography
    Zhang, Lin
    Zhao, Huijuan
    Zhou, Zhongxing
    Jia, Mengyu
    Zhang, Limin
    Jiang, Jingying
    Gao, Feng
    OPTICS EXPRESS, 2021, 29 (23): : 37399 - 37417
  • [39] Low-dose quantitative phase contrast medical CT
    Mittone, A.
    Bravin, A.
    Coan, P.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (02)
  • [40] Low-dose phase-based X-ray imaging techniques for in situ soft tissue engineering assessments
    Izadifar, Zohreh
    Honaramooz, Ali
    Wiebe, Sheldon
    Belev, George
    Chen, Xiongbiao
    Chapman, Dean
    BIOMATERIALS, 2016, 82 : 151 - 167