Early detection of deteriorating patients in general wards through continuous contactless vital signs monitoring

被引:2
作者
Yadav, Ambuj [1 ]
Dandu, Himanshu [1 ]
Parchani, Gaurav [2 ]
Chokalingam, Kumar [2 ]
Kadambi, Pooja [2 ]
Mishra, Rajesh [2 ]
Jahan, Ahsina [2 ]
Teboul, Jean-Louis [3 ]
Latour, Jos M. [4 ]
机构
[1] King Georges Med Univ, Dept Med, Lucknow, India
[2] Turtle Shell Technol Pvt Ltd, Dept Clin Res, Bengaluru, India
[3] Paris Saclay Univ, Paris Saclay Med Sch, Le Kremlin Bicetre, France
[4] Univ Plymouth, Fac Hlth, Plymouth, England
来源
FRONTIERS IN MEDICAL TECHNOLOGY | 2024年 / 6卷
关键词
Early Warning System (EWS); remote; contactless; continuous; monitoring; general ward; ballistocardiography; HEALTH-CARE WORKERS; SHORTAGE; RISK; UNIT;
D O I
10.3389/fmedt.2024.1436034
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective To assess the efficacy of continuous contactless vital signs monitoring with an automated Early Warning System (EWS) in detecting clinical deterioration among patients in general wards.Methods A prospective observational cohort study was conducted in the medical unit of a tertiary care hospital in India, involving 706 patients over 84,448 monitoring hours. The study used a contactless ballistocardiography system (Dozee system) to continuously monitor heart rate, respiratory rate, and blood pressure. The study assessed total, mean, and median alerts at 24, 48, 72, 96, 120 h, and length of stay (LOS) before patient deterioration or discharge. It analyzed alert sensitivity and specificity, average time from initial alert to deterioration, and healthcare practitioners (HCP) activity. Study was registered with the Clinical Trials Registry-India CTRI/2022/10/046404.Results Out of 706 patients, 33 (5%) experienced clinical deterioration, while 673 (95%) did not. The deterioration group consistently had a higher number of alerts compared to those who were discharged normally, across all time-points. On average, the time between the initial alert and clinical deterioration was 16 h within the last 24 h preceding the event. The sensitivity of the Dozee-EWS varied between 67% and 94%. HCP spend 10% of their time on vital signs check and documentation.Conclusions This study suggests that utilizing contactless continuous vital signs monitoring with Dozee-EWS in general ward holds promise for enhancing the early detection of clinical deterioration. Further research is essential to evaluate the effectiveness across a wider range of clinical settings.
引用
收藏
页数:9
相关论文
共 49 条
  • [11] Wireless monitoring and real-time adaptive predictive indicator of deterioration
    Duncan, Heather P.
    Fule, Balazs
    Rice, Iain
    Sitch, Alice J.
    Lowe, David
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [12] Effect of continuous wireless vital sign monitoring on unplanned ICU admissions and rapid response team calls: a before-and-after study
    Eddahchouri, Yassin
    Peelen, Roel, V
    Koeneman, Mats
    Touw, Hugo R. W.
    van Goor, Harry
    Bredie, Sebastian J. H.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2022, 128 (05) : 857 - 863
  • [13] Technical considerations for evaluating clinical prediction indices: a case study for predicting code blue events with MEWS
    Gadhoumi, Kais
    Beltran, Alex
    Scully, Christopher G.
    Xiao, Ran
    Nahmias, David O.
    Hu, Xiao
    [J]. PHYSIOLOGICAL MEASUREMENT, 2021, 42 (05)
  • [14] Description of vital signs data measurement frequency in a medical/surgical unit at a community hospital in United States
    Ghosh, Erina
    Eshelman, Larry
    Yang, Lin
    Carlson, Eric
    Lord, Bill
    [J]. DATA IN BRIEF, 2018, 16 : 612 - 616
  • [15] Continuous monitoring is superior to manual measurements in detecting vital sign deviations in patients with COVID-19
    Gronbaek, Katja Kjaer
    Rasmussen, Soren Moller
    Langer, Natasha Hemicke
    Vincentz, Mette
    Oxboll, Anne-Britt
    Sogaard, Marlene
    Awada, Hussein Nasser
    Jensen, Tomas O.
    Jensen, Magnus Thorsten
    Sorensen, Helge B. D.
    Aasvang, Eske Kvanner
    Meyhoff, Christian Sylvest
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2023, 67 (05) : 640 - 648
  • [16] A pilot study to investigate real-time digital alerting from wearable sensors in surgical patients
    Joshi, Meera
    Ashrafian, Hutan
    Arora, Sonal
    Sharabiani, Mansour
    McAndrew, Kenny
    Khan, Sadia N.
    Cooke, Graham S.
    Darzi, Ara
    [J]. PILOT AND FEASIBILITY STUDIES, 2022, 8 (01)
  • [17] CLINICAL VALIDATION OF AN INDIGENEOUS MICRO-VIBRATION VITAL PARAMETER MONITOR DOZEE VS
    Kedia, Swarna
    Rahman, Inam Ur
    Kaushal, Ashish
    Mahizhvannan, E.
    Jain, Rishabh Shamra
    Radhakrishna, Rachna
    Rao, Srishti
    Chokalingam, Kumar
    Rawooth, Madhusmita
    Kadambi, Pooja
    Parchani, Gaurav
    [J]. 2023 15TH INTERNATIONAL CONFERENCE ON COMMUNICATION SYSTEMS & NETWORKS, COMSNETS, 2023,
  • [18] Automated continuous noninvasive ward monitoring: future directions and challenges
    Khanna, Ashish K.
    Hoppe, Phillip
    Saugel, Bernd
    [J]. CRITICAL CARE, 2019, 23
  • [19] Monitoring in the Intensive Care
    Kipnis, Eric
    Ramsingh, Davinder
    Bhargava, Maneesh
    Dincer, Erhan
    Cannesson, Maxime
    Broccard, Alain
    Vallet, Benoit
    Bendjelid, Karim
    Thibault, Ronan
    [J]. CRITICAL CARE RESEARCH AND PRACTICE, 2012, 2012
  • [20] If early warning systems are used, would it be possible to estimate early clinical deterioration risk and prevent readmission to intensive care?
    Kupeli, I
    Subasi, F.
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2021, 24 (12) : 1773 - 1778