A comparative analysis of preclinical computed tomography radiomics using cone-beam and micro-computed tomography scanners

被引:0
作者
Brown, Kathryn H. [1 ]
Kerr, Brianna N. [1 ]
Pettigrew, Mihaela [1 ]
Connor, Kate [2 ,3 ]
Miller, Ian S. [2 ,3 ,4 ]
Shiels, Liam [2 ,3 ]
Connolly, Colum [2 ,3 ]
Mcgarry, Conor K. [1 ,5 ]
Byrne, Annette T. [2 ,3 ,4 ]
Butterworth, Karl T. [1 ]
机构
[1] Queens Univ Belfast, Patrick G Johnston Ctr Canc Res, Belfast, North Ireland
[2] Royal Coll Surgeons Ireland, Dept Physiol & Med Phys, Dublin, Ireland
[3] Royal Coll Surgeons Ireland, Ctr Syst Med, Dublin, Ireland
[4] Royal Coll Surgeons Ireland, Natl Preclin Imaging Ctr, Dublin, Ireland
[5] Belfast Hlth & Social Care Trust, Northern Ireland Canc Ctr, Belfast, North Ireland
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2024年 / 31卷
基金
爱尔兰科学基金会; 英国国家替代、减少和改良动物研究中心;
关键词
Radiomics; Preclinical; Computed tomography; Cone-beam; Micro; Phantom; Tissue density; Reliability; FEATURE STABILITY; CT; FEATURES; IMAGES; IMPACT; HEAD;
D O I
10.1016/j.phro.2024.100615
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Radiomics analysis extracts quantitative data (features) from medical images. These features could potentially reflect biological characteristics and act as imaging biomarkers within precision medicine. However, there is a lack of cross-comparison and validation of radiomics outputs which is paramount for clinical implementation. In this study, we compared radiomics outputs across two computed tomography (CT)-based preclinical scanners. Materials and methods: Cone beam CT (CBCT) and mu CT scans were acquired using different preclinical CT imaging platforms. The reproducibility of radiomics features on each scanner was assessed using a phantom across imaging energies (40 & 60 kVp) and segmentation volumes (44-238 mm(3)). Retrospective mouse scans were used to compare feature reliability across varying tissue densities (lung, heart, bone), scanners and after voxel size harmonisation. Reliable features had an intraclass correlation coefficient (ICC) > 0.8. Results: First order and GLCM features were the most reliable on both scanners across different volumes. There was an inverse relationship between tissue density and feature reliability, with the highest number of features in lung (CBCT=580, =580, mu CT=734) =734) and lowest in bone (CBCT=110, =110, mu CT=560). =560). Comparable features for lung and heart tissues increased when voxel sizes were harmonised. We have identified tissue-specific preclinical radiomics signatures in mice for the lung (133), heart (35), and bone (15). Conclusions: Preclinical CBCT and mu CT scans can be used for radiomics analysis to support the development of meaningful radiomics signatures. This study demonstrates the importance of standardisation and emphasises the need for multi-centre studies.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Evaluation of maxillary trabecular microstructure as an indicator of implant stability by using 2 cone beam computed tomography systems and micro-computed tomography
    Kulah, Kivanc
    Gulsahi, Ayse
    Kamburoglu, Kivanc
    Geneci, Ferhat
    Ocak, Mert
    Celik, H. Hamdi
    Ozen, Tuncer
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2019, 127 (03): : 247 - 256
  • [22] Comparison of Cone-Beam Computed Tomography and Multislice Computed Tomography in the Assessment of Extremity Fractures
    Dubreuil, Thibaut
    Mouly, Jerome
    Ltaief-Boudrigua, Aicha
    Martinon, Amanda
    Tilhet-Coartet, Stephane
    Tazarourte, Karim
    Pialat, Jean-Baptiste
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (03) : 372 - 378
  • [23] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Niccolò Faccioli
    Giovanni Foti
    Marco Barillari
    Andrea Atzei
    Roberto Pozzi Mucelli
    Skeletal Radiology, 2010, 39 : 1087 - 1095
  • [24] Imaging of mandible invasion by oral squamous cell carcinoma using computed tomography, cone-beam computed tomography and bone scintigraphy with SPECT
    Hakim, Samer G.
    Wieker, Henning
    Trenkle, Thomas
    Sieg, Peter
    Konitzer, Jens
    Holl-Ulrich, Konstanze
    Jacobsen, Hans-Christian
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (03) : 961 - 967
  • [25] Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners
    Suomalainen, A.
    Kiljunen, T.
    Kaser, Y.
    Peltola, J.
    Kortesniemi, M.
    DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (06) : 367 - 378
  • [26] Reliability of cone-beam computed tomography for temporomandibular joint analysis
    Gorucu-Coskuner, Hande
    Atik, Ezgi
    El, Hakan
    KOREAN JOURNAL OF ORTHODONTICS, 2019, 49 (02) : 81 - 88
  • [27] Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography
    Chau, Anson C. M.
    Fung, Karl
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (04): : 559 - 565
  • [28] Comparison of cone-beam computed tomography with multislice computed tomography in detection of small osseous condylar defects
    Jones, Elizabeth M.
    Papio, Melissa
    Tee, Boon Ching
    Beck, Frank M.
    Fields, Henry W.
    Sun, Zongyang
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2016, 150 (01) : 130 - 139
  • [29] DOSIMETRIC STUDY OF MANDIBLE EXAMINATIONS PERFORMED WITH THREE CONE-BEAM COMPUTED TOMOGRAPHY SCANNERS
    Khoury, Helen J.
    Andrade, Marcos E.
    Araujo, Max Well
    Brasileiro, Izabela V.
    Kramer, Richard
    Huda, Amir
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 162 - 165
  • [30] Hybrid simulation of scatter intensity in industrial cone-beam computed tomography
    Thierry, R.
    Miceli, A.
    Hofmann, J.
    Flisch, A.
    Sennhauser, U.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (02) : 611 - 619