Molecular Diagnostic Yield and Safety Profile of Ultrasound-Guided Lung Biopsies: A Cross-Sectional Study

被引:0
作者
D'Agnano, Vito [1 ,2 ]
Perrotta, Fabio [1 ,2 ]
Stella, Giulia Maria [3 ]
Pagliaro, Raffaella [1 ,2 ]
De Rosa, Filippo [4 ]
Cerqua, Francesco Saverio [2 ]
Schiattarella, Angela [1 ,2 ]
Grella, Edoardo [1 ]
Masi, Umberto [1 ]
Panico, Luigi [4 ]
Bianco, Andrea [1 ,2 ]
Iadevaia, Carlo [2 ]
机构
[1] Univ Campania L Vanvitelli, Dept Translat Med Sci, I-80131 Naples, Italy
[2] AO Colli, Monaldi Hosp, UOC Clin Pneumolog L Vanvitelli, I-80131 Naples, Italy
[3] Univ Pavia, IRCCS Policlin San Matteo Fdn, Med Sch, Dept Med Sci & Infect Dis,Unit Resp Dis, I-27100 Pavia, Italy
[4] AO Colli, Monaldi Hosp, Unit Pathol, I-80131 Naples, Italy
关键词
lung cancer; ultrasound; biopsy; diagnosis; pathology; PD-L1; targeted therapy; TRANSBRONCHIAL NEEDLE ASPIRATION; LESIONS; CANCER;
D O I
10.3390/cancers16162860
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary An ultrasound-guided percutaneous lung biopsy performed by a pulmonologist is a safe, minimally invasive procedure for patients with suspected lung malignancies, providing an excellent diagnostic yield for a comprehensive molecular profiling and programmed death ligand 1 testing. Moreover, ultrasound-guided percutaneous lung biopsy may represent a successful approach for diagnosis of lung lymphoid lesions, with potential implication on reducing time-to-treatment time.Abstract Background: The recent advances in precision oncology for lung cancer treatment has focused attention on the importance of obtaining appropriate specimens for tissue diagnosis as well as comprehensive molecular profiling. CT scan-guided biopsies and bronchoscopy are currently the main procedures employed for tissue sampling. However, growing evidence suggests that ultrasound-guided biopsies may represent an effective as well as safe approach in this diagnostic area. This study explores the safety and the diagnostic yield for cancer molecular profiling in ultrasound-guided percutaneous lung lesion biopsies (US-PLLB). Methods: One hundred consecutive patients with suspected lung cancer, between January 2021 and May 2024, who had ultrasound-guided lung biopsies have been retrospectively analyzed. Molecular profiling was conducted with next-generation sequencing Genexus using Oncomine precision assay or polymerase chain reaction according to specimen quality. Qualitative immunohistochemical assay of programmed death ligand 1 (PD-L1) expression was evaluated by the Dako PD-L1 immunohistochemistry 22C3 pharmDx assay. The co-primary endpoints were the molecular diagnostic yield and the safety profile of US-guided lung biopsies. Results: From January 2021 to May 2024, 100 US-guided lung biopsies were carried out and 95 were considered for inclusion in the study. US-PLLB provided informative tissue for a histological evaluation in 93 of 95 patients with an overall diagnostic accuracy of 96.84% [Sensitivity: 92.63%; Specificity: 96.84%; PPV: 100%; NPV: 100%]. Sixty-Six patients were diagnosed with NSCLC (69.47%) and were considered for molecular diagnostic yield evaluation and PD-L1 testing. Four patients had malignant lymphoid lesions. US-PLLB was not adequate to achieve a final diagnosis in three patients (3.16%). Complete molecular profiling and PD-L1 evaluation were achieved in all patients with adenocarcinoma (molecular diagnostic yield: 100%). PD-L1 evaluation was achieved in 28 of 29 patients (96.55%) with either SCC or NOS lung cancer. The overall complication rate was 9.47% (n = 9). Six patients (6.31%) developed pneumothorax, while three patients (3.16%) suffered mild haemoptysis without desaturation. Conclusions: According to our findings, US-guided lung biopsy is a safe, minimally invasive procedure in patients with suspected lung malignancies, providing an excellent diagnostic yield for both comprehensive molecular profiling and PD-L1 testing. In addition, our results suggest that US-guided biopsy may also be an effective diagnostic approach in patients with suspected lung lymphoma.
引用
收藏
页数:12
相关论文
共 30 条
  • [1] Targeting immune checkpoints in non small cell lung cancer
    Bianco, Andrea
    Malapelle, Umberto
    Rocco, Danilo
    Perrotta, Fabio
    Mazzarella, Gennaro
    [J]. CURRENT OPINION IN PHARMACOLOGY, 2018, 40 : 46 - 50
  • [2] Brunese L, 2013, MED SCI MONITOR, V19, P95, DOI 1
  • [3] ULTRASONICALLY GUIDED PERCUTANEOUS BIOPSY OF PERIPHERAL PULMONARY MASSES
    CHANDRASEKHAR, AJ
    REYNES, CJ
    CHURCHILL, RJ
    [J]. CHEST, 1976, 70 (05) : 627 - 630
  • [4] New International Guidelines and Consensus on the Use of Lung Ultrasound
    Demi, Libertario
    Wolfram, Frank
    Klersy, Catherine
    De Silvestri, Annalisa
    Ferretti, Virginia Valeria
    Muller, Marie
    Miller, Douglas
    Feletti, Francesco
    Welnicki, Marcin
    Buda, Natalia
    Skoczylas, Agnieszka
    Pomiecko, Andrzej
    Damjanovic, Domagoj
    Olszewski, Robert
    Kirkpatrick, Andrew W.
    Breitkreutz, Raoul
    Mathis, Gebhart
    Soldati, Gino
    Smargiassi, Andrea
    Inchingolo, Riccardo
    Perrone, Tiziano
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (02) : 309 - 344
  • [5] Optimizing molecular testing of lung cancer needle biopsy specimens: potential solutions from an interdisciplinary qualitative study
    Fintelmann, Florian J.
    Martin, Nikki A.
    Tahir, Ismail
    Quinn, Elissa M.
    Allen, Timothy C.
    Joseph, Lija
    Nikolic, Boris
    Lee, Christopher
    [J]. RESPIRATORY RESEARCH, 2023, 24 (01)
  • [6] An Official American Thoracic Society/European Respiratory Society Statement: The Role of the Pulmonologist in the Diagnosis and Management of Lung Cancer
    Gaga, Mina
    Powell, Charles A.
    Schraufnagel, Dean E.
    Schoenfeld, Nicolas
    Rabe, Klaus
    Hill, Nicholas S.
    Sculier, Jean-Paul
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 188 (04) : 503 - 507
  • [7] ULTRASOUND-GUIDED PERCUTANEOUS NEEDLE BIOPSY FOR PERIPHERAL PULMONARY LESIONS: DIAGNOSTIC ACCURACY AND INFLUENCING FACTORS
    Guo, Yu-Qing
    Liao, Xin-Hong
    Li, Zhi-Xian
    Chen, Yuan-Yuan
    Wang, Si-Da
    Wang, Ji-Han
    Liao, Xian-Shan
    Luo, Yuan
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (05) : 1003 - 1011
  • [8] National guidelines for diagnosis and treatment of lung cancer 2022 in China (English version) National Health Commission of the People's Republic of China
    He, Jie
    Wu, Yilong
    Gao, Shugeng
    Wang, Jie
    Wang, Zhijie
    Wang, Jun
    Wang, Zhehai
    Wang, Lvhua
    Tian, Hui
    Bi, Nan
    Liu, Lunxu
    Xu, Lin
    Li, Hecheng
    Wu, Ning
    He, Jianxing
    Ying, Jianming
    Song, Qibin
    Zhang, Li
    Zhang, Lanjun
    Lu, Shun
    Chen, Ming
    Chen, Haiquan
    Fan, Yun
    Zhou, Caicun
    Zhao, Lujun
    Gao, Yushun
    Huang, Yunchao
    Huang, Cheng
    Ge, Hong
    Cheng, Ying
    Fu, Xiaolong
    Tan, Fengwei
    Xue, Qi
    [J]. CHINESE JOURNAL OF CANCER RESEARCH, 2022, 34 (03) : 176 - 206
  • [9] Hendriks LE, 2023, ANN ONCOL, V34, P339, DOI 10.1016/j.annonc.2022.12.009
  • [10] Diagnostic Accuracy of Ultrasound Guided Percutaneous Pleural Needle Biopsy for Malignant Pleural Mesothelioma
    Iadevaia, Carlo
    D'Agnano, Vito
    Pagliaro, Raffaella
    Nappi, Felice
    Lucci, Raffaella
    Massa, Simona
    Bianco, Andrea
    Perrotta, Fabio
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (09)