Determination of sodium cyclamate in Baijiu by pre-column derivatization-high performance liquid chromatography with fluorometric detection

被引:0
作者
Gu, Changyu [1 ]
Li, Xiaobin [1 ]
Chai, Xiao [1 ]
Wang, Zhen [1 ]
Hou, Chenyu [1 ]
Ke, Runhui [1 ,2 ]
机构
[1] Sinolight Inspect & Certificat Co Ltd, Beijing 100016, Peoples R China
[2] China Natl Res Inst Food & Fermentat Ind Co Ltd, Beijing 100015, Peoples R China
关键词
high performance liquid chromatography ( HPLC ); fluorescence detection; pre-column derivatization; sodium cyclamate; Baijiu; FOODS;
D O I
10.3724/SP.J.1123.2023.10016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sodium cyclamate in Baijiu is a key item in the China National Food Safety Supervision and Inspection Plan. A simple, economical, sensitive, and reliable method is urgently needed for routine analysis and internal quality control. A method based on high performance liquid chromatography with fluorescence detection ( HPLC-FLD ) was developed for the determination of sodium cyclamate in Baijiu by o -phthalaldehyde derivatization. First, the sodium cyclamate in the sample solution was converted into amino compounds using the desulfurization reaction under acidic conditions. Next, 400 g/ L sodium hydroxide solution was added to the sample so- lution for neutralization. The amino compounds in the sample solution were then derivatized with o -phthalaldehyde to produce indole-substituted derivatives that are capable of producing fluorescence signals. Separation was carried out on a C18 18 column (250 mmx4. 6 mm, 5 mu m ) in isocratic elution mode using a mobile phase consisting of acetonitrile and phosphate buffer. Finally, the eluate was monitored using a fluorescence detector, and an external standard method was used for quantification. A good linear relationship was obtained in the range of 0. 1- 2. 0 mg/ L, with correlation coefficients greater than 0.999. The average recoveries of sodium cyclamate spiked at levels of 0.1-1.0 mg/kg in Baijiu samples ranged from 90. 7% to 100.9%, with relative standard deviations ( RSDs ) of 3.5%-5.6% ( n = 6). The limits of detection and quantification were 0.03 and 0. 10 mg/ kg, respectively. Nine Baijiu samples collected from the market were tested, and the results demonstrated that the contents of sodium cyclamate detected by the developed method were consistent with those obtained using the liquid chromatography- tandem mass spectrometry ( LC-MS/ MS ) method described in GB 5009.97-2016 (the third method). ). The proposed method is economical, sensitive, specific, and accurate; ; thus, it pro- vides a basic approach for the determination of sodium cyclamate in Baijiu samples and has great potential for routine analysis in foodstuffs.
引用
收藏
页码:792 / 798
页数:7
相关论文
共 24 条
  • [11] Interaction studies of sodium cyclamate with DNA revealed by spectroscopy methods
    Hu, Yong
    Xie, Meiyi
    Wu, Xiaoyong
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 220
  • [12] Ultrasensitive and simultaneous determination of twenty-one amino acids and amines in culture media, red wine and beer
    Hu, Zhongqiu
    Li, Lin
    Yuan, Yahong
    Yue, Tianli
    [J]. FOOD CHEMISTRY, 2014, 158 : 56 - 65
  • [13] On-cartridge derivatisation using matrix solid phase dispersion for the determination of cyclamate in foods
    Li, Jianjun
    Liu, Yun
    Liu, Qianping
    Hui, Junfeng
    Liu, Yangzi
    [J]. ANALYTICA CHIMICA ACTA, 2017, 972 : 46 - 53
  • [14] Liu G, 2017, Food Science and Technology, V42, P300
  • [15] Liu X Y, 2021, China Food Safety Magazine, P44
  • [16] Mortensen A., 2006, Scandinavian Journal of Food & Nutrition, V50, P104, DOI 10.1080/17482970600982719
  • [17] Sun H, 2018, Liquor Making, V45, P93
  • [18] Sun L, 2023, The Food Industry, V44, P300
  • [19] [汪建飞 Wang Jianfei], 2022, [化学研究与应用, Chemical Research and Application], V34, P909
  • [20] Wu B Q, 1994, Liaoning Chemical Industry, P38