Relationship between the polymerization distance of monowave and polywave light-curing units and the irradiance and physical properties of dental resin-based composites

被引:1
作者
Ruiz-Penarrieta, Madelin [1 ]
Moyaho-Bernal, Maria de los Angeles [1 ]
Salazar-Vergara, Jose A. [1 ]
Ortega, Juana P. Ramirez [2 ]
de la Rosa, Laura E. Serrano [3 ]
Rodriguez-Chavez, Jacqueline A. [4 ]
Flores-Ledesma, Abigailt [1 ]
机构
[1] Meritorious Autonomous Univ Puebla, Fac Stomatol, Dent Mat & Biomat Lab, Calle 31 Poniente 1304,Colonia Volcanes, Puebla 72410, Mexico
[2] Univ Nacl Autonoma Mexico, Fac Dent, Postgrad Studies & Res Div, Dent Mat & Biomat Res Lab, Mexico City, Mexico
[3] Meritorious Autonomous Univ Puebla, Phys Inst, Puebla, Mexico
[4] Univ Guadalajara, Univ Ctr Hlth Sci, Dept Integral Dent Clin, Guadalajara, Mexico
关键词
depth of cure; flexural strength; irradiance; light curing unit; resin-based composite; PULP CHAMBER; HEAT DEVELOPMENT; BULK-FILL; TEMPERATURE; CONVERSION; INTENSITY;
D O I
10.2334/josnusd.24-0045
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the influence of the polymerization distance of monowave and polywave light curing units (LCUs) on the measured irradiance relative to the value reported by the manufacturer in relation to the physical properties of resin-based composites (RBCs). Methods: Four LCUs were used: one monowave and three polywave. The irradiance was measured with a digital radiometer. Depth of cure (DC) and flexural strength (FS) tests were performed according to ISO 4049:2019 at polymerization distances of 0 mm and 5 mm. Results: The irradiance of all LCUs was higher than that reported by the manufacturer (>25-64%). The irradiance of the four LCUs was reduced when polymerization was performed at between 0 to 5 mm (paired t-test, P < 0.001). The DC at 0 mm was similar in all groups but was significantly decreased at 5 mm distance (ANOVA P < 0.001). FS showed differences among the LCUs at 0 mm (ANOVA P < 0.001) and was affected by the polymerization distance. The elastic modulus was unaffected by the LCU used or the distance (ANOVA P > 0.001). Conclusions: The LCU must be positioned as near as possible to RBCs during the polymerization process, as increased distance negatively affects the depth of cure and flexural strength.
引用
收藏
页码:182 / 188
页数:7
相关论文
共 40 条
[1]   The Effect of Different Light Curing Units and Tip Distances on Translucency Parameters of Bulk fill Materials [J].
Al-Senan, Dana ;
Al-Nahedh, Hend .
SAUDI DENTAL JOURNAL, 2022, 34 (05) :362-368
[2]  
Alkhudhairy Fahad, 2017, J Contemp Dent Pract, V18, P39, DOI 10.5005/jp-journals-10024-1985
[3]   Nanofilled Resin Composite Properties and Clinical Performance: A Review [J].
Alzraikat, H. ;
Burrow, M. F. ;
Maghaireh, G. A. ;
Taha, N. A. .
OPERATIVE DENTISTRY, 2018, 43 (04) :E173-E190
[4]   Variation of depth of cure and intensity with distance using LED curing lights [J].
Aravamudhan, Krishna ;
Rakowski, Duane ;
Fan, P. L. .
DENTAL MATERIALS, 2006, 22 (11) :988-994
[5]   Effect of different curing times and distances on the microhardness of nanofilled resin-based composite restoration polymerized with high-intensity LED light curing units [J].
Barakah, Haifa .
SAUDI DENTAL JOURNAL, 2021, 33 (08) :1035-1041
[6]  
Beolchi RS, 2015, BRAZ ORAL RES, V29
[7]   Evaluation of color stability and microhardness of contemporary bulk-fill composite resins with different polymerization properties [J].
Can, Dilber Bilgili ;
Ozarslan, Merve .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (06) :924-932
[8]   Influence of Cavity Preparation, Light-curing Units, and Composite Filling on Intrapulpal Temperature Increase in an In Vitro Tooth Model [J].
Choi, S. H. ;
Roulet, J. F. ;
Heintze, S. D. ;
Park, S. H. .
OPERATIVE DENTISTRY, 2014, 39 (05) :E195-E205
[9]   Odontological light-emitting diode light-curing unit beam quality [J].
de Magalhaes Filho, Thales Ribeiro ;
Weig, Karin de Mello ;
Werneck, Marcelo Martins ;
da Costa Neto, Celio Albano ;
da Costa, Marysilvia Ferreira .
JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (05)
[10]  
Faria-e-Silva André L., 2017, Braz. Dent. J., V28, P632, DOI [10.1590/0103-6440201701727, 10.1590/0103-6440201701727]